Literature DB >> 24002194

Integrated optical microfluidic biosensor using a polycarbazole photodetector for point-of-care detection of hormonal compounds.

Nuno Miguel Matos Pires, Tao Dong, Ulrik Hanke, Nils Hoivik.   

Abstract

A picogram-sensitive optical microfluidic biosensor using an integrated polycarbazole photodiode is developed. The photodetector is mainly composed of the blend heterojunction of poly [N-9'-heptadecanyl-2,7-carbazole-alt-5,5-(4',7'-di-2-thienyl-2',1',3'-benzothiadiazole)] (PCDTBT) and [6,6]-phenyl C71-butyric acid methyl ester (PC70BM) and the poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) as the hole transport layer. Analyte detection is accomplished via a chemiluminescent immunoassay performed in a poly(dimethylsiloxane)-gold-glass hybrid microchip, on which antibodies were immobilized and chemiluminescent horseradish peroxidase-luminol-peroxide reactions were generated. Enhanced sensor response to the chemiluminescent light is achieved by optimizing the thickness of PCDTBT:  PC70BM and PEDOT:PSS. Using the optimized polycarbazole photodiode for detecting the human thyroid-stimulating hormone as the model target, the integrated biosensor demonstrates an excellent linearity in the range of 0.03 to 10  ng/ml with an analytical sensitivity of 68  pg/ml. The sensor response shows high specificity and reproducibility. Hormone detection in clinical samples is further demonstrated and compared with a commercial enzyme-linked immunosorbent assay. The integrated device reported here has potential to detect other hormonal compounds or protein targets. Moreover, the presented concept enables the development of miniaturized, low-cost but highly sensitive optical microfluidic biosensors based on integrated polymer photodetectors with high potential for point-of-care diagnostics.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24002194     DOI: 10.1117/1.JBO.18.9.097001

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  10 in total

Review 1.  Biomarker detection for disease diagnosis using cost-effective microfluidic platforms.

Authors:  Sharma T Sanjay; Guanglei Fu; Maowei Dou; Feng Xu; Rutao Liu; Hao Qi; XiuJun Li
Journal:  Analyst       Date:  2015-11-07       Impact factor: 4.616

2.  Amorphous silicon p-i-n structure acting as light and temperature sensor.

Authors:  Giampiero de Cesare; Augusto Nascetti; Domenico Caputo
Journal:  Sensors (Basel)       Date:  2015-05-26       Impact factor: 3.576

3.  Design and experimental approach to the construction of a human signal-molecule-profiling database.

Authors:  Xinyan Zhao; Tao Dong
Journal:  Int J Environ Res Public Health       Date:  2013-12-09       Impact factor: 3.390

4.  Analysis on Effects of Comprehensive Nursing Care Applied in Interventional Therapy for Patients with Liver Cirrhosis and Liver Cancer.

Authors:  Yuli Gou; Jing Yi; Mei Jiang; Chunhong Cao
Journal:  Iran J Public Health       Date:  2019-03       Impact factor: 1.429

5.  Health care needs of elderly patients with lung, liver, or colon cancer in Taiwan.

Authors:  Tzu-Yin Lee; Henny Dwi Susanti; Kuo-Chen Hung; Su-Yueh Yang; Hui-Fen Fang; Jia-Ruey Tsai; Jeng-Fong Chiou; Min-Huey Chung
Journal:  BMC Palliat Care       Date:  2021-01-23       Impact factor: 3.234

6.  A microfluidic device for continuous sensing of systemic acute toxicants in drinking water.

Authors:  Xinyan Zhao; Tao Dong
Journal:  Int J Environ Res Public Health       Date:  2013-12-03       Impact factor: 3.390

7.  Microfluidic biosensor array with integrated poly(2,7-carbazole)/fullerene-based photodiodes for rapid multiplexed detection of pathogens.

Authors:  Nuno Miguel Matos Pires; Tao Dong
Journal:  Sensors (Basel)       Date:  2013-11-25       Impact factor: 3.576

8.  Design and fabrication of low-cost 1536-chamber microfluidic microarrays for mood-disorders-related serological studies.

Authors:  Xinyan Zhao; Tao Dong
Journal:  Sensors (Basel)       Date:  2013-10-28       Impact factor: 3.576

9.  Recent developments in optical detection technologies in lab-on-a-chip devices for biosensing applications.

Authors:  Nuno Miguel Matos Pires; Tao Dong; Ulrik Hanke; Nils Hoivik
Journal:  Sensors (Basel)       Date:  2014-08-21       Impact factor: 3.576

10.  The impact of intense nursing care in improving anxiety, depression, and quality of life in patients with liver cancer: A systematic review and meta-analysis.

Authors:  Qiao Zhang; Rong Wan; Changdan Liu
Journal:  Medicine (Baltimore)       Date:  2020-08-21       Impact factor: 1.817

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.