Literature DB >> 24018122

Radiofrequency heating and magnetic field interactions of fixed partial dentures during 3-tesla magnetic resonance imaging.

Simel Ayyıldız1, Kıvanç Kamburoğlu, Cumhur Sipahi, Sema Murat, Serkan Görgülü, Bülent Pişkin.   

Abstract

OBJECTIVE: This study evaluated the heating and magnetic field interactions of fixed partial dentures in a 3-Tesla (3T) magnetic resonance imaging (MRI) environment. STUDY
DESIGN: Three substructure materials (Co-Cr, Ni-Cr, ZrO₂) were used to fabricate twelve 4-retained bridges and 12 crowns. Specimens were evaluated at 3T for radiofrequency heating and magnetic field interactions. One-way analysis of variance (ANOVA) test was used to compare continuous variables of temperature change. Significance was set at P < .05. Translational attraction and torque values of specimens were also evaluated.
RESULTS: None of the groups exhibited excessive heating (mean temperature change, < 1.4 °C), with maximum increase at the end of the T-1. Moreover, in all groups, only relatively minor magnetic field interactions that would not cause movement in situ were observed.
CONCLUSION: The study findings indicated that patients with fixed partial dentures (single crown or bridge) fabricated from Co-Cr, Ni-Cr, and zirconia substructures may safely undergo MRI at up to 3T.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24018122     DOI: 10.1016/j.oooo.2013.06.035

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol


  4 in total

1.  Effect of orthodontic brackets and different wires on radiofrequency heating and magnetic field interactions during 3.0-T MRI.

Authors:  Seyed Mj Mortazavi; Maryam Paknahad
Journal:  Dentomaxillofac Radiol       Date:  2015-10-15       Impact factor: 2.419

2.  Effect of magnetic resonance imaging on microleakage of amalgam restorations: an in vitro study.

Authors:  S M J Mortazavi; Maryam Paknahad
Journal:  Dentomaxillofac Radiol       Date:  2015-08-17       Impact factor: 2.419

3.  Effect of orthodontic brackets and different wires on radiofrequency heating and magnetic field interactions during 3-T MRI.

Authors:  S Görgülü; S Ayyildiz; K Kamburoglu; S Gökçe; T Ozen
Journal:  Dentomaxillofac Radiol       Date:  2013-11-20       Impact factor: 2.419

4.  Compatibility of endoclips in the gastrointestinal tract with magnetic resonance imaging.

Authors:  Dong Yeol Shin; Sumi Park; Ain Kim; Eung-Sam Kim; Han Ho Jeon
Journal:  Sci Rep       Date:  2020-10-06       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.