Pupillographic evaluation of relative afferent pupillary defect in glaucoma patients.

Naoki Ozeki1, Kenya Yuki, Daisuke Shiba, Kazuo Tsubota.   

Abstract

AIM: To evaluate the association between the magnitude of relative afferent pupillary defect (RAPD) and the laterality of visual fields in glaucoma patients using pupillography.
METHODS: Evaluations were made with an RAPDx (Konan Medical USA, Irvine, California, USA), which is designed to analyse pupil responses to multiple colour stimuli (white, red, green, blue, and yellow) at multiple controlled stimulus intensities. Humphrey automated perimetry (SITA standard 30-2) was performed to determine mean deviations (MDs), which were used to evaluate associations between MD differences (better eye MD-worse eye MD) and RAPDx amplitude and latency measurements in pupil response to multiple colour stimuli.
RESULTS: 58 glaucoma patients (35 men, 23 women; mean age: 62.6±12.8 years; range 28-88 years) were enrolled. The MD values were -2.00±3.1 (range -9.64 to 2.33) dB in the better eyes and -8.17±7.1 (range -26.33 to 1.07) dB in the worse eyes. The differences in MD values (better eye MD-worse eye MD) were 6.17±6.1 (range 0.05-26.41) dB. The results of linear regression analysis between the log-scaled RAPD amplitudes and differences in MD values were as follows: white: R(2)=0.45 (p<0.001), red: R(2)=0.18 (p=0.002), green: R(2)=0.30 (p<0.001), blue: R(2)=0.29 (p<0.001), and yellow: R(2)=0.32 (p<0.001). The log-scaled RAPD latencies and the differences in MD values were: white: R(2)=0.17 (p=0.001), red: R(2)=0.03 (p=0.22), green: R(2)=0.01 (p=0.52), blue: R(2)=0.1 (p=0.02), and yellow: R(2)=0.05 (p=0.11).
CONCLUSIONS: The log-scaled RAPD amplitudes correlated moderately with the differences in MD values, but the log-scaled RAPD latencies showed a weaker correlation. Stimulation with white light produced the strongest correlation with differences in MD values.

Entities:  

Keywords:  Field of vision; Glaucoma; Optic Nerve; Pupil

Mesh:

Year:  2013        PMID: 24064937     DOI: 10.1136/bjophthalmol-2013-303825

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  8 in total

1.  Evaluation of Relative Afferent Pupillary Defect Using RAPDx Device in Patients with Optic Nerve Disease.

Authors:  Tsukasa Satou; Hitoshi Ishikawa; Ken Asakawa; Toshiaki Goseki; Takahiro Niida; Kimiya Shimizu
Journal:  Neuroophthalmology       Date:  2016-04-14

2.  Effects of Age and Sex on Values Obtained by RAPDx® Pupillometer, and Determined the Standard Values for Detecting Relative Afferent Pupillary Defect.

Authors:  Tsukasa Satou; Toshiaki Goseki; Ken Asakawa; Hitoshi Ishikawa; Kimiya Shimizu
Journal:  Transl Vis Sci Technol       Date:  2016-04-28       Impact factor: 3.283

3.  Association between a relative afferent pupillary defect using pupillography and inner retinal atrophy in optic nerve disease.

Authors:  Go Takizawa; Atsushi Miki; Fumiatsu Maeda; Katsutoshi Goto; Syunsuke Araki; Yoshiaki Ieki; Junichi Kiryu; Kiyoshi Yaoeda
Journal:  Clin Ophthalmol       Date:  2015-10-09

4.  Relative Afferent Pupillary Defects in Homonymous Visual Field Defects Caused by Stroke of the Occipital Lobe Using Pupillometer.

Authors:  Go Takizawa; Atsushi Miki; Fumiatsu Maeda; Katsutoshi Goto; Syunsuke Araki; Tsutomu Yamashita; Yoshiaki Ieki; Junichi Kiryu; Kiyoshi Yaoeda
Journal:  Neuroophthalmology       Date:  2017-08-31

Review 5.  Standards in Pupillography.

Authors:  Carina Kelbsch; Torsten Strasser; Yanjun Chen; Beatrix Feigl; Paul D Gamlin; Randy Kardon; Tobias Peters; Kathryn A Roecklein; Stuart R Steinhauer; Elemer Szabadi; Andrew J Zele; Helmut Wilhelm; Barbara J Wilhelm
Journal:  Front Neurol       Date:  2019-02-22       Impact factor: 4.003

6.  Quantification of relative afferent pupillary defect by an automated pupillometer and its relationship with visual acuity and dimensions of macular lesions in age-related macular degeneration.

Authors:  Renu P Rajan; Amit K Deb; Sonali Lomte; Claudio M Privitera; Naresh B Kannan; Kim Ramasamy; Ravilla D Ravindran
Journal:  Indian J Ophthalmol       Date:  2021-10       Impact factor: 1.848

7.  Asymmetric Macular Structural Damage Is Associated With Relative Afferent Pupillary Defects in Patients With Glaucoma.

Authors:  Carolina P B Gracitelli; Andrew J Tatham; Linda M Zangwill; Robert N Weinreb; Ricardo Y Abe; Alberto Diniz-Filho; Augusto Paranhos; Saif Baig; Felipe A Medeiros
Journal:  Invest Ophthalmol Vis Sci       Date:  2016-04       Impact factor: 4.799

8.  Cross-sectional pupillographic evaluation of relative afferent pupillary defect in age-related macular degeneration.

Authors:  Kei Takayama; Yasuki Ito; Hiroki Kaneko; Yosuke Nagasaka; Taichi Tsunekawa; Tadasu Sugita; Hiroko Terasaki
Journal:  Medicine (Baltimore)       Date:  2016-09       Impact factor: 1.889

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.