Literature DB >> 24027619

Graphics Processing Unit (GPU) implementation of image processing algorithms to improve system performance of the Control, Acquisition, Processing, and Image Display System (CAPIDS) of the Micro-Angiographic Fluoroscope (MAF).

S N Swetadri Vasan1, Ciprian N Ionita, A H Titus, A N Cartwright, D R Bednarek, S Rudin.   

Abstract

We present the image processing upgrades implemented on a Graphics Processing Unit (GPU) in the Control, Acquisition, Processing, and Image Display System (CAPIDS) for the custom Micro-Angiographic Fluoroscope (MAF) detector. Most of the image processing currently implemented in the CAPIDS system is pixel independent; that is, the operation on each pixel is the same and the operation on one does not depend upon the result from the operation on the other, allowing the entire image to be processed in parallel. GPU hardware was developed for this kind of massive parallel processing implementation. Thus for an algorithm which has a high amount of parallelism, a GPU implementation is much faster than a CPU implementation. The image processing algorithm upgrades implemented on the CAPIDS system include flat field correction, temporal filtering, image subtraction, roadmap mask generation and display window and leveling. A comparison between the previous and the upgraded version of CAPIDS has been presented, to demonstrate how the improvement is achieved. By performing the image processing on a GPU, significant improvements (with respect to timing or frame rate) have been achieved, including stable operation of the system at 30 fps during a fluoroscopy run, a DSA run, a roadmap procedure and automatic image windowing and leveling during each frame.

Entities:  

Year:  2012        PMID: 24027619      PMCID: PMC3767001          DOI: 10.1117/12.911272

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  5 in total

1.  LabVIEW Graphical User Interface for a New High Sensitivity, High Resolution Micro-Angio-Fluoroscopic and ROI-CBCT System.

Authors:  C Keleshis; Cn Ionita; G Yadava; V Patel; Dr Bednarek; Kr Hoffmann; A Verevkin; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008

2.  A theoretical and experimental evaluation of the microangiographic fluoroscope: A high-resolution region-of-interest x-ray imager.

Authors:  Amit Jain; D R Bednarek; Ciprian Ionita; S Rudin
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

3.  Use of the microangiographic fluoroscope for coiling of intracranial aneurysms.

Authors:  Mandy J Binning; David Orion; Parham Yashar; Sharon Webb; Ciprian N Ionita; Amit Jain; Stephen Rudin; L Nelson Hopkins; Adnan H Siddiqui; Elad I Levy
Journal:  Neurosurgery       Date:  2011-11       Impact factor: 4.654

4.  Progress in the Development of a new Angiography Suite including the High Resolution Micro-Angiographic Fluoroscope (MAF), a Control, Acquisition, Processing, and Image Display System (CAPIDS), and a New Detector Changer Integrated into a Commercial C-Arm Angiography Unit to Enable Clinical Use.

Authors:  Weiyuan Wang; Ciprian N Ionita; Christos Keleshis; Andrew Kuhls-Gilcrist; Amit Jain; Daniel Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2010-03-23

5.  Spatially different, real-time temporal filtering and dose reduction for dynamic image guidance during neurovascular interventions.

Authors:  S N Swetadri Vasan; P Sharma; C N Ionita; A H Titus; A N Cartwright; D R Bednarek; S Rudin
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2011
  5 in total
  3 in total

1.  A Combination of Spatial and Recursive Temporal Filtering for Noise Reduction when Using Region of Interest (ROI) Fluoroscopy for Patient Dose Reduction in Image Guided Vascular Interventions with Significant Anatomical Motion.

Authors:  S V Setlur Nagesh; P Khobragade; C Ionita; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-03-18

2.  Workflow for the use of a high-resolution image detector in endovascular interventional procedures.

Authors:  R Rana; B Loughran; S N Swetadri Vasan; L Pope; C N Ionita; A Siddiqui; N Lin; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-03-19

3.  Detector system comparison using relative CNR for specific imaging tasks related to neuro-endovascular image-guided interventions (neuro-EIGIs).

Authors:  Brendan Loughran; S N Swetadri Vasan; Vivek Singh; Ciprian N Ionita; Amit Jain; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-03-19
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.