Literature DB >> 24034509

A comparison of modular tapered versus modular cylindrical stems for complex femoral revisions.

.   

Abstract

The effect of distal geometry in modular stems in revision THA remains unclear. The purpose of this study is to compare femoral revisions with modular tapered versus modular cylindrical stems in high-grade defects. A multicenter review of 105 femoral revisions with Paprosky III/IV defects using modular titanium stems (61 tapered; 44 cylindrical) was performed with an average follow-up of 5 years. Demographic data was comparable between groups. The tapered group had more IIIB and IV defects (51% vs. 20%; P < .01). The failure rate for component osseointegration was 1.6% in the tapered group and 15.9% in the cylindrical group (P = <.01). The rate of femoral component re-revision for any reason was 4.9% in the tapered group and 22.7% in the cylindrical group (P = .013). Modular tapered stems were associated with lower rates of stem failure and improved bone ongrowth compared to cylindrical stems despite being used in femurs with greater defects.
© 2013 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  cylindrical modular stems; femoral revisions; hip replacement complications; modular femoral components; revision total hip arthroplasty; tapered modular stems

Mesh:

Year:  2013        PMID: 24034509     DOI: 10.1016/j.arth.2013.04.052

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  8 in total

1.  CORR Insights®: modular tapered implants for severe femoral bone loss in THA: reliable osseointegration but frequent complications.

Authors:  Curtis W Hartman
Journal:  Clin Orthop Relat Res       Date:  2014-09-09       Impact factor: 4.176

2.  Modular tapered implants for severe femoral bone loss in THA: reliable osseointegration but frequent complications.

Authors:  Nicholas M Brown; Matthew Tetreault; Cara A Cipriano; Craig J Della Valle; Wayne Paprosky; Scott Sporer
Journal:  Clin Orthop Relat Res       Date:  2015-02       Impact factor: 4.176

3.  Distal fixation stems for revision of total hip replacement.

Authors:  Fernando Lopreite; Leonel Perez Alamino; Harold Simesen de Bielke; German Garabano; Hernán Del Sel
Journal:  J Orthop       Date:  2021-02-21

4.  Tapered modular fluted titanium stems for femoral fixation in revision total knee arthroplasty.

Authors:  Jeffrey B Stambough; J Bohannon Mason; Aldo M Riesgo; Thomas K Fehring
Journal:  Arthroplast Today       Date:  2017-04-21

5.  Comparison of cylindrical and tapered stem designs for femoral revision hip arthroplasty.

Authors:  Yu Zhang; Ye Zhang; Jian-Ning Sun; Zi-Jian Hua; Xiang-Yang Chen; Shuo Feng
Journal:  BMC Musculoskelet Disord       Date:  2020-06-29       Impact factor: 2.362

6.  Medium Term Radiographic and Clinical Outcomes Using a Modular Tapered Hip Revision Implant.

Authors:  Gihan Jayasinghe; Chris Buckle; Lucy Clare Maling; Christopher To; Chukwudubem Anibueze; Parthiban Vinayakam; Richard Slack
Journal:  Arthroplast Today       Date:  2021-04-05

7.  Technical Note for Transfemoral Implantation of Tapered Revision Stems. The Advantage to Stay Short.

Authors:  Bernd Fink
Journal:  Arthroplast Today       Date:  2021-04-24

8.  A Contemporary Classification System of Femoral Bone Loss in Revision Total Hip Arthroplasty.

Authors:  Bryeson Rodgers; Gabrielle Wernick; Gabrielle Roman; Christopher P Beauchamp; Mark J Spangehl; Adam J Schwartz
Journal:  Arthroplast Today       Date:  2021-06-18
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.