Literature DB >> 24046483

Correlation of embryonic skeletal muscle myotube physical characteristics with contractile force generation on an atomic force microscope-based bio-microelectromechanical systems device.

K L Pirozzi1, C J Long, C W McAleer, A S T Smith, J J Hickman.   

Abstract

Rigorous analysis of muscle function in in vitro systems is needed for both acute and chronic biomedical applications. Forces generated by skeletal myotubes on bio-microelectromechanical cantilevers were calculated using a modified version of Stoney's thin-film equation and finite element analysis (FEA), then analyzed for regression to physical parameters. The Stoney's equation results closely matched the more intensive FEA and the force correlated to cross-sectional area (CSA). Normalizing force to measured CSA significantly improved the statistical sensitivity and now allows for close comparison of in vitro data to in vivo measurements for applications in exercise physiology, robotics, and modeling neuromuscular diseases.

Entities:  

Year:  2013        PMID: 24046483      PMCID: PMC3765224          DOI: 10.1063/1.4817939

Source DB:  PubMed          Journal:  Appl Phys Lett        ISSN: 0003-6951            Impact factor:   3.791


  18 in total

1.  Evaluation of the strength-size relationship in vivo using various muscle size indices.

Authors:  M M Bamman; B R Newcomer; D E Larson-Meyer; R L Weinsier; G R Hunter
Journal:  Med Sci Sports Exerc       Date:  2000-07       Impact factor: 5.411

Review 2.  Cantilever-based biosensors.

Authors:  Christiane Ziegler
Journal:  Anal Bioanal Chem       Date:  2004-07-28       Impact factor: 4.142

3.  Functional evaluation of nerve-skeletal muscle constructs engineered in vitro.

Authors:  Lisa M Larkin; Jack H Van der Meulen; Robert G Dennis; Jeffrey B Kennedy
Journal:  In Vitro Cell Dev Biol Anim       Date:  2006 Mar-Apr       Impact factor: 2.416

4.  Embryonic motoneuron-skeletal muscle co-culture in a defined system.

Authors:  M Das; J W Rumsey; C A Gregory; N Bhargava; J-F Kang; P Molnar; L Riedel; X Guo; J J Hickman
Journal:  Neuroscience       Date:  2007-03-23       Impact factor: 3.590

5.  Integration of functional myotubes with a Bio-MEMS device for non-invasive interrogation.

Authors:  Kerry Wilson; Peter Molnar; James Hickman
Journal:  Lab Chip       Date:  2007-04-20       Impact factor: 6.799

6.  Excitability and contractility of skeletal muscle engineered from primary cultures and cell lines.

Authors:  R G Dennis; P E Kosnik; M E Gilbert; J A Faulkner
Journal:  Am J Physiol Cell Physiol       Date:  2001-02       Impact factor: 4.249

7.  Relationships between muscle strength and muscle cross-sectional area in male sprinters and endurance runners.

Authors:  R J Maughan; J S Watson; J Weir
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1983

8.  Strength and cross-sectional area of human skeletal muscle.

Authors:  R J Maughan; J S Watson; J Weir
Journal:  J Physiol       Date:  1983-05       Impact factor: 5.182

9.  The role of extracellular matrix composition in structure and function of bioengineered skeletal muscle.

Authors:  Sara Hinds; Weining Bian; Robert G Dennis; Nenad Bursac
Journal:  Biomaterials       Date:  2011-02-13       Impact factor: 12.479

10.  Developing a novel serum-free cell culture model of skeletal muscle differentiation by systematically studying the role of different growth factors in myotube formation.

Authors:  Mainak Das; John W Rumsey; Neelima Bhargava; Cassie Gregory; Lisa Reidel; Jung Fong Kang; James J Hickman
Journal:  In Vitro Cell Dev Biol Anim       Date:  2009-05-09       Impact factor: 2.416

View more
  17 in total

1.  Mechanistic investigation of adult myotube response to exercise and drug treatment in vitro using a multiplexed functional assay system.

Authors:  C W McAleer; A S T Smith; S Najjar; K Pirozzi; C J Long; J J Hickman
Journal:  J Appl Physiol (1985)       Date:  2014-10-09

2.  Investigation of the effect of hepatic metabolism on off-target cardiotoxicity in a multi-organ human-on-a-chip system.

Authors:  Carlota Oleaga; Anne Riu; Sandra Rothemund; Andrea Lavado; Christopher W McAleer; Christopher J Long; Keisha Persaud; Narasimhan Sriram Narasimhan; My Tran; Jeffry Roles; Carlos A Carmona-Moran; Trevor Sasserath; Daniel H Elbrecht; Lee Kumanchik; L Richard Bridges; Candace Martin; Mark T Schnepper; Gail Ekman; Max Jackson; Ying I Wang; Reine Note; Jessica Langer; Silvia Teissier; James J Hickman
Journal:  Biomaterials       Date:  2018-08-04       Impact factor: 12.479

Review 3.  Multiorgan Microphysiological Systems for Drug Development: Strategies, Advances, and Challenges.

Authors:  Ying I Wang; Carlos Carmona; James J Hickman; Michael L Shuler
Journal:  Adv Healthc Mater       Date:  2017-12-04       Impact factor: 9.933

Review 4.  Self-contained, low-cost Body-on-a-Chip systems for drug development.

Authors:  Ying I Wang; Carlota Oleaga; Christopher J Long; Mandy B Esch; Christopher W McAleer; Paula G Miller; James J Hickman; Michael L Shuler
Journal:  Exp Biol Med (Maywood)       Date:  2017-02-17

5.  A multiplexed chip-based assay system for investigating the functional development of human skeletal myotubes in vitro.

Authors:  A S T Smith; C J Long; K Pirozzi; S Najjar; C McAleer; H H Vandenburgh; J J Hickman
Journal:  J Biotechnol       Date:  2014-06-05       Impact factor: 3.307

Review 6.  Engineered skeletal muscles for disease modeling and drug discovery.

Authors:  Jason Wang; Alastair Khodabukus; Lingjun Rao; Keith Vandusen; Nadia Abutaleb; Nenad Bursac
Journal:  Biomaterials       Date:  2019-08-08       Impact factor: 12.479

7.  Piezoelectric BioMEMS Cantilever for Measurement of Muscle Contraction and for Actuation of Mechanosensitive Cells.

Authors:  Elizabeth A Coln; Alisha Colon; Christopher J Long; Narasimhan Narasimhan Sriram; Mandy Esch; Jean-Matthieu Prot; Daniel H Elbrecht; Ying Wang; Max Jackson; Michael L Shuler; James J Hickman
Journal:  MRS Commun       Date:  2019-09-20       Impact factor: 2.566

8.  Utilization of microscale silicon cantilevers to assess cellular contractile function in vitro.

Authors:  Alec S T Smith; Christopher J Long; Christopher McAleer; Nathaniel Bobbitt; Balaji Srinivasan; James J Hickman
Journal:  J Vis Exp       Date:  2014-10-03       Impact factor: 1.355

Review 9.  Physiology and metabolism of tissue-engineered skeletal muscle.

Authors:  Cindy S Cheng; Brittany N J Davis; Lauran Madden; Nenad Bursac; George A Truskey
Journal:  Exp Biol Med (Maywood)       Date:  2014-06-09

10.  Microphysiological heart-liver body-on-a-chip system with a skin mimic for evaluating topical drug delivery.

Authors:  Camilly P Pires de Mello; Carlos Carmona-Moran; Christopher W McAleer; Julian Perez; Elizabeth A Coln; Christopher J Long; Carlota Oleaga; Anne Riu; Reine Note; Silvia Teissier; Jessica Langer; James J Hickman
Journal:  Lab Chip       Date:  2020-01-23       Impact factor: 6.799

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.