The AutoQual ultrasound elastography method for quantitative assessment of lateral strain in post-rupture Achilles tendons.

Phillip G Brown1, Joseph Alsousou, Ashley Cooper, Mark S Thompson, J Alison Noble.   

Abstract

This paper presents the AutoQual elastography method: a novel algorithm that improves the quality of 2D displacement field calculation from ultrasound radio frequency (RF) sequences of acutely ruptured Achilles tendons to determine image-lateral strain fields and has potential use for ligaments and muscles. This method uses 2D bicubic spline interpolation of the RF signal, Quality Determined Search, Automatic Search Range and Adaptive Block Size components as a novel combination that is designed to improve continuity and decrease displacement field noise, especially in areas of low signal strength. We present a simple experiment for quantitatively comparing the AutoQual method to a multiscale (MS) elastography method from ultrasound RF sequences of a 5% agar phantom for rigid body motion and known lateral strain loads with speeds up to 5mm/s. We finally present examples of four in vivo Achilles tendons in various damage states and with manual or artificially controlled passive flexion of the foot. Results show that the AutoQual method offers a substantial improvement on the MS method, achieving similar performance for rigid body tracking at all speeds, a lower normalized square error at all strains induced and a more continuous strain field at higher compression rates. AutoQual also showed a greater average normalized cross correlation for image blocks in the area of interest, a lower standard deviation of the strain field and a visually more acceptable point tracking for in vivo examples. This work demonstrates lateral ultrasound elastography which is robust to the complex passive motion of the Achilles and to various imaging artifacts associated with imaging tendon rupture. This method potentially has a wide clinical application for assessing in vivo strains in and hence mechanical function of any near skin surface tissues that are longitudinally loaded.
© 2013 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Achilles; Elastography; Lateral; Rupture; Tendon; Ultrasound

Mesh:

Year:  2013        PMID: 24001929     DOI: 10.1016/j.jbiomech.2013.07.044

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  8 in total

1.  The challenges of measuring in vivo knee collateral ligament strains using ultrasound.

Authors:  Laura C Slane; Josh A Slane; Jan D'hooge; Lennart Scheys
Journal:  J Biomech       Date:  2017-07-31       Impact factor: 2.712

2.  The use of 2D ultrasound elastography for measuring tendon motion and strain.

Authors:  Laura Chernak Slane; Darryl G Thelen
Journal:  J Biomech       Date:  2013-11-28       Impact factor: 2.712

Review 3.  The Achilles tendon: fundamental properties and mechanisms governing healing.

Authors:  Benjamin R Freedman; Joshua A Gordon; Louis J Soslowsky
Journal:  Muscles Ligaments Tendons J       Date:  2014-07-14

4.  Real-time ultrasound elastography of the Achilles tendon in patients with cerebral palsy: is there a correlation between strain ratio and biomechanical indicators?

Authors:  Mehmet Öztürk; Bahattin Sayinbatur
Journal:  J Med Ultrason (2001)       Date:  2017-06-27       Impact factor: 1.314

5.  Ultrasound strain mapping of Achilles tendon compressive strain patterns during dorsiflexion.

Authors:  Ruth L Chimenti; A Samuel Flemister; John Ketz; Mary Bucklin; Mark R Buckley; Michael S Richards
Journal:  J Biomech       Date:  2015-11-30       Impact factor: 2.712

6.  Sonoelastography shows that Achilles tendons with insertional tendinopathy are harder than asymptomatic tendons.

Authors:  Qi Zhang; Yehua Cai; Yinghui Hua; Jun Shi; Yuanyuan Wang; Yi Wang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-06-24       Impact factor: 4.342

7.  Ultrasound elasticity imaging for determining the mechanical properties of human posterior tibial tendon: a cadaveric study.

Authors:  Liang Gao; Justin S Yuan; Gregory J Heden; John A Szivek; Mihra S Taljanovic; L Daniel Latt; Russell S Witte
Journal:  IEEE Trans Biomed Eng       Date:  2015-04       Impact factor: 4.538

Review 8.  Dynamic ultrasound imaging applications to quantify musculoskeletal function.

Authors:  Siddhartha Sikdar; Qi Wei; Nelson Cortes
Journal:  Exerc Sport Sci Rev       Date:  2014-07       Impact factor: 6.230

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.