Literature DB >> 19238362

Instrumented measurements of knee laxity: KT-1000 versus navigation.

Edoardo Monaco1, Luca Labianca, Barbara Maestri, Angelo De Carli, Fabio Conteduca, Andrea Ferretti.   

Abstract

The KT-1000 is widely accepted as a tool for the instrumented measurement of the antero-posterior (AP) tibial translation. The aim of this study is to compare the data obtained with the KT-1000 in ACL deficient knees with the data obtained using a navigation system during "in vivo" ACL reconstruction procedures and to validate the accuracy of the KT-1000. An ACL reconstruction was performed using computer aided surgical navigation (Orthopilot, B-Braun, Aesculap, Tuttlingen, Germany) in 30 patients. AP laxity measurements were obtained for all patients using KT-1000 arthrometer (in a conscious state and under general anaesthesia) and during surgery using the navigation system, always at 30 degrees of knee flexion. The mean AP translation was 14 +/- 4 and 15.6 +/- 3.8 mm using the KT-1000 in conscious and under general anaesthesia, respectively (P = 0.02) and 16.1 +/- 3.7 mm using navigation. Measurements obtained with the KT-1000 under general anaesthesia were no different from those obtained "in vivo" with the navigation system (P = 0.37). In conclusion this study validates the accuracy of the KT-1000 to exactly calculate AP translation of the tibia, in comparison with the more accurate measurements obtained using a navigation system.

Entities:  

Mesh:

Year:  2009        PMID: 19238362     DOI: 10.1007/s00167-009-0724-1

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  30 in total

1.  Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique.

Authors:  H Bäthis; L Perlick; M Tingart; C Lüring; D Zurakowski; J Grifka
Journal:  J Bone Joint Surg Br       Date:  2004-07

2.  Computer-navigated ACL reconstruction with the OrthoPilot.

Authors:  Markus Degenhart
Journal:  Surg Technol Int       Date:  2004

3.  Computer assisted navigation in total knee arthroplasty: comparison with conventional methods.

Authors:  Kevin C Anderson; Knute C Buehler; David C Markel
Journal:  J Arthroplasty       Date:  2005-10       Impact factor: 4.757

4.  Reliability of navigated knee stability examination: a cadaveric evaluation.

Authors:  Andrew D Pearle; Daniel J Solomon; Tony Wanich; Alexandre Moreau-Gaudry; Carinne C Granchi; Thomas L Wickiewicz; Russell F Warren
Journal:  Am J Sports Med       Date:  2007-04-17       Impact factor: 6.202

5.  The Stryker knee arthrometer in clinical practice.

Authors:  J B King; S J Kumar
Journal:  Am J Sports Med       Date:  1989 Sep-Oct       Impact factor: 6.202

6.  An in vivo comparison of anterior tibial translation and strain in the anteromedial band of the anterior cruciate ligament.

Authors:  B C Fleming; B D Beynnon; C E Nichols; R J Johnson; M H Pope
Journal:  J Biomech       Date:  1993-01       Impact factor: 2.712

7.  Diagnosis of an ACL disruption with KT-1000 arthrometer measurements.

Authors:  C Rangger; D M Daniel; M L Stone; K Kaufman
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  1993       Impact factor: 4.342

8.  Quantitative analysis of the measuring capabilities of the KT-1000 knee ligament arthrometer.

Authors:  D L Kowalk; E M Wojtys; J Disher; P Loubert
Journal:  Am J Sports Med       Date:  1993 Sep-Oct       Impact factor: 6.202

9.  Instrumented measurement of anterior laxity of the knee.

Authors:  D M Daniel; L L Malcom; G Losse; M L Stone; R Sachs; R Burks
Journal:  J Bone Joint Surg Am       Date:  1985-06       Impact factor: 5.284

10.  Double bundle or single bundle plus extraarticular tenodesis in ACL reconstruction? A CAOS study.

Authors:  E Monaco; L Labianca; F Conteduca; A De Carli; A Ferretti
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-06-23       Impact factor: 4.342

View more
  7 in total

Review 1.  Rotatory knee laxity tests and the pivot shift as tools for ACL treatment algorithm.

Authors:  Volker Musahl; Sebastian Kopf; Stephen Rabuck; Roland Becker; Willem van der Merwe; Stefano Zaffagnini; Freddie H Fu; Jon Karlsson
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-12-30       Impact factor: 4.342

2.  Applications of computer navigation in sports medicine knee surgery: an evidence-based review.

Authors:  Simon W Young; Marc R Safran; Mark Clatworthy
Journal:  Curr Rev Musculoskelet Med       Date:  2013-06

3.  Smartphone versus knee ligament arthrometer when size does not matter.

Authors:  Andrea Ferretti; Ferretti Andrea; Luigi Valeo; Valeo Luigi; Daniele Mazza; Mazza Daniele; Luca Muliere; Muliere Luca; Paolo Iorio; Iorio Paolo; Giovanni Giovannetti; Giovannetti Giovanni; Fabio Conteduca; Conteduca Fabio; Raffaele Iorio; Iorio Raffaele
Journal:  Int Orthop       Date:  2014-07-09       Impact factor: 3.075

4.  Experimental loss of menisci, cartilage and subchondral bone gradually increases anteroposterior knee laxity.

Authors:  Karl Wieser; Michael Betz; Mazda Farshad; Magdalena Vich; Sandro F Fucentese; Dominik C Meyer
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-30       Impact factor: 4.342

5.  A new diagnostic approach using regional analysis of anterior knee laxity in patients with anterior cruciate ligament deficiency.

Authors:  Hsiu-Chen Lin; Chia-Ming Chang; Horng-Chaung Hsu; Weng-Hang Lai; Tung-Wu Lu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-01-21       Impact factor: 4.342

Review 6.  Current use of navigation system in ACL surgery: a historical review.

Authors:  S Zaffagnini; F Urrizola; C Signorelli; A Grassi; T Roberti Di Sarsina; G A Lucidi; G M Marcheggiani Muccioli; T Bonanzinga; M Marcacci
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-10-15       Impact factor: 4.342

7.  Differences in Knee Kinematics Between Awake and Anesthetized Patients During the Lachman and Pivot-Shift Tests for Anterior Cruciate Ligament Deficiency.

Authors:  Takehiko Matsushita; Shinya Oka; Kouki Nagamune; Tomoyuki Matsumoto; Yuichiro Nishizawa; Yuichi Hoshino; Seiji Kubo; Masahiro Kurosaka; Ryosuke Kuroda
Journal:  Orthop J Sports Med       Date:  2013-05-02
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.