Literature DB >> 24015027

Shock-induced collapse of a bubble inside a deformable vessel.

Vedran Coralic1, Tim Colonius.   

Abstract

Shockwave lithotripsy repeatedly focuses shockwaves on kidney stones to induce their fracture, partially through cavitation erosion. A typical side effect of the procedure is hemorrhage, which is potentially the result of the growth and collapse of bubbles inside blood vessels. To identify the mechanisms by which shock-induced collapse could lead to the onset of injury, we study an idealized problem involving a preexisting bubble in a deformable vessel. We utilize a high-order accurate, shock- and interface-capturing, finite-volume scheme and simulate the three-dimensional shock-induced collapse of an air bubble immersed in a cylindrical water column which is embedded in a gelatin/water mixture. The mixture is a soft tissue simulant, 10% gelatin by weight, and is modeled by the stiffened gas equation of state. The bubble dynamics of this model configuration are characterized by the collapse of the bubble and its subsequent jetting in the direction of the propagation of the shockwave. The vessel wall, which is defined by the material interface between the water and gelatin/water mixture, is invaginated by the collapse and distended by the impact of the jet. The present results show that the highest measured pressures and deformations occur when the volumetric confinement of the bubble is strongest, the bubble is nearest the vessel wall and/or the angle of incidence of the shockwave reduces the distance between the jet tip and the nearest vessel surface. For a particular case considered, the 40 MPa shockwave utilized in this study to collapse the bubble generated a vessel wall pressure of almost 450 MPa and produced both an invagination and distention of nearly 50% of the initial vessel radius on a 𝒪(10) ns timescale. These results are indicative of the significant potential of shock-induced collapse to contribute to the injury of blood vessels in shockwave lithotripsy.

Entities:  

Keywords:  Shockwave lithotripsy; cavitation bubbles; gas bubbles; renal injury; shock-induced collapse; vessel rupture

Year:  2013        PMID: 24015027      PMCID: PMC3763519          DOI: 10.1016/j.euromechflu.2013.01.003

Source DB:  PubMed          Journal:  Eur J Mech B Fluids        ISSN: 0997-7546            Impact factor:   2.183


  20 in total

1.  Material characterization of the pig kidney in relation with the biomechanical analysis of renal trauma.

Authors:  M Farshad; M Barbezat; P Flüeler; F Schmidlin; P Graber; P Niederer
Journal:  J Biomech       Date:  1999-04       Impact factor: 2.712

Review 2.  Compilation of empirical ultrasonic properties of mammalian tissues. II.

Authors:  S A Goss; R L Johnston; F Dunn
Journal:  J Acoust Soc Am       Date:  1980-07       Impact factor: 1.840

3.  Cavitation bubble cluster activity in the breakage of kidney stones by lithotripter shockwaves.

Authors:  Yuriy A Pishchalnikov; Oleg A Sapozhnikov; Michael R Bailey; James C Williams; Robin O Cleveland; Tim Colonius; Lawrence A Crum; Andrew P Evan; James A McAteer
Journal:  J Endourol       Date:  2003-09       Impact factor: 2.942

4.  Direct observations of ultrasound microbubble contrast agent interaction with the microvessel wall.

Authors:  Charles F Caskey; Susanne M Stieger; Shengping Qin; Paul A Dayton; Katherine W Ferrara
Journal:  J Acoust Soc Am       Date:  2007-08       Impact factor: 1.840

5.  Interaction of lithotripter shockwaves with single inertial cavitation bubbles.

Authors:  Evert Klaseboer; Siew Wan Fong; Cary K Turangan; Boo Cheong Khoo; Andrew J Szeri; Michael L Calvisi; Georgy N Sankin; Pei Zhong
Journal:  J Fluid Mech       Date:  2007       Impact factor: 3.627

6.  Blood vessel deformations on microsecond time scales by ultrasonic cavitation.

Authors:  Hong Chen; Wayne Kreider; Andrew A Brayman; Michael R Bailey; Thomas J Matula
Journal:  Phys Rev Lett       Date:  2011-01-18       Impact factor: 9.161

7.  Shock wave-bubble interaction near soft and rigid boundaries during lithotripsy: numerical analysis by the improved ghost fluid method.

Authors:  Kazumichi Kobayashi; Tetsuya Kodama; Hiroyuki Takahira
Journal:  Phys Med Biol       Date:  2011-09-15       Impact factor: 3.609

8.  Blood vessel rupture by cavitation.

Authors:  Hong Chen; Andrew A Brayman; Michael R Bailey; Thomas J Matula
Journal:  Urol Res       Date:  2010-08-02

9.  Numerical simulations of non-spherical bubble collapse.

Authors:  Eric Johnsen; Tim Colonius
Journal:  J Fluid Mech       Date:  2009-06-01       Impact factor: 3.627

10.  Shock-induced collapse of a gas bubble in shockwave lithotripsy.

Authors:  Eric Johnsen; Tim Colonius
Journal:  J Acoust Soc Am       Date:  2008-10       Impact factor: 1.840

View more
  6 in total

1.  Optimization of low-frequency low-intensity ultrasound-mediated microvessel disruption on prostate cancer xenografts in nude mice using an orthogonal experimental design.

Authors:  Y U Yang; Wenkun Bai; Yini Chen; Yanduan Lin; Bing Hu
Journal:  Oncol Lett       Date:  2015-09-17       Impact factor: 2.967

2.  Shock-Induced Damage and Dynamic Fracture in Cylindrical Bodies Submerged in Liquid.

Authors:  S Cao; Y Zhang; D Liao; P Zhong; K G Wang
Journal:  Int J Solids Struct       Date:  2019-04-02       Impact factor: 3.900

3.  Finite-volume WENO scheme for viscous compressible multicomponent flows.

Authors:  Vedran Coralic; Tim Colonius
Journal:  J Comput Phys       Date:  2014-10-01       Impact factor: 3.553

4.  Spiral computed tomography evaluation of rabbit VX2 hepatic tumors treated with 20 kHz ultrasound and microbubbles.

Authors:  Zhi-Yong Shen; Chun Liu; Ming-Feng Wu; Hai-Feng Shi; Yu-Feng Zhou; Wei Zhuang; Gan-Lin Xia
Journal:  Oncol Lett       Date:  2017-07-08       Impact factor: 2.967

5.  Low-frequency ultrasound-mediated microvessel disruption combined with docetaxel to treat prostate carcinoma xenografts in nude mice: A novel type of chemoembolization.

Authors:  Yu Yang; Wenkun Bai; Yini Chen; Shuliang Nan; Yanduan Lin; Tao Ying; Bing Hu
Journal:  Oncol Lett       Date:  2016-06-13       Impact factor: 2.967

6.  MFC: An open-source high-order multi-component, multi-phase, and multi-scale compressible flow solver.

Authors:  Spencer H Bryngelson; Kevin Schmidmayer; Vedran Coralic; Jomela C Meng; Kazuki Maeda; Tim Colonius
Journal:  Comput Phys Commun       Date:  2020-05-23       Impact factor: 4.717

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.