Literature DB >> 24002699

Influence of skull modeling approaches on EEG source localization.

Victoria Montes-Restrepo1, Pieter van Mierlo, Gregor Strobbe, Steven Staelens, Stefaan Vandenberghe, Hans Hallez.   

Abstract

Electroencephalographic source localization (ESL) relies on an accurate model representing the human head for the computation of the forward solution. In this head model, the skull is of utmost importance due to its complex geometry and low conductivity compared to the other tissues inside the head. We investigated the influence of using different skull modeling approaches on ESL. These approaches, consisting in skull conductivity and geometry modeling simplifications, make use of X-ray computed tomography (CT) and magnetic resonance (MR) images to generate seven different head models. A head model with an accurately segmented skull from CT images, including spongy and compact bone compartments as well as some air-filled cavities, was used as the reference model. EEG simulations were performed for a configuration of 32 and 128 electrodes, and for both noiseless and noisy data. The results show that skull geometry simplifications have a larger effect on ESL than those of the conductivity modeling. This suggests that accurate skull modeling is important in order to achieve reliable results for ESL that are useful in a clinical environment. We recommend the following guidelines to be taken into account for skull modeling in the generation of subject-specific head models: (i) If CT images are available, i.e., if the geometry of the skull and its different tissue types can be accurately segmented, the conductivity should be modeled as isotropic heterogeneous. The spongy bone might be segmented as an erosion of the compact bone; (ii) when only MR images are available, the skull base should be represented as accurately as possible and the conductivity can be modeled as isotropic heterogeneous, segmenting the spongy bone directly from the MR image; (iii) a large number of EEG electrodes should be used to obtain high spatial sampling, which reduces the localization errors at realistic noise levels.

Entities:  

Mesh:

Year:  2013        PMID: 24002699     DOI: 10.1007/s10548-013-0313-y

Source DB:  PubMed          Journal:  Brain Topogr        ISSN: 0896-0267            Impact factor:   3.020


  19 in total

1.  Forward and inverse effects of the complete electrode model in neonatal EEG.

Authors:  S Pursiainen; S Lew; C H Wolters
Journal:  J Neurophysiol       Date:  2016-11-16       Impact factor: 2.714

2.  Shamo: A Tool for Electromagnetic Modeling, Simulation and Sensitivity Analysis of the Head.

Authors:  Martin Grignard; Christophe Geuzaine; Christophe Phillips
Journal:  Neuroinformatics       Date:  2022-03-10

3.  Simultaneous head tissue conductivity and EEG source location estimation.

Authors:  Zeynep Akalin Acar; Can E Acar; Scott Makeig
Journal:  Neuroimage       Date:  2015-08-22       Impact factor: 6.556

4.  Visualizing simulated electrical fields from electroencephalography and transcranial electric brain stimulation: a comparative evaluation.

Authors:  Sebastian Eichelbaum; Moritz Dannhauer; Mario Hlawitschka; Dana Brooks; Thomas R Knösche; Gerik Scheuermann
Journal:  Neuroimage       Date:  2014-05-10       Impact factor: 6.556

5.  Combining EEG and MEG for the reconstruction of epileptic activity using a calibrated realistic volume conductor model.

Authors:  Ümit Aydin; Johannes Vorwerk; Philipp Küpper; Marcel Heers; Harald Kugel; Andreas Galka; Laith Hamid; Jörg Wellmer; Christoph Kellinghaus; Stefan Rampp; Carsten Hermann Wolters
Journal:  PLoS One       Date:  2014-03-26       Impact factor: 3.240

6.  The Effect of Head Model Simplification on Beamformer Source Localization.

Authors:  Frank Neugebauer; Gabriel Möddel; Stefan Rampp; Martin Burger; Carsten H Wolters
Journal:  Front Neurosci       Date:  2017-11-09       Impact factor: 4.677

7.  Combined EEG/MEG can outperform single modality EEG or MEG source reconstruction in presurgical epilepsy diagnosis.

Authors:  Ümit Aydin; Johannes Vorwerk; Matthias Dümpelmann; Philipp Küpper; Harald Kugel; Marcel Heers; Jörg Wellmer; Christoph Kellinghaus; Jens Haueisen; Stefan Rampp; Hermann Stefan; Carsten H Wolters
Journal:  PLoS One       Date:  2015-03-11       Impact factor: 3.240

8.  Electrical source imaging of interictal spikes using multiple sparse volumetric priors for presurgical epileptogenic focus localization.

Authors:  Gregor Strobbe; Evelien Carrette; José David López; Victoria Montes Restrepo; Dirk Van Roost; Alfred Meurs; Kristl Vonck; Paul Boon; Stefaan Vandenberghe; Pieter van Mierlo
Journal:  Neuroimage Clin       Date:  2016-01-20       Impact factor: 4.881

9.  The FieldTrip-SimBio pipeline for EEG forward solutions.

Authors:  Johannes Vorwerk; Robert Oostenveld; Maria Carla Piastra; Lilla Magyari; Carsten H Wolters
Journal:  Biomed Eng Online       Date:  2018-03-27       Impact factor: 2.819

10.  A novel 3D-printed head phantom with anatomically realistic geometry and continuously varying skull resistivity distribution for electrical impedance tomography.

Authors:  Jie Zhang; Bin Yang; Haoting Li; Feng Fu; Xuetao Shi; Xiuzhen Dong; Meng Dai
Journal:  Sci Rep       Date:  2017-07-04       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.