Literature DB >> 24018542

Design and implementation of a film dosimetry audit tool for comparison of planned and delivered dose distributions in high dose rate (HDR) brachytherapy.

Antony L Palmer1, Chris Lee, Ailsa J Ratcliffe, David Bradley, Andrew Nisbet.   

Abstract

A novel phantom is presented for 'full system' dosimetric audit comparing planned and delivered dose distributions in HDR gynaecological brachytherapy, using clinical treatment applicators. The brachytherapy applicator dosimetry test object consists of a near full-scatter water tank with applicator and film supports constructed of Solid Water, accommodating any typical cervix applicator. Film dosimeters are precisely held in four orthogonal planes bisecting the intrauterine tube, sampling dose distributions in the high risk clinical target volume, points A and B, bladder, rectum and sigmoid. The applicator position is fixed prior to CT scanning and through treatment planning and irradiation. The CT data is acquired with the applicator in a near clinical orientation to include applicator reconstruction in the system test. Gamma analysis is used to compare treatment planning system exported RTDose grid with measured multi-channel film dose maps. Results from two pilot audits are presented, using Ir-192 and Co-60 HDR sources, with a mean gamma passing rate of 98.6% using criteria of 3% local normalization and 3 mm distance to agreement (DTA). The mean DTA between prescribed dose and measured film dose at point A was 1.2 mm. The phantom was funded by IPEM and will be used for a UK national brachytherapy dosimetry audit.

Entities:  

Mesh:

Year:  2013        PMID: 24018542     DOI: 10.1088/0031-9155/58/19/6623

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  12 in total

Review 1.  Dosimetric audit in brachytherapy.

Authors:  A L Palmer; D A Bradley; A Nisbet
Journal:  Br J Radiol       Date:  2014-05-06       Impact factor: 3.039

2.  Film based verification of calculation algorithms used for brachytherapy planning-getting ready for upcoming challenges of MBDCA.

Authors:  Grzegorz Zwierzchowski; Grzegorz Bielęda; Janusz Skowronek; Magdalena Mazur
Journal:  J Contemp Brachytherapy       Date:  2016-08-16

3.  Inter-departmental dosimetry audits - development of methods and lessons learned.

Authors:  David J Eaton; Steve Bolton; Russell A S Thomas; Catharine H Clark
Journal:  J Med Phys       Date:  2015 Oct-Dec

4.  Verification of high-dose-rate brachytherapy treatment planning dose distribution using liquid-filled ionization chamber array.

Authors:  A B Mohamed Yoosuf; Prakash Jeevanandam; Glenn Whitten; Geraldine Workman; Conor K McGarry
Journal:  J Contemp Brachytherapy       Date:  2018-04-30

5.  Evaluation and mitigation of potential errors in radiochromic film dosimetry due to film curvature at scanning.

Authors:  Antony L Palmer; David A Bradley; Andrew Nisbet
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

6.  Real-time dosimetry with radiochromic films.

Authors:  Pierluigi Casolaro; Luigi Campajola; Giovanni Breglio; Salvatore Buontempo; Marco Consales; Andrea Cusano; Antonello Cutolo; Francesco Di Capua; Francesco Fienga; Patrizio Vaiano
Journal:  Sci Rep       Date:  2019-03-29       Impact factor: 4.379

7.  Quality Assurance Procedures based on Dosimetric, Gamma Analysis as a Fast Reliable Tool for Commissioning Brachytherapy Treatment Planning Systems.

Authors:  Grzegorz Zwierzchowski; Grzegorz Bieleda; Janusz Skowronek
Journal:  Radiol Oncol       Date:  2017-11-29       Impact factor: 2.991

8.  Independent assessment of source position for gynecological applicator in high-dose-rate brachytherapy.

Authors:  Hiroyuki Okamoto; Satoshi Nakamura; Shie Nishioka; Kotaro Iijima; Akihisa Wakita; Yukinao Abe; Naoki Tohyama; Shinji Kawamura; Toshiyuki Minemura; Jun Itami
Journal:  J Contemp Brachytherapy       Date:  2017-10-19

9.  Evaluation and implementation of triple-channel radiochromic film dosimetry in brachytherapy.

Authors:  Antony L Palmer; David Bradley; Andrew Nisbet
Journal:  J Appl Clin Med Phys       Date:  2014-07-08       Impact factor: 2.102

10.  End-to-end test for computed tomography-based high-dose-rate brachytherapy.

Authors:  Fabian Krause; Franziska Risske; Susann Bohn; Marc Delaperriere; Jürgen Dunst; Frank-André Siebert
Journal:  J Contemp Brachytherapy       Date:  2018-12-28