Literature DB >> 24038576

Task force report: scales for screening and evaluating tremor: critique and recommendations.

Rodger Elble1, Peter Bain, Maria João Forjaz, Dietrich Haubenberger, Claudia Testa, Christopher G Goetz, Albert F G Leentjens, Pablo Martinez-Martin, Anne Pavy-Le Traon, Bart Post, Cristina Sampaio, Glenn T Stebbins, Daniel Weintraub, Anette Schrag.   

Abstract

The Movement Disorder Society established a task force to review rating scales for the assessment of tremor. Screening instruments used in identifying patients with tremor were also reviewed. Seven tremor severity scales, six activities of daily living (ADL)/disability scales, four quality-of-life scales, and five screening instruments were identified by searching PubMed.gov. The availability, use, acceptability, reliability, validity, and sensitivity to change were reviewed for each scale; and each scale was classified as recommended, suggested or listed based on whether 3, 2, or 1 of the following criteria were met: (1) used in the assessment of tremor (yes/no), (2) used in published studies by people other than the developers (yes/no), and (3) successful clinimetric testing (yes/no). Five tremor severity scales (the Fahn-Tolosa-Marin Tremor Rating Scale, the Bain and Findley Clinical Tremor Rating Scale, the Bain and Findley Spirography Scale, the Washington Heights-Inwood Genetic Study of Essential Tremor Rating Scale, and the Tremor Research Group Essential Tremor Rating Assessment Scale), one ADL/disability scale (the Bain and Findley Tremor ADL Scale), one quality-of-life scale (the Quality of Life in Essential Tremor Questionnaire), and one screening instrument (the Washington Heights-Inwood Genetic Study of Essential Tremor Rating Scale, version 1) are recommended using these criteria. However, all scales need a more comprehensive analysis of sensitivity to change in order to judge their utility in clinical trials and individual patient assessments. The task force recommends that further work with existing recommended scales be performed as opposed to the development of new tremor scales.
© 2013 International Parkinson and Movement Disorder Society.

Entities:  

Keywords:  rating scales; reliability; sensitivity; tremor; validity

Mesh:

Year:  2013        PMID: 24038576     DOI: 10.1002/mds.25648

Source DB:  PubMed          Journal:  Mov Disord        ISSN: 0885-3185            Impact factor:   10.338


  38 in total

1.  TREMOR12: An Open-Source Mobile App for Tremor Quantification.

Authors:  Pieter L Kubben; Mark L Kuijf; Linda P C M Ackermans; Albert F G Leentjens; Yasin Temel
Journal:  Stereotact Funct Neurosurg       Date:  2016-07-09       Impact factor: 1.875

Review 2.  Transducer-based evaluation of tremor.

Authors:  Dietrich Haubenberger; Giovanni Abbruzzese; Peter G Bain; Nin Bajaj; Julián Benito-León; Kailash P Bhatia; Günther Deuschl; Maria João Forjaz; Mark Hallett; Elan D Louis; Kelly E Lyons; Tiago A Mestre; Jan Raethjen; Maria Stamelou; Eng-King Tan; Claudia M Testa; Rodger J Elble
Journal:  Mov Disord       Date:  2016-06-06       Impact factor: 10.338

Review 3.  Knowledge gaps and research recommendations for essential tremor.

Authors:  Franziska Hopfner; Dietrich Haubenberger; Wendy R Galpern; Katrina Gwinn; Ashlee Van't Veer; Samantha White; Kailash Bhatia; Charles H Adler; David Eidelberg; William Ondo; Glenn T Stebbins; Caroline M Tanner; Rick C Helmich; Fred A Lenz; Roy V Sillitoe; David Vaillancourt; Jerrold L Vitek; Elan D Louis; Holly A Shill; Matthew P Frosch; Tatiana Foroud; Gregor Kuhlenbäumer; Andrew Singleton; Claudia M Testa; Mark Hallett; Rodger Elble; Günther Deuschl
Journal:  Parkinsonism Relat Disord       Date:  2016-10-04       Impact factor: 4.891

4.  Differences in postural tremor dynamics with age and neurological disease.

Authors:  Steven Morrison; Karl M Newell; Justin J Kavanagh
Journal:  Exp Brain Res       Date:  2017-03-09       Impact factor: 1.972

5.  Vim stereotactic radiosurgical thalamotomy for drug-resistant idiopathic Holmes tremor: a case report.

Authors:  Manjul Tripathi; Sahil Mehta; Raghav Singla; Chirag K Ahuja; Naresh Tandalya; Constantin Tuleasca; Aman Batish; Sandeep Mohindra; Abhinav Agrahari; Rupinder Kaur
Journal:  Acta Neurochir (Wien)       Date:  2020-07-17       Impact factor: 2.216

Review 6.  Measurement Instruments to Assess Functional Mobility in Parkinson's Disease: A Systematic Review.

Authors:  Raquel Bouça-Machado; Gonçalo S Duarte; Maria Patriarca; Ana Castro Caldas; Joana Alarcão; Ricardo M Fernandes; Tiago A Mestre; Ricardo Matias; Joaquim J Ferreira
Journal:  Mov Disord Clin Pract       Date:  2019-12-11

Review 7.  Magnetic Resonance-Guided Focused Ultrasound Neurosurgery for Essential Tremor: A Health Technology Assessment.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2018-05-03

8.  Magnetic resonance-guided focused ultrasound treatment for essential tremor shows sustained efficacy: a meta-analysis.

Authors:  William K Miller; Kathryn N Becker; Andrew J Caras; Tarek R Mansour; Malik T Mays; Mehmood Rashid; Jason Schwalb
Journal:  Neurosurg Rev       Date:  2021-05-12       Impact factor: 3.042

9.  Comparison of the Fahn-Tolosa-Marin Clinical Rating Scale and the Essential Tremor Rating Assessment Scale.

Authors:  William Ondo; Vera Hashem; Peter A LeWitt; Rajesh Pahwa; Ludy Shih; Daniel Tarsy; Theresa Zesiewicz; Rodger Elble
Journal:  Mov Disord Clin Pract       Date:  2017-11-23

10.  Deep Brain Stimulation for Multiple Sclerosis Tremor: A Meta-Analysis.

Authors:  Nicholas J Brandmeir; Ann Murray; Cletus Cheyuo; Christopher Ferari; Ali R Rezai
Journal:  Neuromodulation       Date:  2019-11-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.