Katie L Pitts1, Marianne Fenech.
Abstract
It is desired to understand the effect of alginic acid sodium salt from brown algae (alginate) as a viscosity modifier on the behavior of blood in vitro using a micro-particle image velocimetry (µPIV) system. The effect of alginate on the shape of the velocity profile, the flow rate and the maximum velocity achieved in rectangular microchannels channels are measured. The channels were constructed of polydimethylsiloxane (PDMS), a biocompatible silicone. Porcine blood cells suspended in saline was used as the working fluid at twenty percent hematocrit (H = 20). While alginate was only found to have minimal effect on the maximum velocity and the flow rate achieved, it was found to significantly affect the shear rate at the wall by between eight to a hundred percent.Entities:
Mesh:
Substances:
Year: 2013 PMID: 24023655 PMCID: PMC3758353 DOI: 10.1371/journal.pone.0072909
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Results of the various test conditions for flow rate, shear rate and maximum centerline velocity where H is the hematocrit, is the programmed flow rate of the syringe pump, is the average flow rate calculated from the measured velocity profile, SD is the standard deviation, is the average measured shear rate at the wall, and is the average maximum velocity.
| Test | H |
|
| SD |
| SD |
| SD |
| (fluid) | (%) | ( | ( | (1/s) | (mm/s) | (mm/s) | ||
| blood |
|
|
|
|
|
|
| 0.000012 |
| with alginate |
|
|
|
|
|
|
| 0.000043 |
| blood |
|
|
|
|
|
|
| 0.000012 |
| with alginate |
|
|
|
|
|
|
| 0.000018 |
| blood |
|
|
|
|
|
|
| 0.000061 |
| with alginate |
|
|
|
|
|
|
| 0.000101 |
Microchannels are PDMS with dimensions of 40 µm×140 µm.
Figure 1Diagram of experimental µPIV set-up showing the optical path and microfluidic component placement.
Figure 2Comparison of the effect of alginate on the velocity profiles of blood with 20% hematocrit at various flow rates in a 140 µm wide, 40 µm tall PDMS channel.
Black line is data and red line is fitted two-parameter K-model.
Velocity profile characterization results of the various test conditions using two-parameter K model where H is the hematocrit, is the programmed flow rate of the syringe pump, is the average calculated maximum velocity in the channel, is the first shape parameter, SD is the standard deviation, and is the second shape parameter.