Literature DB >> 24022575

The 3-min test does not provide a valid measure of critical power using the SRM isokinetic mode.

B Karsten1, S A Jobson2, J Hopker3, L Passfield3, C Beedie4.   

Abstract

Recent datas suggest that the mean power over the final 30 s of a 3-min all-out test is equivalent to Critical Power (CP) using the linear ergometer mode. The purpose of the present study was to identify whether this is also true using an "isokinetic mode". 13 cyclists performed: 1) a ramp test; 2) three 3-min all-out trials to establish End Power (EP) and work done above EP (WEP); and 3) 3 constant work rate trials to determine CP and the work done above CP (W') using the work-time (=CP1/W'1) and 1/time (=CP2/W'2) models. Coefficient of variation in EP was 4.45% between trials 1 and 2, and 4.29% between trials 2 and 3. Limits of Agreement for trials 1-2 and trials 2-3 were -2±38 W. Significant differences were observed between EP and CP1 (+37 W, P<0.001), between WEP and W'1(-6.2 kJ, P=0.001), between EP and CP2 (+31 W, P<0.001) and between WEP and W'2 (-4.2 kJ, P=0.006). Average SEE values for EP-CP1 and EP-CP2 of 7.1% and 6.6% respectively were identified. Data suggest that using an isokinetic mode 3-min all-out test, while yielding a reliable measure of EP, does not provide a valid measure of CP. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2013        PMID: 24022575     DOI: 10.1055/s-0033-1349093

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  6 in total

1.  A 'ramp-sprint' protocol to characterise indices of aerobic function and exercise intensity domains in a single laboratory test.

Authors:  Scott R Murgatroyd; Lindsey A Wylde; Daniel T Cannon; Susan A Ward; Harry B Rossiter
Journal:  Eur J Appl Physiol       Date:  2014-06-03       Impact factor: 3.078

2.  Critical speed and finite distance capacity: norms for athletic and non-athletic groups.

Authors:  Mark Kramer; E J Thomas; R W Pettitt
Journal:  Eur J Appl Physiol       Date:  2020-02-22       Impact factor: 3.078

3.  Anaerobic work capacity in cycling: the effect of computational method.

Authors:  Erik P Andersson; Philipp Bachl; Anna Schmuttermair; Craig A Staunton; Thomas L Stöggl
Journal:  Eur J Appl Physiol       Date:  2022-09-17       Impact factor: 3.346

Review 4.  Determination of Critical Power Using Different Possible Approaches among Endurance Athletes: A Review.

Authors:  Lucie Lipková; Michal Kumstát; Ivan Struhár
Journal:  Int J Environ Res Public Health       Date:  2022-06-21       Impact factor: 4.614

5.  The 3-min all-out test is valid for determining critical power but not anaerobic work capacity in tethered running.

Authors:  Maria Carolina Traina Gama; Ivan Gustavo Masselli Dos Reis; Filipe Antônio de Barros Sousa; Claudio Alexandre Gobatto
Journal:  PLoS One       Date:  2018-02-14       Impact factor: 3.240

6.  Comparison of parameters derived from a three-minute all-out test with classical benchmarks for running exercise.

Authors:  Filipe A B Sousa; Fúlvia B Manchado-Gobatto; Natália A Rodrigues; Claudio A Gobatto
Journal:  PLoS One       Date:  2022-03-24       Impact factor: 3.240