Literature DB >> 24010069

Indirect Radionuclide Coronary Angiography to Evaluate Gradients of Myocardial Blood Flow and Flow Reserve Through Coronary Stenosis Using N-13 Ammonia PET/CT.

Hyun-Sik Kim1, Sang-Geon Cho, Ju Han Kim, Hee-Seung Bom.   

Abstract

Although quantitative evaluation of myocardial blood flow (MBF) and myocardial flow reserve (MFR) has been perceived as an attractive advantage of positron emission tomography (PET) over other cardiac imaging technologies, application of the information to specific coronary lesions is a difficult task for nuclear cardiologists. We hypothesized that changes in MBF and MFR over a coronary lesion could be identified by use of a hybrid technology of CT coronary angiography (CTCA) and N-13 ammonia PET. To evaluate this hypothesis, we measured the gradient of MBF and MFR through coronary stenosis in seven patients (M:F=3:4, median age 56 years) with coronary artery disease who underwent N-13 ammonia PET, CTCA, and interventional coronary angiography. Two patients had proximal left anterior descending (LAD) coronary artery disease and five patients had mid to distal LAD disease. Mean global stress and rest MBF were 2.62±0.58 and 1.03±0.19 ml/min/g, respectively. Mean global MFR was 2.6±0.73. Regional stress and rest MBF in the LAD territory were 2.36±0.75 and 0.96±0.21 ml/min/g, respectively. Regional MFR in the LAD territory was 2.55±0.83 ml/min/g. Stress MBF changed dramatically according to the location of coronary stenosis. It dropped acutely in proximal lesions, whereas it diminished gradually in mid to distal lesions. In conclusion, by use of a hybrid technology of CTCA and PET, it was feasible to make a direct correlation of coronary lesions with the gradient of MFR and CFR through coronary stenosis, which indicated the severity of the coronary lesion. We named this technique indirect radionuclide coronary angiography.

Entities:  

Keywords:  Coronary angiography; Mycocardium; Radionuclide imaging

Year:  2013        PMID: 24010069      PMCID: PMC3759685          DOI: 10.4068/cmj.2013.49.2.69

Source DB:  PubMed          Journal:  Chonnam Med J        ISSN: 2233-7393


  23 in total

1.  Diagnostic value of 13N-ammonia myocardial perfusion PET: added value of myocardial flow reserve.

Authors:  Michael Fiechter; Jelena R Ghadri; Cathérine Gebhard; Tobias A Fuchs; Aju P Pazhenkottil; Rene N Nkoulou; Bernhard A Herzog; Christophe A Wyss; Oliver Gaemperli; Philipp A Kaufmann
Journal:  J Nucl Med       Date:  2012-06-29       Impact factor: 10.057

2.  Prediction of short-term cardiovascular events using quantification of global myocardial flow reserve in patients referred for clinical 82Rb PET perfusion imaging.

Authors:  Kenji Fukushima; Mehrbod S Javadi; Takahiro Higuchi; Riikka Lautamäki; Jennifer Merrill; Stephan G Nekolla; Frank M Bengel
Journal:  J Nucl Med       Date:  2011-04-15       Impact factor: 10.057

3.  Noninvasive quantification of regional blood flow in the human heart using N-13 ammonia and dynamic positron emission tomographic imaging.

Authors:  G D Hutchins; M Schwaiger; K C Rosenspire; J Krivokapich; H Schelbert; D E Kuhl
Journal:  J Am Coll Cardiol       Date:  1990-04       Impact factor: 24.094

4.  Validation of a new cardiac image fusion software for three-dimensional integration of myocardial perfusion SPECT and stand-alone 64-slice CT angiography.

Authors:  Oliver Gaemperli; Tiziano Schepis; Victor Kalff; Mehdi Namdar; Ines Valenta; Laurent Stefani; Lotus Desbiolles; Sebastian Leschka; Lars Husmann; Hatem Alkadhi; Philipp A Kaufmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-01-24       Impact factor: 9.236

5.  Prognostic value of 64-slice cardiac computed tomography severity of coronary artery disease, coronary atherosclerosis, and left ventricular ejection fraction.

Authors:  Benjamin J W Chow; George A Wells; Li Chen; Yeung Yam; Paul Galiwango; Arun Abraham; Tej Sheth; Carole Dennie; Rob S Beanlands; Terrence D Ruddy
Journal:  J Am Coll Cardiol       Date:  2010-03-09       Impact factor: 24.094

6.  Assessment of the reproducibility of baseline and hyperemic myocardial blood flow measurements with 15O-labeled water and PET.

Authors:  P A Kaufmann; T Gnecchi-Ruscone; J T Yap; O Rimoldi; P G Camici
Journal:  J Nucl Med       Date:  1999-11       Impact factor: 10.057

7.  Heterogeneity of resting and hyperemic myocardial blood flow in healthy humans.

Authors:  P Chareonthaitawee; P A Kaufmann; O Rimoldi; P G Camici
Journal:  Cardiovasc Res       Date:  2001-04       Impact factor: 10.787

8.  Structural alterations of the coronary arterial wall are associated with myocardial flow heterogeneity in type 2 diabetes mellitus.

Authors:  Thomas H Schindler; Alvaro D Facta; John O Prior; Jerson Cadenas; Xiao-Li Zhang; Yanjie Li; James Sayre; Jonathan Goldin; Heinrich R Schelbert
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-08-15       Impact factor: 9.236

9.  Long-term prognostic value of 13N-ammonia myocardial perfusion positron emission tomography added value of coronary flow reserve.

Authors:  Bernhard A Herzog; Lars Husmann; Ines Valenta; Oliver Gaemperli; Patrick T Siegrist; Fabian M Tay; Nina Burkhard; Christophe A Wyss; Philipp A Kaufmann
Journal:  J Am Coll Cardiol       Date:  2009-07-07       Impact factor: 24.094

10.  Validation of nitrogen-13-ammonia tracer kinetic model for quantification of myocardial blood flow using PET.

Authors:  O Muzik; R S Beanlands; G D Hutchins; T J Mangner; N Nguyen; M Schwaiger
Journal:  J Nucl Med       Date:  1993-01       Impact factor: 10.057

View more
  2 in total

1.  Clinical Quantification of Myocardial Blood Flow Using PET: Joint Position Paper of the SNMMI Cardiovascular Council and the ASNC.

Authors:  Venkatesh L Murthy; Timothy M Bateman; Rob S Beanlands; Daniel S Berman; Salvador Borges-Neto; Panithaya Chareonthaitawee; Manuel D Cerqueira; Robert A deKemp; E Gordon DePuey; Vasken Dilsizian; Sharmila Dorbala; Edward P Ficaro; Ernest V Garcia; Henry Gewirtz; Gary V Heller; Howard C Lewin; Saurabh Malhotra; April Mann; Terrence D Ruddy; Thomas H Schindler; Ronald G Schwartz; Piotr J Slomka; Prem Soman; Marcelo F Di Carli; Andrew Einstein; Raymond Russell; James R Corbett
Journal:  J Nucl Cardiol       Date:  2018-02       Impact factor: 5.952

2.  Diagnostic Value of Lesion-specific Measurement of Myocardial Blood Flow Using Hybrid PET/CT.

Authors:  Sang Geon Cho; Hyeon Sik Kim; Jae Yeong Cho; Ju Han Kim; Hee Seung Bom
Journal:  J Cardiovasc Imaging       Date:  2019-12-24
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.