Literature DB >> 24059021

The accuracy of IOL power calculation formulas for eyes of axial length exceeding 24.5 mm.

Wiktor Stopyra1.   

Abstract

PURPOSE: To compare the accuracy of different IOL power calculation formulas for eyes of axial length exceeding 24.5 mm.
MATERIAL AND METHODS: 61 patients were examined, whose ocular axial lenght ranged between 24.51 mm and 26.72 mm. Preoperatively, the IOL power for each patient was calculated using six different formulas (SRK II, SRK/T, Binkhorst, Hoffer Q, Holladay 1, and Haigis). The power of the actually implanted IOL was based on Holladay 1 formula. Visual acuity was measured using Snellen chart on the 30th postoperative day.
RESULTS: 54 patients (88.5%) achieved full visual acuity (1.0 on Snellen chart) after cataract surgery. If other power calculation formulas were used for the actual IOL, this would be achieved respectively in: SRK/T - 39 patients (63.9%), Hoffer O - 22 patients (36.1%), Binkhorst - 21 patients (34.4%), Haigis - 7 patients (11.5%), SRK II - 5 patients (8.2%).
CONCLUSIONS: 1. Holladay 1 formula is recommended for intraocular lens power calculation for eyes of axial length exceeding 24.5 mm. 2. SRK/T formula also seems to be satisfactory for these cases.

Entities:  

Mesh:

Year:  2013        PMID: 24059021

Source DB:  PubMed          Journal:  Klin Oczna        ISSN: 0023-2157


  6 in total

1.  Respond to: A study regarding efficacy of various intraocular lens power calculation formulas in a subset of Indian myopic population.

Authors:  Ashish Mitra; Elesh Jain; Alok Sen; Shubhi Tripathi
Journal:  Indian J Ophthalmol       Date:  2015-03       Impact factor: 1.848

2.  Accuracy of axial length measurements from immersion B-scan ultrasonography in highly myopic eyes.

Authors:  Qing-Hua Yang; Bing Chen; Guang-Hua Peng; Zhao-Hui Li; Yi-Fei Huang
Journal:  Int J Ophthalmol       Date:  2014-06-18       Impact factor: 1.779

3.  Comparison axial length measurements from three biometric instruments in high myopia.

Authors:  Xiao-Gang Wang; Jing Dong; Yu-Lan Pu; Hui-Jun Liu; Qiang Wu
Journal:  Int J Ophthalmol       Date:  2016-06-18       Impact factor: 1.779

4.  Changes in the Ocular Parameters of Patients with Graves' Disease after Antithyroid Drug Treatment.

Authors:  Je-Sang Lee; Dong-Ju Yeom; Seung-Kwan Nah; Bo-Yeon Kim; Sun-Young Jang
Journal:  Medicina (Kaunas)       Date:  2021-04-25       Impact factor: 2.430

5.  A study regarding efficacy of various intraocular lens power calculation formulas in a subset of Indian myopic population.

Authors:  Ashish Mitra; Elesh Jain; Alok Sen; Shubhi Tripathi
Journal:  Indian J Ophthalmol       Date:  2014-07       Impact factor: 1.848

6.  Comparison of Ocular Biometry Using New Swept-source Optical Coherence Tomography-based Optical Biometer with Other Devices.

Authors:  Young Joo Cho; Tae Hyung Lim; Kee Yong Choi; Beom Jin Cho
Journal:  Korean J Ophthalmol       Date:  2018-08
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.