Literature DB >> 24064426

Natural history of optical coherence tomography-detected non-flow-limiting edge dissections following drug-eluting stent implantation.

Maria D Radu1, Lorenz Räber, Jungho Heo, Bill D Gogas, Erik Jørgensen, Henning Kelbæk, Takashi Muramatsu, Vasim Farooq, Steffen Helqvist, Hector M Garcia-Garcia, Stephan Windecker, Kari Saunamäki, Patrick W Serruys.   

Abstract

AIMS: Angiographic evidence of edge dissections has been associated with a risk of early stent thrombosis. Optical coherence tomography (OCT) is a high-resolution technology detecting a greater number of edge dissections--particularly non-flow-limiting--compared to angiography. Their natural history and clinical implications remain unclear. The objectives of the present study were to assess the morphology, healing response, and clinical outcomes of OCT-detected edge dissections using serial OCT imaging at baseline and at one year following drug-eluting stent (DES) implantation. METHODS AND
RESULTS: Edge dissections were defined as disruptions of the luminal surface in the 5 mm segments proximal and distal to the stent, and categorised as flaps, cavities, double-lumen dissections or fissures. Qualitative and quantitative OCT analyses were performed every 0.5 mm at baseline and one year, and clinical outcomes were assessed. Sixty-three lesions (57 patients) were studied with OCT at baseline and one-year follow-up. Twenty-two non-flow-limiting edge dissections in 21 lesions (20 patients) were identified by OCT; only two (9%) were angiographically visible. Flaps were found in 96% of cases. The median longitudinal dissection length was 2.9 mm (interquartile range [IQR] 1.6-4.2 mm), whereas the circumferential and axial extensions amounted to 1.2 mm (IQR: 0.9-1.7 mm) and 0.6 mm (IQR: 0.4-0.7 mm), respectively. Dissections extended into the media and adventitia in seven (33%) and four (20%) cases, respectively. Eighteen (82%) OCT-detected edge dissections were also evaluated with intravascular ultrasound which identified nine (50%) of these OCT-detected dissections. No stent thrombosis or target lesion revascularisation occurred up to one year. At follow-up, 20 (90%) edge dissections were completely healed on OCT. The two cases exhibiting persistent dissection had the longest flaps (2.81 mm and 2.42 mm) at baseline.
CONCLUSIONS: OCT-detected edge dissections which are angiographically silent in the majority of cases are not associated with acute stent thrombosis or restenosis up to one-year follow-up.

Entities:  

Mesh:

Year:  2014        PMID: 24064426     DOI: 10.4244/EIJV9I9A183

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  13 in total

1.  The influence of coronary plaque morphology assessed by optical coherence tomography on final microvascular function after stenting in patients with ST-elevation myocardial infarction.

Authors:  Giovanni L De Maria; Niket Patel; Mathias Wolfrum; Gregor Fahrni; George Kassimis; Italo Porto; Sam Dawkins; Robin P Choudhury; John C Forfar; Bernard D Prendergast; Keith M Channon; Rajesh K Kharbanda; Hector M Garcia-Garcia; Adrian P Banning
Journal:  Coron Artery Dis       Date:  2017-05       Impact factor: 1.439

2.  Coronary stent thrombosis: what have we learned?

Authors:  Carlos Collet; Yohei Sotomi; Rafael Cavalcante; Pannipa Suwannasom; Erhan Tenekecioglu; Yoshinobu Onuma; Patrick W Serruys
Journal:  J Thorac Dis       Date:  2016-07       Impact factor: 2.895

Review 3.  A Practical Approach to Assessing Stent Results with IVUS or OCT.

Authors:  Daisuke Hachinohe; Satoru Mitomo; Luciano Candilio; Azeem Latib
Journal:  Methodist Debakey Cardiovasc J       Date:  2018 Jan-Mar

4.  Post-stenting angiographically silent coronary dissection: OCT comes to the rescue.

Authors:  Roopali Khanna; Anindya Ghosh; Ankit Kumar Sahu; Pravin K Goel
Journal:  Br J Cardiol       Date:  2021-09-01

Review 5.  Optical coherence tomography in coronary atherosclerosis assessment and intervention.

Authors:  Makoto Araki; Seung-Jung Park; Harold L Dauerman; Shiro Uemura; Jung-Sun Kim; Carlo Di Mario; Thomas W Johnson; Giulio Guagliumi; Adnan Kastrati; Michael Joner; Niels Ramsing Holm; Fernando Alfonso; William Wijns; Tom Adriaenssens; Holger Nef; Gilles Rioufol; Nicolas Amabile; Geraud Souteyrand; Nicolas Meneveau; Edouard Gerbaud; Maksymilian P Opolski; Nieves Gonzalo; Guillermo J Tearney; Brett Bouma; Aaron D Aguirre; Gary S Mintz; Gregg W Stone; Christos V Bourantas; Lorenz Räber; Sebastiano Gili; Kyoichi Mizuno; Shigeki Kimura; Toshiro Shinke; Myeong-Ki Hong; Yangsoo Jang; Jin Man Cho; Bryan P Yan; Italo Porto; Giampaolo Niccoli; Rocco A Montone; Vikas Thondapu; Michail I Papafaklis; Lampros K Michalis; Harmony Reynolds; Jacqueline Saw; Peter Libby; Giora Weisz; Mario Iannaccone; Tommaso Gori; Konstantinos Toutouzas; Taishi Yonetsu; Yoshiyasu Minami; Masamichi Takano; O Christopher Raffel; Osamu Kurihara; Tsunenari Soeda; Tomoyo Sugiyama; Hyung Oh Kim; Tetsumin Lee; Takumi Higuma; Akihiro Nakajima; Erika Yamamoto; Krzysztof L Bryniarski; Luca Di Vito; Rocco Vergallo; Francesco Fracassi; Michele Russo; Lena M Seegers; Iris McNulty; Sangjoon Park; Marc Feldman; Javier Escaned; Francesco Prati; Eloisa Arbustini; Fausto J Pinto; Ron Waksman; Hector M Garcia-Garcia; Akiko Maehara; Ziad Ali; Aloke V Finn; Renu Virmani; Annapoorna S Kini; Joost Daemen; Teruyoshi Kume; Kiyoshi Hibi; Atsushi Tanaka; Takashi Akasaka; Takashi Kubo; Satoshi Yasuda; Kevin Croce; Juan F Granada; Amir Lerman; Abhiram Prasad; Evelyn Regar; Yoshihiko Saito; Mullasari Ajit Sankardas; Vijayakumar Subban; Neil J Weissman; Yundai Chen; Bo Yu; Stephen J Nicholls; Peter Barlis; Nick E J West; Armin Arbab-Zadeh; Jong Chul Ye; Jouke Dijkstra; Hang Lee; Jagat Narula; Filippo Crea; Sunao Nakamura; Tsunekazu Kakuta; James Fujimoto; Valentin Fuster; Ik-Kyung Jang
Journal:  Nat Rev Cardiol       Date:  2022-04-21       Impact factor: 49.421

Review 6.  Optical Coherence Tomography of the Coronary Arteries.

Authors:  Robert Roland; Josef Veselka
Journal:  Int J Angiol       Date:  2021-02-12

7.  CVIT expert consensus document on primary percutaneous coronary intervention (PCI) for acute myocardial infarction (AMI) in 2018.

Authors:  Yukio Ozaki; Yuki Katagiri; Yoshinobu Onuma; Tetsuya Amano; Takashi Muramatsu; Ken Kozuma; Satoru Otsuji; Takafumi Ueno; Nobuo Shiode; Kazuya Kawai; Nobuhiro Tanaka; Kinzo Ueda; Takashi Akasaka; Keiichi Igarashi Hanaoka; Shiro Uemura; Hirotaka Oda; Yoshiaki Katahira; Kazushige Kadota; Eisho Kyo; Katsuhiko Sato; Tadaya Sato; Junya Shite; Koichi Nakao; Masami Nishino; Yutaka Hikichi; Junko Honye; Tetsuo Matsubara; Sumio Mizuno; Toshiya Muramatsu; Taku Inohara; Shun Kohsaka; Ichiro Michishita; Hiroyoshi Yokoi; Patrick W Serruys; Yuji Ikari; Masato Nakamura
Journal:  Cardiovasc Interv Ther       Date:  2018-03-29

Review 8.  CVIT expert consensus document on primary percutaneous coronary intervention (PCI) for acute myocardial infarction (AMI) update 2022.

Authors:  Yukio Ozaki; Hironori Hara; Yoshinobu Onuma; Yuki Katagiri; Tetsuya Amano; Yoshio Kobayashi; Takashi Muramatsu; Hideki Ishii; Ken Kozuma; Nobuhiro Tanaka; Hitoshi Matsuo; Shiro Uemura; Kazushige Kadota; Yutaka Hikichi; Kenichi Tsujita; Junya Ako; Yoshihisa Nakagawa; Yoshihiro Morino; Ichiro Hamanaka; Nobuo Shiode; Junya Shite; Junko Honye; Tetsuo Matsubara; Kazuya Kawai; Yasumi Igarashi; Atsunori Okamura; Takayuki Ogawa; Yoshisato Shibata; Takafumi Tsuji; Junji Yajima; Kaoru Iwabuchi; Nobuo Komatsu; Teruyasu Sugano; Masaru Yamaki; Shinichiro Yamada; Hiroaki Hirase; Yuusuke Miyashita; Fuminobu Yoshimachi; Masakazu Kobayashi; Jiro Aoki; Hirotaka Oda; Yoshiaki Katahira; Kinzo Ueda; Masami Nishino; Koichi Nakao; Ichiro Michishita; Takafumi Ueno; Taku Inohara; Shun Kohsaka; Tevfik F Ismail; Patrick W Serruys; Masato Nakamura; Hiroyoshi Yokoi; Yuji Ikari
Journal:  Cardiovasc Interv Ther       Date:  2022-01-12

9.  Impact of stent edge dissection detected by optical coherence tomography after current-generation drug-eluting stent implantation.

Authors:  Hiroyuki Jinnouchi; Kenichi Sakakura; Tomonobu Yanase; Yusuke Ugata; Takunori Tsukui; Yosuke Taniguchi; Kei Yamamoto; Masaru Seguchi; Hiroshi Wada; Hideo Fujita
Journal:  PLoS One       Date:  2021-11-04       Impact factor: 3.240

10.  Comparison Between Optical Frequency Domain Imaging and Intravascular Ultrasound for Percutaneous Coronary Intervention Guidance in Biolimus A9-Eluting Stent Implantation: A Randomized MISTIC-1 Non-Inferiority Trial.

Authors:  Takashi Muramatsu; Yukio Ozaki; Mamoru Nanasato; Masato Ishikawa; Ryo Nagasaka; Masaya Ohota; Yosuke Hashimoto; Yu Yoshiki; Hidemaro Takatsu; Katsuyoshi Ito; Hiroki Kamiya; Yukihiko Yoshida; Toyoaki Murohara; Hideo Izawa
Journal:  Circ Cardiovasc Interv       Date:  2020-10-27       Impact factor: 6.546