Literature DB >> 30126835

Diabetes Technology: Monitoring, Analytics, and Optimal Control.

Boris Kovatchev1.   

Abstract

Over the past 50 years, the diabetes technology field progressed remarkably through self-monitoring of blood glucose (SMBG), continuous subcutaneous insulin infusion (CSII), risk and variability analysis, mathematical models and computer simulation of the human metabolic system, real-time continuous glucose monitoring (CGM), and control algorithms driving closed-loop control systems known as the "artificial pancreas" (AP). This review follows these developments, beginning with an overview of the functioning of the human metabolic system in health and in diabetes and of its detailed quantitative network modeling. The review continues with a brief account of the first AP studies that used intravenous glucose monitoring and insulin infusion, and with notes about CSII and CGM-the technologies that made possible the development of contemporary AP systems. In conclusion, engineering lessons learned from AP research, and the clinical need for AP systems to prove their safety and efficacy in large-scale clinical trials, are outlined.
Copyright © 2019 Cold Spring Harbor Laboratory Press; all rights reserved.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 30126835      PMCID: PMC6546035          DOI: 10.1101/cshperspect.a034389

Source DB:  PubMed          Journal:  Cold Spring Harb Perspect Med        ISSN: 2157-1422            Impact factor:   6.915


  116 in total

Review 1.  Continuous glucose monitoring: roadmap for 21st century diabetes therapy.

Authors:  David C Klonoff
Journal:  Diabetes Care       Date:  2005-05       Impact factor: 19.112

Review 2.  Continuous glucose monitoring and closed-loop systems.

Authors:  R Hovorka
Journal:  Diabet Med       Date:  2006-01       Impact factor: 4.359

3.  The development of Biostator, a Glucose Controlled Insulin Infusion System (GCIIS).

Authors:  A H Clemens; P H Chang; R W Myers
Journal:  Horm Metab Res       Date:  1977       Impact factor: 2.936

Review 4.  Closed-loop and open-loop devices for blood glucose control in normal and diabetic subjects.

Authors:  J V Santiago; A H Clemens; W L Clarke; D M Kipnis
Journal:  Diabetes       Date:  1979-01       Impact factor: 9.461

5.  Fully integrated artificial pancreas in type 1 diabetes: modular closed-loop glucose control maintains near normoglycemia.

Authors:  Marc Breton; Anne Farret; Daniela Bruttomesso; Stacey Anderson; Lalo Magni; Stephen Patek; Chiara Dalla Man; Jerome Place; Susan Demartini; Simone Del Favero; Chiara Toffanin; Colleen Hughes-Karvetski; Eyal Dassau; Howard Zisser; Francis J Doyle; Giuseppe De Nicolao; Angelo Avogaro; Claudio Cobelli; Eric Renard; Boris Kovatchev
Journal:  Diabetes       Date:  2012-06-11       Impact factor: 9.461

6.  Manual closed-loop insulin delivery in children and adolescents with type 1 diabetes: a phase 2 randomised crossover trial.

Authors:  Roman Hovorka; Janet M Allen; Daniela Elleri; Ludovic J Chassin; Julie Harris; Dongyuan Xing; Craig Kollman; Tomas Hovorka; Anne Mette F Larsen; Marianna Nodale; Alessandra De Palma; Malgorzata E Wilinska; Carlo L Acerini; David B Dunger
Journal:  Lancet       Date:  2010-02-04       Impact factor: 79.321

7.  Outpatient glycemic control with a bionic pancreas in type 1 diabetes.

Authors:  Steven J Russell; Firas H El-Khatib; Manasi Sinha; Kendra L Magyar; Katherine McKeon; Laura G Goergen; Courtney Balliro; Mallory A Hillard; David M Nathan; Edward R Damiano
Journal:  N Engl J Med       Date:  2014-06-15       Impact factor: 91.245

8.  The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus.

Authors:  D M Nathan; S Genuth; J Lachin; P Cleary; O Crofford; M Davis; L Rand; C Siebert
Journal:  N Engl J Med       Date:  1993-09-30       Impact factor: 91.245

9.  Preventing hypoglycemia using predictive alarm algorithms and insulin pump suspension.

Authors:  Bruce Buckingham; Erin Cobry; Paula Clinton; Victoria Gage; Kimberly Caswell; Elizabeth Kunselman; Fraser Cameron; H Peter Chase
Journal:  Diabetes Technol Ther       Date:  2009-02       Impact factor: 6.118

10.  Adding heart rate signal to a control-to-range artificial pancreas system improves the protection against hypoglycemia during exercise in type 1 diabetes.

Authors:  Marc D Breton; Sue A Brown; Colleen Hughes Karvetski; Laura Kollar; Katarina A Topchyan; Stacey M Anderson; Boris P Kovatchev
Journal:  Diabetes Technol Ther       Date:  2014-04-04       Impact factor: 6.118

View more
  2 in total

1.  The Differential and Combined Action of Insulin Glargine and Lixisenatide on the Fasting and Postprandial Components of Glucose Control.

Authors:  Thibault Gautier; Guillermo Umpierrez; Eric Renard; Boris Kovatchev
Journal:  J Diabetes Sci Technol       Date:  2019-12-06

2.  Decreased complexity of glucose dynamics in diabetes in rhesus monkeys.

Authors:  Richard Raubertas; Jeremy Beech; Wendy Watson; Steven Fox; Scott Tiesma; David B Gilberto; Ashleigh Bone; Patricia A Rebbeck; Liza T Gantert; Stacey Conarello; Walter Knapp; Tasha Gray; Larry Handt; Cai Li
Journal:  Sci Rep       Date:  2019-02-05       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.