Literature DB >> 10213032

Material characterization of the pig kidney in relation with the biomechanical analysis of renal trauma.

M Farshad1, M Barbezat, P Flüeler, F Schmidlin, P Graber, P Niederer.   

Abstract

The objective of this study was an investigation of the material properties of the fresh pig kidney and parametric characterization of its elastic and inelastic material behavior. The material investigation included density measurements, uniaxial as well as three-dimensional compression tests, tensile tests. and shear tests on the samples extracted from the fresh pig kidney. For comparison, density measurements on a number of soft synthetic materials were also performed. Compression tests on the radial and the tangential specimens from the cortex tissue were performed at various loading rates. Three-axial compression tests were performed on the cortex tissues placed in a compression chamber. Shear tests were performed by punching a cylinder into a slice of the cortex. Tensile tests were carried out on the outer capsule. For characterization of the material behavior, a non-linear theoretical simulation based on a two parameter Blatz model was used. For characterization of the time-dependent behavior of the pig kidney cortex, a four-parameter linear viscoelastic model was employed. From the present experimental and theoretical studies, a number of conclusions were derived: (1) The general behavior of the pig kidney cortex samples under compression showed the general non-linear features typical of the soft tissues; the stress strain diagram was composed of a very flat part at very low stress level to about 30% relative deformation which was followed by a steeply rising stiffening leading to the radial rupture of samples marked by a maximum nominal rupture strain of about 50%. (2) The uniaxial compression tests on the radial and the tangential samples from the cortex tissue showed an increase of the rupture stress with the increase in the loading rate, but a decrease in the related rupture strain. (3) The long-term uniaxial compression tests on the cortex specimens under sustained constant load showed an instantaneous deformation followed by a creep response which eventually approached an asymptote. (4) Simulation of the non-linear material behavior of the cortex tissue under uniaxial compression by the Blatz model gave two pairs of material parameters for the cortex in the radial and the tangential directions. Furthermore, fitting of the assumed four-parameter linear viscoelastic model with the experimental data resulted in the viscoelastic material parameters.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10213032     DOI: 10.1016/s0021-9290(98)00180-8

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  17 in total

1.  Strain rate-dependent viscohyperelastic constitutive modeling of bovine liver tissue.

Authors:  Esra Roan; Kumar Vemaganti
Journal:  Med Biol Eng Comput       Date:  2010-11-04       Impact factor: 2.602

2.  Patient-specific biomechanical model as whole-body CT image registration tool.

Authors:  Mao Li; Karol Miller; Grand Roman Joldes; Barry Doyle; Revanth Reddy Garlapati; Ron Kikinis; Adam Wittek
Journal:  Med Image Anal       Date:  2015-01-30       Impact factor: 8.545

3.  On the unimportance of constitutive models in computing brain deformation for image-guided surgery.

Authors:  Adam Wittek; Trent Hawkins; Karol Miller
Journal:  Biomech Model Mechanobiol       Date:  2008-02-02

4.  Suppression of shocked-bubble expansion due to tissue confinement with application to shock-wave lithotripsy.

Authors:  Jonathan B Freund
Journal:  J Acoust Soc Am       Date:  2008-05       Impact factor: 1.840

5.  Viscoelastic characterization of extraocular Z-myotomy.

Authors:  Andrew Shin; Lawrence Yoo; Joseph L Demer
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-12-04       Impact factor: 4.799

6.  Shock-induced collapse of a bubble inside a deformable vessel.

Authors:  Vedran Coralic; Tim Colonius
Journal:  Eur J Mech B Fluids       Date:  2013-07       Impact factor: 2.183

7.  Viscoelastic properties of bovine orbital connective tissue and fat: constitutive models.

Authors:  Lawrence Yoo; Vijay Gupta; Choongyeop Lee; Pirouz Kavehpore; Joseph L Demer
Journal:  Biomech Model Mechanobiol       Date:  2011-01-05

8.  Estimating zero-strain states of very soft tissue under gravity loading using digital image correlation.

Authors:  Zhan Gao; Jaydev P Desai
Journal:  Med Image Anal       Date:  2009-11-14       Impact factor: 8.545

9.  Shearwave dispersion ultrasound vibrometry (SDUV) on swine kidney.

Authors:  Carolina Amador; Matthew W Urban; Shigao Chen; James F Greenleaf
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-12       Impact factor: 2.725

10.  Quasilinear viscoelastic behavior of bovine extraocular muscle tissue.

Authors:  Lawrence Yoo; Hansang Kim; Vijay Gupta; Joseph L Demer
Journal:  Invest Ophthalmol Vis Sci       Date:  2009-04-08       Impact factor: 4.799

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.