Literature DB >> 24036178

Optoelectronic plethysmography: intra-rater and inter-rater reliability in healthy subjects.

Danielle S R Vieira1, Mariana Hoffman, Danielle A G Pereira, Raquel R Britto, Verônica F Parreira.   

Abstract

Optoelectronic plethysmography (OEP) has been used to measure changes in chest wall volume and its compartments. However, literature lacks research on its reliability. The purpose of this study was to evaluate the intra-rater and inter-rater reliability of OEP. Thirty-two healthy subjects were evaluated at rest and during submaximal exercise on a cycle ergometer. The following variables were assessed: chest wall volume (VCW); percentage contribution of the pulmonary rib cage (V(rcp)%), abdominal rib cage (V(rca)%), rib cage (V(rc)%) and abdomen (Vab%); chest wall end-expiratory volume (Vee(cw)); chest wall end-inspiratory volume (Vei(cw)); ratio of inspiratory time to total time of the respiratory cycle (Ti/T(tot)); respiratory rate (f) and mean inspiratory flow (V(cw)/Ti). Intraclass correlation coefficient (ICC) and coefficient of variation of Method Error (CV(ME)) were used to evaluate reliability. Results showed ICC values higher than 0.75 and CV(ME) values less than 10% for most variables at rest and during exercise indicating that OEP is a reliable instrument to assess chest wall volumes at rest and during exercise in healthy subjects.
Copyright © 2013 Elsevier B.V. All rights reserved.

Keywords:  Chest wall volumes; Exercise; Optoelectronic plethysmography; Reliability

Mesh:

Year:  2013        PMID: 24036178     DOI: 10.1016/j.resp.2013.08.023

Source DB:  PubMed          Journal:  Respir Physiol Neurobiol        ISSN: 1569-9048            Impact factor:   1.931


  6 in total

1.  Influence of posture, sex, and age on breathing pattern and chest wall motion in healthy subjects.

Authors:  Liliane Patrícia De Souza Mendes; Danielle Soares Rocha Vieira; Leticia Silva Gabriel; Giane Amorim Ribeiro-Samora; Armèle Dornelas De Andrade; Daniella Cunha Brandão; Maria Clara Goes; Guilherme Augusto Freitas Fregonezi; Raquel Rodrigues Britto; Verônica Franco Parreira
Journal:  Braz J Phys Ther       Date:  2019-03-01       Impact factor: 3.377

2.  A novel acquisition platform for long-term breathing frequency monitoring based on inertial measurement units.

Authors:  Ambra Cesareo; Emilia Biffi; David Cuesta-Frau; Maria G D'Angelo; Andrea Aliverti
Journal:  Med Biol Eng Comput       Date:  2020-01-30       Impact factor: 2.602

3.  Breathing exercises: influence on breathing patterns and thoracoabdominal motion in healthy subjects.

Authors:  Danielle S R Vieira; Liliane P S Mendes; Nathália S Elmiro; Marcelo Velloso; Raquel R Britto; Verônica F Parreira
Journal:  Braz J Phys Ther       Date:  2014 Nov-Dec       Impact factor: 3.377

4.  Spontaneous Breathing Pattern as Respiratory Functional Outcome in Children with Spinal Muscular Atrophy (SMA).

Authors:  A LoMauro; A Aliverti; C Mastella; M T Arnoldi; P Banfi; G Baranello
Journal:  PLoS One       Date:  2016-11-07       Impact factor: 3.240

5.  Effects of non-invasive ventilation and posture on chest wall volumes and motion in patients with amyotrophic lateral sclerosis: a case series.

Authors:  Cristiana M Magalhães; Guilherme A Fregonezi; Mauro Vidigal-Lopes; Bruna S P P Vieira; Danielle S R Vieira; Verônica F Parreira
Journal:  Braz J Phys Ther       Date:  2016-06-16       Impact factor: 3.377

6.  Effects of positive expiratory pressure on chest wall volumes in subjects with stroke compared to healthy controls: a case-control study.

Authors:  Elis E A Cabral; Vanessa R Resqueti; Illia N D F Lima; Lucien P Gualdi; Andrea Aliverti; Guilherme A F Fregonezi
Journal:  Braz J Phys Ther       Date:  2017-07-08       Impact factor: 3.377

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.