Literature DB >> 24014676

Hemodynamic effects of implanting a unidirectional valve in the inferior vena cava of the Fontan circulation pathway: an in vitro investigation.

Arvind Santhanakrishnan1, Kevin O Maher, Elaine Tang, Reza H Khiabani, Jacob Johnson, Ajit P Yoganathan.   

Abstract

The Fontan surgical procedure used for treating patients with single ventricle congenital heart disorders results in a total cavopulmonary connection (TCPC) of the vena cavae to the pulmonary arteries (PAs). Sluggish TCPC flow and elevated hepatic venous pressures are commonly observed in this altered physiology, which in turn can lead to long-term complications including liver congestion and cirrhosis. The hypothesis of this study is that placement of a unidirectional valve within the inferior vena cava (IVC) will improve hemodynamics of the Fontan circulation by preventing retrograde flow and lowering hepatic venous pressure. An in vitro experimental setup consisting of an idealized TCPC model with flexible walls was used for investigation, and a bovine venous valve was inserted in the IVC below the TCPC. Pressure fluctuations were introduced in the flow through the model to simulate venous pulsatility. Hemodynamics of baseline and valve-implanted conditions were compared across total caval flows ranging from 1.0 to 2.5 l/min with varying caval flow distributions. The results indicated that valve closure occurred for 15-20% of the total cycle, with consequent reduction in the upstream hepatic venous pressure by 5 to 10 mmHg. Energy loss (EL) through the TCPC was lowered with valve implantation to 20-50% of baseline, occurring across all flow conditions considered with mean caval and PA pressures greater than 10 mmHg. The results of this in vitro modeling suggest that IVC valve placement has the potential to improve hemodynamics in the Fontan circulation by decreasing hepatic venous hypertension and EL.

Entities:  

Keywords:  Fontan circulation; hepatic venous hypertension; in vitro Fontan model; single ventricle; transcatheter valve

Mesh:

Year:  2013        PMID: 24014676     DOI: 10.1152/ajpheart.00351.2013

Source DB:  PubMed          Journal:  Am J Physiol Heart Circ Physiol        ISSN: 0363-6135            Impact factor:   4.733


  7 in total

1.  Non-dimensional physics of pulsatile cardiovascular networks and energy efficiency.

Authors:  Berk Yigit; Kerem Pekkan
Journal:  J R Soc Interface       Date:  2016-01       Impact factor: 4.118

2.  The Advantages of Viscous Dissipation Rate over Simplified Power Loss as a Fontan Hemodynamic Metric.

Authors:  Zhenglun Alan Wei; Michael Tree; Phillip M Trusty; Wenjun Wu; Shelly Singh-Gryzbon; Ajit Yoganathan
Journal:  Ann Biomed Eng       Date:  2017-11-01       Impact factor: 3.934

3.  Using a Novel In Vitro Fontan Model and Condition-Specific Real-Time MRI Data to Examine Hemodynamic Effects of Respiration and Exercise.

Authors:  Michael Tree; Zhenglun Alan Wei; Phillip M Trusty; Vrishank Raghav; Mark Fogel; Kevin Maher; Ajit Yoganathan
Journal:  Ann Biomed Eng       Date:  2017-10-24       Impact factor: 3.934

4.  In vitro validation of a self-driving aortic-turbine venous-assist device for Fontan patients.

Authors:  Kerem Pekkan; Ibrahim Basar Aka; Ece Tutsak; Erhan Ermek; Haldun Balim; Ismail Lazoglu; Riza Turkoz
Journal:  J Thorac Cardiovasc Surg       Date:  2018-03-11       Impact factor: 5.209

5.  Heart beat but not respiration is the main driving force of the systemic venous return in the Fontan circulation.

Authors:  Dominik Daniel Gabbert; Christopher Hart; Michael Jerosch-Herold; Philip Wegner; Mona Salehi Ravesh; Inga Voges; Ines Kristo; Abdullah A L Bulushi; Jens Scheewe; Arash Kheradvar; Hans-Heiner Kramer; Carsten Rickers
Journal:  Sci Rep       Date:  2019-02-14       Impact factor: 4.379

Review 6.  Transcatheter interventions in patients with a Fontan circulation: Current practice and future developments.

Authors:  Zakaria Jalal; Marc Gewillig; Younes Boudjemline; Patrice Guérin; Mara Pilati; Gianfranco Butera; Sophie Malekzadeh-Milani; Martina Avesani; Jean-Benoit Thambo
Journal:  Front Pediatr       Date:  2022-08-30       Impact factor: 3.569

7.  Control of respiration-driven retrograde flow in the subdiaphragmatic venous return of the Fontan circulation.

Authors:  Marija Vukicevic; Timothy Conover; Michael Jaeggli; Jian Zhou; Giancarlo Pennati; Tain-Yen Hsia; Richard S Figliola
Journal:  ASAIO J       Date:  2014 Jul-Aug       Impact factor: 2.872

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.