Triple rule-out computed tomographic angiography for chest pain: a diagnostic systematic review and meta-analysis.

David Ayaram1, M Fernanda Bellolio, M Hassan Murad, Torrey A Laack, Annie T Sadosty, Patricia J Erwin, Judd E Hollander, Victor M Montori, Ian G Stiell, Erik P Hess.   

Abstract

OBJECTIVES: The objective was to compare the image quality, diagnostic accuracy, radiation exposure, and contrast volume of "triple rule-out" (TRO) computed tomography (CT) to other diagnostic modalities commonly used to evaluate patients with nontraumatic chest pain (dedicated coronary, pulmonary embolism [PE], and aortic dissection CT; invasive coronary angiography; and nuclear stress testing).
METHODS: Four electronic databases were searched, along with reference lists and contacted content experts, for relevant studies from inception until October 2012. Eligible studies enrolled patients with nontraumatic chest pain, shortness of breath, suspected acute coronary syndrome (ACS), PE, or aortic dissection; used at least 64-slice CT technology; and compared TRO CT to another diagnostic modality.
RESULTS: Eleven studies enrolling 3,539 patients (791 TRO and 2,748 non-TRO) were included (one randomized controlled trial and 10 observational). There was no significant difference in image quality between TRO and dedicated CT scans. TRO CT had the following pooled diagnostic accuracy estimates for coronary artery disease: sensitivity of 94.3% (95% confidence interval [CI] = 89.1% to 97.5%), specificity of 97.4% (95% CI = 96.1% to 98.4%), positive likelihood ratio (LR+) of 17.71 (95% CI = 3.92 to 79.96), and negative likelihood ratio (LR-) of 0.08 (95% CI = 0.02 to 0.27). There were insufficient numbers of patients with PE or aortic dissection to generate diagnostic accuracy estimates for these conditions. Use of TRO CT involved greater radiation exposure (mean difference [MD] = 4.84 mSv, 95% CI = 1.65 to 8.04 mSv) and contrast exposure (MD = 38.0 mL, 95% CI = 28.1 to 48.0 mL) compared to non-TRO CT patients.
CONCLUSIONS: Triple rule-out CT is highly accurate for detecting coronary artery disease. Given the low (<1%) prevalence of PE and aortic dissection in the included studies, and the increased radiation and contrast exposure, there are insufficient data to recommend use of TRO CT in the diagnosis of these conditions.
© 2013 by the Society for Academic Emergency Medicine.

Entities:  

Mesh:

Year:  2013        PMID: 24050793     DOI: 10.1111/acem.12210

Source DB:  PubMed          Journal:  Acad Emerg Med        ISSN: 1069-6563            Impact factor:   3.451


  15 in total

Review 1.  Diagnosis and management of acute aortic syndromes: dissection, intramural hematoma, and penetrating aortic ulcer.

Authors:  Marc P Bonaca; Patrick T O'Gara
Journal:  Curr Cardiol Rep       Date:  2014       Impact factor: 2.931

Review 2.  Chest pain: coronary CT in the ER.

Authors:  Erica Maffei; Sara Seitun; Andrea I Guaricci; Filippo Cademartiri
Journal:  Br J Radiol       Date:  2016-02-11       Impact factor: 3.039

Review 3.  Imaging the posterior mediastinum: a multimodality approach.

Authors:  Mariaelena Occhipinti; Benedikt H Heidinger; Elisa Franquet; Ronald L Eisenberg; Alexander A Bankier
Journal:  Diagn Interv Radiol       Date:  2015 Jul-Aug       Impact factor: 2.630

4.  Triple-rule-out CT angiography using two axial scans with 16 cm wide-detector for radiation dose reduction.

Authors:  Yuhuan Chen; Qi Wang; Jianying Li; Yongjun Jia; Qi Yang; Taiping He
Journal:  Eur Radiol       Date:  2018-05-22       Impact factor: 5.315

5.  Machine learning-based CT fractional flow reserve assessment in acute chest pain: first experience.

Authors:  Matthias Eberhard; Tin Nadarevic; Andrej Cousin; Jochen von Spiczak; Ricarda Hinzpeter; Andre Euler; Fabian Morsbach; Robert Manka; Dagmar I Keller; Hatem Alkadhi
Journal:  Cardiovasc Diagn Ther       Date:  2020-08

6.  Lex parsimoniae.

Authors:  Avadhesh Saraswat; Seshasayee Narasimhan
Journal:  J Cardiol Cases       Date:  2017-03-11

7.  Dual-phase computed tomography imaging in acute chest pain: emerging protocols and potential future implications.

Authors:  Mahdi Saleh; Timothy C Tan
Journal:  Eur Heart J Case Rep       Date:  2021-05-09

8.  The triple rule out CT in acute chest pain: a challenge for emergency radiologists?

Authors:  Vincenzo Russo; Camilla Sportoletti; Giulia Scalas; Domenico Attinà; Francesco Buia; Fabio Niro; Cecilia Modolon; Carlo De Luca; Francesco Monteduro; Luigi Lovato
Journal:  Emerg Radiol       Date:  2021-02-18

9.  Chest Pain of Uncertain Aetiology: Role of Contrast Enhanced Computed Tomography in the Emergency Department.

Authors:  Firas Yassin; Chris Sawh; Pankaj Garg
Journal:  Open Cardiovasc Med J       Date:  2016-09-30

10.  Triple Rule Out versus CT Angiogram Plus Stress Test for Evaluation of Chest Pain in the Emergency Department.

Authors:  Kelly N Sawyer; Payal Shah; Lihua Qu; Michael C Kurz; Carol L Clark; Robert A Swor
Journal:  West J Emerg Med       Date:  2015-10-20