Sequential injection system for simultaneous determination of sucrose and phosphate in cola drinks using paired emitter-detector diode sensor.

Phoonthawee Saetear1, Kittiwut Khamtau, Nuanlaor Ratanawimarnwong, Kamonthip Sereenonchai, Duangjai Nacapricha.   

Abstract

This work presents the simultaneous determination of sucrose and phosphate by using sequential injection (SI) system with a low cost paired emitter-detector diode (PEDD) light sensor. The PEDD uses two 890 nm LEDs. Measurement of sucrose in Brix unit was carried out based on the detection of light refraction occurring at the liquid interface (the schlieren effect) between the sucrose solution and water. Phosphate was measured from the formation of calcium phosphate with turbidimetric detection. With careful design of the loading sequence and volume (sample--precipitating reagent--sample), simultaneous detection of sucrose and phosphate was accomplished with the single PEDD detector. At the optimized condition, linear calibrations from 1 to 7 Brix sucrose and from 50 to 200mg PO4(3-)L(-1) were obtained. Good precision at lower than 2% RSD (n=10) for both analytes with satisfactory throughput of 21 injections h(-1) was achieved. The method was successfully applied for the determination of sucrose and phosphate in cola drinks. The proposed method is readily applicable for automation and is found to be an alternative method to conventional procedures for on-line quality control process in cola drink industry. Crown
Copyright © 2013. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cola drinks; Paired emitter-detector diode (PEDD); Phosphate; Schlieren effect; Sucrose; Turbidimetry

Mesh:

Substances:

Year:  2013        PMID: 24054603     DOI: 10.1016/j.talanta.2013.05.051

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  Towards optoelectronic urea biosensors.

Authors:  Marta Pokrzywnicka; Robert Koncki; Łukasz Tymecki
Journal:  Anal Bioanal Chem       Date:  2015-01-27       Impact factor: 4.142

2.  A novel automatic flow method with direct-injection photometric detector for determination of dissolved reactive phosphorus in wastewater and freshwater samples.

Authors:  Stanislawa Koronkiewicz; Mihaela Trifescu; Lech Smoczynski; Harsha Ratnaweera; Slawomir Kalinowski
Journal:  Environ Monit Assess       Date:  2018-02-12       Impact factor: 2.513

3.  Sequential Injection System for Analysis of Degree Brix, Orthophosphate and pH in Raw Sugarcane Juice Applicable to Sugar Industry.

Authors:  Phoonthawee Saetear; Nattinee Saechua; Kamonthip Sereenonchai
Journal:  Molecules       Date:  2021-10-27       Impact factor: 4.411

4.  Dual-Purpose Photometric-Conductivity Detector for Simultaneous and Sequential Measurements in Flow Analysis.

Authors:  Thitirat Mantim; Korbua Chaisiwamongkhol; Kanchana Uraisin; Peter C Hauser; Prapin Wilairat; Duangjai Nacapricha
Journal:  Molecules       Date:  2020-05-13       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.