Literature DB >> 24060210

Assessing the reproducibility of the IOTA simple ultrasound rules for classifying adnexal masses as benign or malignant using stored 3D volumes.

Stefano Guerriero1, Luca Saba, Silvia Ajossa, Cristina Peddes, Federica Sedda, Alessandra Piras, Begoña Olartecoechea, María Aubá, Juan Luis Alcázar.   

Abstract

OBJECTIVE: To analyze the reproducibility of the IOTA simple ultrasound rules for classifying adnexal masses as benign or malignant among examiners with different level of expertise using stored 3D volumes of adnexal masses. STUDY
DESIGN: Five examiners, with different levels of experience and blinded to each other, evaluated 100 stored 3D volumes from adnexal masses and looked for the presence or absence of malignant or benign features according to the IOTA definitions. Multiplanar view and virtual navigation were used. All examiners had to assess the 3D volume of each adnexal mass and classify it as benign or malignant. To analyze intra-observer agreement each examiner performed the assessment twice with a two-week interval between the first and second assessments. To analyze the inter-observer agreement, the second assessment from each examiner was used. Reproducibility was assessed calculating the weighted Kappa index.
RESULTS: Intra-observer reproducibility was moderate or good for all observers (Kappa index ranging from 0.59 to 0.74). Inter-observer reproducibility was moderate to good (Kappa index range: 0.46-0.67).
CONCLUSIONS: The simple rules are reasonably reproducible among observers with different level of expertise when assessed in stored 3D volumes.
Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

Keywords:  Adnexal mass; Diagnosis; Reproducibility; Three-dimensional ultrasound

Mesh:

Year:  2013        PMID: 24060210     DOI: 10.1016/j.ejogrb.2013.08.031

Source DB:  PubMed          Journal:  Eur J Obstet Gynecol Reprod Biol        ISSN: 0301-2115            Impact factor:   2.435


  4 in total

Review 1.  Role of Three-Dimensional Ultrasound in Gynecology.

Authors:  Engin Turkgeldi; Bulent Urman; Baris Ata
Journal:  J Obstet Gynaecol India       Date:  2014-11-08

2.  IOTA Simple Ultrasound Rules for Triage of Adnexal Mass: Experience from South India.

Authors:  Jyothi Shetty; Aruna Saradha; Deeksha Pandey; Rajeshwari Bhat; Sunanda Bharatnur
Journal:  J Obstet Gynaecol India       Date:  2019-05-03

3.  The Reproducibility of Ultrasonographic Findings of Rectosigmoid Endometriosis Among Examiners With Different Level of Expertise.

Authors:  Stefano Guerriero; MariaAngela Pascual; Silvia Ajossa; Manuela Neri; Monica Pilloni; Betlem Graupera; Ignacio Rodriguez; Juan Luis Alcazar
Journal:  J Ultrasound Med       Date:  2021-04-10       Impact factor: 2.754

4.  Predicting Malignancy in Adnexal Masses by the International Ovarian Tumor Analysis-Simple Rules.

Authors:  Vrushti Solanki; Pratibha Singh; Charu Sharma; Navdeep Ghuman; Binit Sureka; Shashank Shekhar; Meenakshi Gothwal; Garima Yadav
Journal:  J Midlife Health       Date:  2021-01-21
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.