Literature DB >> 24013825

Noninvasive control of the power transferred to an implanted device by an ultrasonic transcutaneous energy transfer link.

Doron Shmilovitz, Shaul Ozeri, Chua-Chin Wang, Boaz Spivak.   

Abstract

Ultrasonic transcutaneous energy transfer is an effective method for powering implanted devices noninvasively. Nevertheless, the amount of power harvested by the implanted receiver is sensitive to the distance and orientation of the external transmitting transducer attached to the skin with respect to the implanted receiving transducer. This paper describes an ultrasonic power transfer link whose harvested power is controlled by an inductive link. A small (5 μF) storage capacitor voltage, which is part of the implanted unit, is allowed to swing between 3.8 and 3.5 V using hysteretic control. The two control states are indicated by excitation (while the implanted storage capacitor voltage decreases) or the absence of excitation of an implanted coil that is magnetically coupled to an external coil attached to the skin surface. A 35 mW Ultrasonic Transcutaneous Energy Transfer link was fabricated using two piezoelectric transducers of equal size (Fuji Ceramics C-2 PZT disc 15 mm × 3 mm) operated at a vibration frequency of 720 kHz. By applying the proposed hysteretic control, the captured power was effectively regulated for implantation depths of up to 85 mm.

Entities:  

Mesh:

Year:  2013        PMID: 24013825     DOI: 10.1109/TBME.2013.2280460

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  5 in total

1.  Acoustic metasurface with hybrid resonances.

Authors:  Guancong Ma; Min Yang; Songwen Xiao; Zhiyu Yang; Ping Sheng
Journal:  Nat Mater       Date:  2014-06-01       Impact factor: 43.841

2.  A Wirelessly-Powered Homecage With Segmented Copper Foils and Closed-Loop Power Control.

Authors:  S Abdollah Mirbozorgi; Yaoyao Jia; Daniel Canales; Maysam Ghovanloo
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2016-09-16       Impact factor: 3.833

3.  Distributed sensor and actuator networks for closed-loop bioelectronic medicine.

Authors:  Gauri Bhave; Joshua C Chen; Amanda Singer; Aditi Sharma; Jacob T Robinson
Journal:  Mater Today (Kidlington)       Date:  2021-03-06       Impact factor: 26.943

Review 4.  Automatic frequency controller for power amplifiers used in bio-implanted applications: issues and challenges.

Authors:  Mahammad A Hannan; Hussein A Hussein; Saad Mutashar; Salina A Samad; Aini Hussain
Journal:  Sensors (Basel)       Date:  2014-12-11       Impact factor: 3.576

Review 5.  Adaptive Transcutaneous Power Transfer to Implantable Devices: A State of the Art Review.

Authors:  Kara N Bocan; Ervin Sejdić
Journal:  Sensors (Basel)       Date:  2016-03-18       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.