Literature DB >> 24023475

Pasteurella multocida infective endocarditis in an immunocompetent patient complicated by rhabdomyolysis and permanent hearing loss.

Nino Mikaberidz1, Eric Y Li, Cynthia C Taub.   

Abstract

Pasteurella multocida is an inhabitant of the oral cavity of a variety of livestock and domestic pet species, especially cats and dogs. The case reported illustrates a 60-year-old, immunocompetent female patient who presented with P. multocida sepsis and aortic valve endocarditis. This required surgical bioprosthetic aortic valve replacement. Investigation also found infection-induced rhabdomyolysis and permanent hearing loss, both previously unassociated with P. multocida infection.

Entities:  

Keywords:  Endocarditis; Pasteurella multocida; Rhabdomyolysis

Year:  2013        PMID: 24023475      PMCID: PMC3758082          DOI: 10.1016/j.jcdr.2013.02.006

Source DB:  PubMed          Journal:  J Cardiovasc Dis Res        ISSN: 0975-3583


  6 in total

1.  Pasteurella multocida endocarditis.

Authors:  Muhammad F Khan; Mohammad Reza Movahed; Jiyeon Jung
Journal:  J Heart Valve Dis       Date:  2012-03

2.  Isolated endocarditis of the pulmonary valve caused by Pasteurella multocida.

Authors:  S Graf; T Binder; M Heger; P Apfalter; N Simon; S Winkler
Journal:  Infection       Date:  2007-02       Impact factor: 3.553

Review 3.  Pasteurella multocida aortic valve endocarditis: case report and literature review.

Authors:  Georges Fayad; Thomas Modine; Samia Mokhtari; Laurence Legout; Christophe Decoene; Richard Azzaoui; Sharif Al-Ruzzeh; Ghassan Naja; Benoit Larrue; Fréderic Lecomte; Eric Senneville; Henri Warembourg
Journal:  J Heart Valve Dis       Date:  2003-03

4.  Fatal fulminant sepsis due to a cat bite in an immunocompromised patient.

Authors:  Ivana Harsanji Drenjancevic; Dubravka Ivic; Domagoj Drenjancevic; Josip Ivic; Boris Pelc; Dubravka Vukovic
Journal:  Wien Klin Wochenschr       Date:  2008       Impact factor: 1.704

5.  Pasteurella multocida endocarditis: report of a case.

Authors:  Yoshihiro Fukumoto; Yukinori Moriyama; Yoshifumi Iguro; Riichiro Toda; Akira Taira
Journal:  Surg Today       Date:  2002       Impact factor: 2.549

6.  First case of Pasteurella multocida endocarditis of the tricuspid valve: a favorable outcome following medical treatment.

Authors:  Mazen R Naba; George F Araj; Zeina A Kanafani; Souha S Kanj
Journal:  Int J Infect Dis       Date:  2009-01-03       Impact factor: 3.623

  6 in total
  4 in total

1.  Fatal multifocal Pasteurella multocida infection: a case report.

Authors:  Mathieu Guilbart; Elie Zogheib; Abdel Hakim Hchikat; Kahina Kirat; Linda Ferraz; Anne-Marie Guerin-Robardey; Faouzi Trojette; Mona Moubarak-Daher; Hervé Dupont
Journal:  BMC Res Notes       Date:  2015-07-02

2.  An angry cat causing Pasteurella multocida endocarditis and aortic valve replacement-A case report.

Authors:  Anders Ahlsson; Örjan Friberg; Jan Källman
Journal:  Int J Surg Case Rep       Date:  2016-05-19

3.  Rare but Fatal Pasteurella multocida Infective Endocarditis: A Case Report and Literature Review.

Authors:  Mohamed Mahmoud; Khadija El Kortbi; Mohamed I Abdalla; Sheila Habib
Journal:  Cureus       Date:  2022-03-08

Review 4.  Infective Endocarditis by Pasteurella Species: A Systematic Review.

Authors:  Angeliki Alifragki; Argyro Kontogianni; Ioanna Protopapa; Stella Baliou; Petros Ioannou
Journal:  J Clin Med       Date:  2022-08-27       Impact factor: 4.964

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.