| Literature DB >> 24037072 |
Emilia Adriane Silva1, Flávia Zardo Trindade, Hélcio Nagib José Feres Reskalla, José Renato Cavalcanti de Queiroz.
Abstract
OBJECTIVE: This study aimed to evaluate the effects of heat treatment on the tribochemical silica coating and silane surface conditioning and the bond strength of rebonded alumina monocrystalline brackets.Entities:
Mesh:
Substances:
Year: 2013 PMID: 24037072 PMCID: PMC3881885 DOI: 10.1590/1678-775720130012
Source DB: PubMed Journal: J Appl Oral Sci ISSN: 1678-7757 Impact factor: 2.698
Figure 1Scanning electron microscopy images in SE mode using 2,000x magnification showing: a)base of new bracket with zirconia pearls (Z) as a mechanical retention mechanism spread on the alumina surface; b) base of bracket following tribochemical silica coating. Note the absence of zirconia pearls. Instead, the alumina surface presented cracks on the spots where the zirconia pearls were sputtered (C)
The p value by 2-way ANOVA determined for shear bond strength (SBS) and roughness parameters (Ra, RSm and Rc) for different factors (surface treatment, ST; Thermocycling, TC) (*p<0.05)
| p for SBS | 0.0* | 0.6974 | 0.0136* |
| p for Ra | 0.4776 | 0.0037* | 0.3676 |
| p for RSm | 0.3373 | 0.4116 | 0.6792 |
| p for Rc | 0.658 | 0.0018* | 0.2013 |
Mean and standard deviation for shear bond strength (SBS), roughness parameters (Ra, RSm and Rc) and failure modes of the groups according to the adhesive remnant index (ARI) on the enamel surface: ARI 3, 100% of composite; ARI 2, >50% of composite; ARI 1, <50% of composite; ARI 0, 0% of composite. *Same superscript letters indicate no statistically significant differences for SBS. (Tukey test, α=0.05)
| ARI 3 | ARI 2 | ARI 1 | ARI 0 | Ra | Rc | RSm | ||
| Gc | 27.18ª±2.9 | - | 1 | 9 | 0 | 0.43±0.1 | 1.23±0.4 | 5.5±0.8 |
| Gt | 12.0bc±6.1 | 1 | 3 | 3 | 3 | 0.36±0.1 | 1.04±0.2 | 5.09±0.7 |
| Gh | 19.16ab±8.2 | - | - | 8 | 2 | 0.37±0.1 | 1.03±0.2 | 5.58±0.5 |
| Gc-TC | 24.33ª±5.1 | - | - | 9 | 1 | 0.31±0.1 | 0.82±0.1 | 5.27±0.9 |
| Gt-TC | 8.45c±6.7 | 3 | 1 | 6 | - | 0.32±0.1 | 0.91±0.2 | 5.13±0.4 |
| Gh-TC | 27.59ª±6.4 | - | - | 8 | 2 | 0.30±0.1 | 0.87±0.1 | 5.21±0.5 |
Figure 2Scanning electron microscopy images in SE mode at 2,000x magnification showing brackets with mixed failure for Gh-TC with >50% of resin composite on the bracket (adhesive remnant index - ARI=1) associated with enamel fracture. The bracket (B), composite (C), enamel (E) and spot of roughness evaluated (R) are showed on the micrograph