Literature DB >> 24026542

Feasibility of closed-loop insulin delivery in type 2 diabetes: a randomized controlled study.

Kavita Kumareswaran1, Hood Thabit, Lalantha Leelarathna, Karen Caldwell, Daniela Elleri, Janet M Allen, Marianna Nodale, Malgorzata E Wilinska, Mark L Evans, Roman Hovorka.   

Abstract

OBJECTIVE: Closed-loop insulin delivery offers a promising treatment option, but to date, it has only been evaluated in type 1 diabetes. Our aim was to evaluate the feasibility of fully closed-loop subcutaneous insulin delivery in insulin-naïve patients with type 2 diabetes. RESEARCH DESIGN AND METHODS: Twelve subjects (seven males, age 57.2 years, BMI 30.5 kg/m2) with noninsulin-treated type 2 diabetes (HbA1c 8.4% [68 mmol/mol], diabetes duration 7.6 years) underwent two 24-h visits (closed-loop and control) in a randomized crossover design. During closed-loop visits, the subjects' routine diabetes therapy was replaced with model predictive control algorithm-driven subcutaneous insulin pump delivery based on real-time continuous glucose monitoring. Meals were unannounced, and no additional insulin was administered for carbohydrates consumed. During control visits, the usual diabetes regimen was continued (metformin 92%, sulfonylureas 58%, dipeptidyl peptidase-4 inhibitors 33%). On both visits, subjects consumed matched 50- to 80-g carbohydrate meals and optional 15-g carbohydrate snacks and remained largely sedentary. Plasma glucose measurements evaluated closed-loop performance.
RESULTS: Compared with conventional therapy, 24 h of closed-loop insulin delivery increased overall the median time in target plasma glucose (3.9-8.0 mmol/L) from 24 to 40% (P = 0.016), despite sensor under-reading by a median of 1.2 mmol/L. The benefit of the closed-loop system was more prominent overnight, with greater time in target glucose (median 78 vs. 35%; P = 0.041) and less time in hyperglycemia (22 vs. 65%; P = 0.041). There was no hypoglycemia during either intervention.
CONCLUSIONS: A closed-loop system without meal announcement and using subcutaneous insulin delivery in insulin-naïve patients with type 2 diabetes appears feasible and safe. Improvement in postprandial glucose control may require further optimization of system performance.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24026542     DOI: 10.2337/dc13-1030

Source DB:  PubMed          Journal:  Diabetes Care        ISSN: 0149-5992            Impact factor:   19.112


  15 in total

Review 1.  Artificial Pancreas Project at Cambridge 2013.

Authors:  R Hovorka
Journal:  Diabet Med       Date:  2015-04-15       Impact factor: 4.359

Review 2.  Artificial Pancreas: Current Progress and Future Outlook in the Treatment of Type 1 Diabetes.

Authors:  Rozana Ramli; Monika Reddy; Nick Oliver
Journal:  Drugs       Date:  2019-07       Impact factor: 9.546

3.  Analyzing the Potential of Advanced Insulin Dosing Strategies in Patients With Type 2 Diabetes: Results From a Hybrid In Silico Study.

Authors:  Florian Reiterer; Matthias Reiter; Luigi Del Re; Merete Bechmann Christensen; Kirsten Nørgaard
Journal:  J Diabetes Sci Technol       Date:  2018-04-21

Review 4.  Diabetes Technology: Monitoring, Analytics, and Optimal Control.

Authors:  Boris Kovatchev
Journal:  Cold Spring Harb Perspect Med       Date:  2019-06-03       Impact factor: 6.915

5.  The International Diabetes Closed-Loop Study: Testing Artificial Pancreas Component Interoperability.

Authors:  Stacey M Anderson; Eyal Dassau; Dan Raghinaru; John Lum; Sue A Brown; Jordan E Pinsker; Mei Mei Church; Carol Levy; David Lam; Yogish C Kudva; Bruce Buckingham; Gregory P Forlenza; R Paul Wadwa; Lori Laffel; Francis J Doyle; J Hans DeVries; Eric Renard; Claudio Cobelli; Federico Boscari; Simone Del Favero; Boris P Kovatchev
Journal:  Diabetes Technol Ther       Date:  2019-01-16       Impact factor: 6.118

6.  Analysis of "Artificial Pancreas (AP) Systems for People With Type 2 Diabetes: Conception and Design of the European CLOSE Project".

Authors:  Andrew A Bremer; Guillermo Arreaza-Rubín
Journal:  J Diabetes Sci Technol       Date:  2019-01-19

Review 7.  Insulin Pump Therapy for Patients With Type 2 Diabetes Mellitus: Evidence, Current Barriers, and New Technologies.

Authors:  Guido Freckmann; Sina Buck; Delia Waldenmaier; Bernhard Kulzer; Oliver Schnell; Ulrich Gelchsheimer; Ralph Ziegler; Lutz Heinemann
Journal:  J Diabetes Sci Technol       Date:  2020-06-01

8.  Modelling endogenous insulin concentration in type 2 diabetes during closed-loop insulin delivery.

Authors:  Yue Ruan; Hood Thabit; Malgorzata E Wilinska; Roman Hovorka
Journal:  Biomed Eng Online       Date:  2015-03-04       Impact factor: 2.819

Review 9.  Identifying and meeting the challenges of insulin therapy in type 2 diabetes.

Authors:  Christopher Sorli; Michael K Heile
Journal:  J Multidiscip Healthc       Date:  2014-07-02

10.  The Artificial Pancreas in 2016: A Digital Treatment Ecosystem for Diabetes.

Authors:  Boris Kovatchev; William V Tamborlane; William T Cefalu; Claudio Cobelli
Journal:  Diabetes Care       Date:  2016-07       Impact factor: 19.112

View more