Abstract

Little is known about the microbial selectivity of UV treatment for antibiotic resistant bacteria, and the results of limited studies are conflicting. To understand the effect of UV disinfection on antibiotic resistant bacteria, both total heterotrophic bacteria and antibiotic resistant bacteria (including cephalexin-, ciprofloxacin-, erythromycin-, gentamicin-, vancomycin-, sulfadiazine-, rifampicin-, tetracycline- and chloramphenicol-resistant bacteria) were examined in secondary effluent samples from a municipal wastewater treatment plant. Bacteria resistant to both erythromycin and tetracycline were chosen as the representative of multiple-antibiotic-resistant bacteria and their characteristics after UV treatment were also investigated. UV disinfection results in effective inactivation for total heterotrophic bacteria, as well as all antibiotic resistant bacteria. After UV treatment at a fluence of 5 mJ/cm(2), the log reductions of nine types of antibiotic resistant bacteria varied from 1.0 ± 0.1 to 2.4 ± 0.1. Bacteria resistant to both erythromycin and tetracycline had a similar fluence response as did total heterotrophic bacteria. The findings suggest that UV disinfection could eliminate antibiotic resistance in wastewater treatment effluents and thus ensure public health security. Our experimental results indicated that UV disinfection led to enrichment of bacteria with resistance to sulfadiazine, vancomycin, rifampicin, tetracycline and chloramphenicol, while the proportions of cephalexin-, erythromycin-, gentamicin- and ciprofloxacin-resistant bacteria in the wastewater decreased. This reveals the microbial selectivity of UV disinfection for antibiotic resistant bacteria.
Copyright © 2013 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Antibiotic resistant bacteria; Inactivation; Microbial selectivity; Multiple-antibiotic resistance; UV disinfection

Mesh:

Substances:

Year:  2013        PMID: 24001605     DOI: 10.1016/j.watres.2013.08.012

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  4 in total

1.  Reductions of bacterial antibiotic resistance through five biological treatment processes treated municipal wastewater.

Authors:  Qing-Bin Yuan; Mei-Ting Guo; Wu-Ji Wei; Jian Yang
Journal:  Environ Sci Pollut Res Int       Date:  2016-07-06       Impact factor: 4.223

2.  Reduction of Antibiotic Resistant Bacteria During Conventional and Advanced Wastewater Treatment, and the Disseminated Loads Released to the Environment.

Authors:  Thomas Jäger; Norman Hembach; Christian Elpers; Arne Wieland; Johannes Alexander; Christian Hiller; Gerhard Krauter; Thomas Schwartz
Journal:  Front Microbiol       Date:  2018-10-30       Impact factor: 5.640

3.  Ultraviolet disinfection impacts the microbial community composition and function of treated wastewater effluent and the receiving urban river.

Authors:  Imrose Kauser; Mark Ciesielski; Rachel S Poretsky
Journal:  PeerJ       Date:  2019-08-06       Impact factor: 2.984

4.  Multidrug-Resistant Bacteria Isolated from Different Aquatic Environments in the North of Spain and South of France.

Authors:  Lara Pérez-Etayo; David González; José Leiva; Ana Isabel Vitas
Journal:  Microorganisms       Date:  2020-09-16
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.