Literature DB >> 2403189

Repeatability of the KT-1000 arthrometer in a normal population.

R R Wroble1, L A Van Ginkel, E S Grood, F R Noyes, B L Shaffer.   

Abstract

Despite its popularity, the MEDmetric KT-1000 arthrometer's reliability remains inadequately documented. We conducted this study to determine the magnitude of trial-to-trial (within installation), installation-to-installation (within day), and day-to-day (between day) variability of anterior/posterior translation measurements in normal knees. We selected six normal subjects, three males and three females, and tested each on 6 consecutive days with three separate installations per day. We recorded the total anterior/posterior translation at +/- 89 and +/- 134 N force at 25 degrees of flexion during three consecutive trials in a single installation. Analysis of variance showed that no significant difference existed between trials (within installation) or between installations (within day) for all parameters. However, we did find a significant difference between days for individual right and left knee translation measurements at 89 and 134 N force. More importantly, no significant difference existed between days for right to left differences at both force levels. The magnitude of the expected measurement variability was expressed by computing 90% confidence limits for total anterior/posterior translation at +/- 89 N force. These were +/- 1.5 mm for the right knees, +/- 1.4 mm for the left knees, and +/- 1.6 mm for the right-left differences. Fischer's protected least significant difference post hoc test revealed that for all parameters, the 1st day measurements were significantly less than those on following days, suggesting that patient and examiner adjust to the testing procedure. We conclude that the standard KT-1000 evaluation should report paired differences rather than individual knee measurements. Additionally, initial evaluation should be supplemented by follow-up examinations for verifying translation values.

Entities:  

Mesh:

Year:  1990        PMID: 2403189     DOI: 10.1177/036354659001800411

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  38 in total

1.  Association of Menstrual-Cycle Hormone Changes with Anterior Cruciate Ligament Laxity Measurements.

Authors:  Bonnie L. Van Lunen; John Roberts; J David Branch; Elizabeth A. Dowling
Journal:  J Athl Train       Date:  2003-12       Impact factor: 2.860

2.  Influences of Clinician Technique on Performance and Interpretation of the Lachman Test.

Authors:  Wendy L. Hurley; D Thompson McGuire
Journal:  J Athl Train       Date:  2003-03       Impact factor: 2.860

3.  The effects of anterior cruciate ligament reconstruction on tibial rotation during pivoting after descending stairs.

Authors:  S Ristanis; G Giakas; C D Papageorgiou; T Moraiti; N Stergiou; A D Georgoulis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2003-10-03       Impact factor: 4.342

4.  Objective evaluation of anterior knee laxity; comparison of the KT-1000 and GNRB® arthrometers.

Authors:  Michel Collette; Julie Courville; Marc Forton; Bertrand Gagnière
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-01-10       Impact factor: 4.342

Review 5.  The effects of the menstrual cycle on anterior knee laxity: a systematic review.

Authors:  Bohdanna T Zazulak; Mark Paterno; Gregory D Myer; William A Romani; Timothy E Hewett
Journal:  Sports Med       Date:  2006       Impact factor: 11.136

6.  Anterior tibial translation in collegiate athletes with normal anterior cruciate ligament integrity.

Authors:  J M Rosene; T D Fogarty
Journal:  J Athl Train       Date:  1999-04       Impact factor: 2.860

7.  Instrumented measurements of knee laxity: KT-1000 versus navigation.

Authors:  Edoardo Monaco; Luca Labianca; Barbara Maestri; Angelo De Carli; Fabio Conteduca; Andrea Ferretti
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-02-24       Impact factor: 4.342

8.  In vivo laxity of stable versus anterior cruciate ligament-injured knees using a navigation system: a comparative study.

Authors:  Eun Kyoo Song; Jong Keun Seon; Sang Jin Park; Chang Ich Hur; Dam Seon Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-04-10       Impact factor: 4.342

9.  Anterior cruciate ligament reconstruction in patients over 40 years using hamstring autograft.

Authors:  R M Khan; V Prasad; R Gangone; J C Kinmont
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-08-12       Impact factor: 4.342

10.  Performance-based functional outcome for children 12 years or younger following anterior cruciate ligament injury: a two to nine-year follow-up study.

Authors:  Håvard Moksnes; Lars Engebretsen; May Arna Risberg
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-12-22       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.