Literature DB >> 24054852

Correlation of optic nerve sheath diameter measurements by computed tomography and magnetic resonance imaging.

Hossein Kalantari1, Rajnish Jaiswal, Isaac Bruck, Hussein Matari, Farzaneh Ghobadi, Jeremy Weedon, Getaw Worku Hassen.   

Abstract

BACKGROUND: Traditionally, intracranial pressure is measured by direct ventriculostomy, which is invasive. Noninvasive measures such as bedside ultrasound and magnetic resonance imaging have been advocated and utilized recently to assess the intracranial pressure. The role of this study is to determine the degree of agreement between measurements of the optic nerve sheath diameter by computed tomography (CT) and magnetic resonance imaging (MRI).
MATERIALS AND METHODS: Retrospective chart review of 100 consecutive patients who had both MRI and CT scan of the head from January 1, 2011, until March 31, 2013, at our center was performed. A discrepancy of 0.2 mm between the 2 measurements was set as acceptable difference. The measurements of optic nerve sheath diameter (ONSD) were compared for agreement between the 2 modalities using the method by Bland and Altman.
RESULTS: A total of 100 patients with both MRI and CT scan of the head were selected. Of these 100 patients, 24 were male and 76 were female. The average age was 63 years. No ONSD abnormality was detected in any of the patients. The discrepancy in measurements of the ONSD between CT and MRI in transverse plane was less than the predetermined cut-off value of 0.2 mm. Within-subject variance was estimated at 0.0058 for both CT and MRI.
CONCLUSION: Comparable results without significant discrepancy as predetermined by the study groups were obtained from CT scan. Measurement of ONSD by CT scan can be used to indirectly asses the intracranial pressure in addition to clinical assessment and other signs of increased intracranial pressure on CT scan.
© 2013.

Entities:  

Mesh:

Year:  2013        PMID: 24054852     DOI: 10.1016/j.ajem.2013.07.028

Source DB:  PubMed          Journal:  Am J Emerg Med        ISSN: 0735-6757            Impact factor:   2.469


  12 in total

Review 1.  Noninvasive methods of detecting increased intracranial pressure.

Authors:  Wen Xu; Patrick Gerety; Tomas Aleman; Jordan Swanson; Jesse Taylor
Journal:  Childs Nerv Syst       Date:  2016-06-28       Impact factor: 1.475

2.  Use of neuroimaging measurements of optic nerve sheath diameter to assess intracranial pressure in craniosynostosis.

Authors:  Mostafa Haredy; Giulio Zuccoli; Mandeep Tamber; Amani Davis; Ken Nischal; Jesse A Goldstein
Journal:  Childs Nerv Syst       Date:  2018-01-29       Impact factor: 1.475

3.  Serial Optic Nerve Sheath Diameter via Radiographic Imaging: Correlation With ICP and Outcomes.

Authors:  Diane McLaughlin; Lisa Anderson; Jinhong Guo; Molly McNett
Journal:  Neurol Clin Pract       Date:  2021-10

4.  Optic Nerve Measurement on MRI in the Pediatric Population: Normative Values and Correlations.

Authors:  C E Al-Haddad; M G Sebaaly; R N Tutunji; C J Mehanna; S R Saaybi; A M Khamis; R G Hourani
Journal:  AJNR Am J Neuroradiol       Date:  2017-12-07       Impact factor: 3.825

5.  Correlating optic nerve sheath diameter with opening intracranial pressure in pediatric traumatic brain injury.

Authors:  Adam M H Young; Mathew R Guilfoyle; Joseph Donnelly; Daniel Scoffings; Helen Fernandes; Mathew Garnett; Shruti Agrawal; Peter J Hutchinson
Journal:  Pediatr Res       Date:  2016-08-11       Impact factor: 3.756

6.  Comment on 'Neuroradiology for ophthalmologists'.

Authors:  Ankit Sinha; Victoria Nowak; Fion Bremner
Journal:  Eye (Lond)       Date:  2021-04-06       Impact factor: 3.775

7.  Optic nerve sheath diameter on computed tomography is correlated with simultaneously measured intracranial pressure in patients with severe traumatic brain injury.

Authors:  Mypinder S Sekhon; Donald E Griesdale; Chiara Robba; Nick McGlashan; Edward Needham; Katherine Walland; Alyssa C Shook; Peter Smielewski; Marek Czosnyka; Arun K Gupta; David K Menon
Journal:  Intensive Care Med       Date:  2014-07-18       Impact factor: 17.440

8.  Computed tomography imaging-based normative orbital measurement in Indian population.

Authors:  Vivek Gupta; Anuj Prabhakar; Mukesh Yadav; Niranjan Khandelwal
Journal:  Indian J Ophthalmol       Date:  2019-05       Impact factor: 1.848

9.  Diagnostic Accuracy of Optic Nerve Ultrasonography and Ophthalmoscopy in Prediction of Elevated Intracranial Pressure.

Authors:  Keihan Golshani; Mehdi Ebrahim Zadeh; Ziba Farajzadegan; Fariborz Khorvash
Journal:  Emerg (Tehran)       Date:  2015

10.  Assessment of intracranial pressure with ultrasonographic retrobulbar optic nerve sheath diameter measurement.

Authors:  Dachuan Liu; Zhen Li; Xuxiang Zhang; Liping Zhao; Jianping Jia; Fei Sun; Yaxing Wang; Daqing Ma; Wenbin Wei
Journal:  BMC Neurol       Date:  2017-09-29       Impact factor: 2.474

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.