Literature DB >> 24013910

Load applied on bone-anchored transfemoral prosthesis: characterization of a prosthesis-a pilot study.

Laurent Frossard1, Eva Häggström, Kerstin Hagberg, Rickard Brånemark.   

Abstract

The objectives of this study were to (1) record the inner-prosthesis loading during activities of daily living (ADLs), (2) present a set of variables comparing loading data, and (3) provide an example of characterization of two prostheses. The load was measured at 200 Hz using a multi-axial transducer mounted between the residuum and the knee of an individual with unilateral transfemoral amputation fitted with a bone-anchored prosthesis. The load was measured while using two different prosthetic knees, mechanical (PRO1) and micro processor-controlled (PRO2), during six ADLs. The characterization of the prostheses was achieved using a set of variables split into four categories, including temporal characteristics, maximum loading, loading slopes, and impulse. Approximately 360 gait cycles were analyzed for each prosthesis. PRO1 showed a cadence improved by 19% and 7%, a maximum force on the long axis reduced by 11% and 19%, and an impulse reduced by 32% and 15% during descent of incline and stairs compared with PRO2, respectively. This work confirmed that the proposed apparatus and characterization can reveal how changes of prosthetic components are translated into inner-prosthetic loading.

Entities:  

Mesh:

Year:  2013        PMID: 24013910     DOI: 10.1682/jrrd.2012.04.0062

Source DB:  PubMed          Journal:  J Rehabil Res Dev        ISSN: 0748-7711


  10 in total

1.  An animal model to evaluate skin-implant-bone integration and gait with a prosthesis directly attached to the residual limb.

Authors:  Brad J Farrell; Boris I Prilutsky; Robert S Kistenberg; John F Dalton; Mark Pitkin
Journal:  Clin Biomech (Bristol, Avon)       Date:  2013-12-23       Impact factor: 2.063

Review 2.  [Transcutaneous osseointegrated prosthesis (TOP) after limb amputation : Status quo and perspectives].

Authors:  Christian Willy; Christian Krettek
Journal:  Unfallchirurg       Date:  2017-05       Impact factor: 1.000

3.  Kinetics of individual limbs during level and slope walking with a unilateral transtibial bone-anchored prosthesis in the cat.

Authors:  Joshua R Jarrell; Brad J Farrell; Robert S Kistenberg; John F Dalton; Mark Pitkin; Boris I Prilutsky
Journal:  J Biomech       Date:  2018-05-23       Impact factor: 2.712

4.  Development of a Procedure for the Government Provision of Bone-Anchored Prosthesis Using Osseointegration in Australia.

Authors:  Laurent Frossard; Gregory Merlo; Tanya Quincey; Brendan Burkett; Debra Berg
Journal:  Pharmacoecon Open       Date:  2017-12

5.  Inter-participant variability data in characterization of anthropomorphicity of prosthetic feet fitted to bone-anchored transtibial prosthesis.

Authors:  Laurent Frossard; Barry Leech; Mark Pitkin
Journal:  Data Brief       Date:  2019-07-23

6.  Loading characteristics data applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with state-of-the-art components during daily activities.

Authors:  Laurent Frossard; Stefan Laux; Marta Geada; Peter Paul Heym; Knut Lechler
Journal:  Data Brief       Date:  2022-02-10

7.  Survey data on the quality of life of consumers fitted with osseointegrated fixation and bone-anchored limb prostheses provided by government organization.

Authors:  Laurent Frossard; Luciann Ferrada; Debra Berg
Journal:  Data Brief       Date:  2019-09-17

8.  Loading characteristics data applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with basic components during daily activities.

Authors:  Laurent Frossard
Journal:  Data Brief       Date:  2019-09-11

9.  Inter-participant variability data in loading applied on osseointegrated implant by transtibial bone-anchored prostheses during daily activities.

Authors:  Laurent Frossard; Barry Leech; Mark Pitkin
Journal:  Data Brief       Date:  2019-09-20

10.  Safety, prosthesis wearing time and health-related quality of life of lower extremity bone-anchored prostheses using a press-fit titanium osseointegration implant: A prospective one-year follow-up cohort study.

Authors:  R Atallah; H van de Meent; L Verhamme; J P Frölke; R A Leijendekkers
Journal:  PLoS One       Date:  2020-03-09       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.