Literature DB >> 24034699

Visualization and hypervascularization of the haemorrhoidal plexus in vivo using power Doppler imaging transanal ultrasonography and three-dimensional power Doppler angiography.

H Miyamoto1, M Asanoma, H Miyamoto1, C Takasu, K Masamune, M Shimada.   

Abstract

AIM: The purpose of this study was to demonstrate the distribution of haemorrhoidal arteries and the relationship between vascularity and growth of haemorrhoids.
METHOD: One-hundred and three patients with haemorrhoids were studied. Using power Doppler imaging (PDI) transanal ultrasound and three-dimensional power Doppler angiography (3D-PDA), the course of the arteries supplying the haemorrhoids was identified. Measurement of the PDI area was made using the cursor to outline the power Doppler signal of the haemorrhoid, approximately 1 cm above the dentate line.
RESULTS: The haemorrhoidal arteries were seen as branches of the superior rectal artery and were detected in 75.7, 71.8, 68.0 and 62.1% of the 11, 7, 3 and 1 o'clock positions in the lithotomy position. The median number of haemorrhoidal arteries significantly increased from three to six with progression of the Goligher classification from Grade 1 to Grade 4 (P < 0.0001). The PDI areas in Grades 1, 2, 3 and 4 were 0.04 ± 0.03, 0.18 ± 0.07, 0.38 ± 0.18 and 0.96 ± 0.32 cm(2) (P < 0.05).
CONCLUSION: The distribution of haemorrhoidal arteries varies widely in both number and position. Using PDI transanal ultrasonography and 3D-PDA it was possible to visualize the haemorrhoid plexus and the course of the haemorrhoidal artery in vivo. Colorectal Disease
© 2013 The Association of Coloproctology of Great Britain and Ireland.

Entities:  

Keywords:  Haemorrhoidal artery; internal haemorrhoid; power Doppler imaging; three-dimensional power Doppler angiography

Mesh:

Year:  2013        PMID: 24034699     DOI: 10.1111/codi.12406

Source DB:  PubMed          Journal:  Colorectal Dis        ISSN: 1462-8910            Impact factor:   3.788


  4 in total

Review 1.  Emborrhoid: Rectal Artery Embolization for Hemorrhoid Disease.

Authors:  Julien Panneau; Diane Mege; Mathieu Di Biseglie; Julie Duclos; Paul Habert; Vincent Vidal; Farouk Tradi
Journal:  Semin Intervent Radiol       Date:  2022-06-30       Impact factor: 1.780

2.  CT colonography has low sensitivity but high specificity in the detection of internal hemorrhoids.

Authors:  Lukas Lambert; Jiri Jahoda; Gabriela Grusova; Pavel Hrabak; Ales Novotny; Andrea Burgetova
Journal:  Diagn Interv Radiol       Date:  2020-03       Impact factor: 2.630

3.  Sonographic appearance of anal cushions of hemorrhoids.

Authors:  Adilijiang Aimaiti; Ma Mu Ti Jiang A Ba Bai Ke Re; Irshat Ibrahim; Hui Chen; Maimaitituerxun Tuerdi
Journal:  World J Gastroenterol       Date:  2017-05-28       Impact factor: 5.742

4.  Comparison of different embolic particles for superior rectal arterial embolization of chronic hemorrhoidal bleeding: gelfoam versus microparticle.

Authors:  Xuemin Wang; Yuguo Sheng; Zhu Wang; Wenming Wang; Fengfei Xia; Mengpeng Zhao; Xinqiang Han
Journal:  BMC Gastroenterol       Date:  2021-12-14       Impact factor: 3.067

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.