Literature DB >> 23997746

A three-dimensional finite element analysis of finger joint stresses in the MCP joint while performing common tasks.

Kent D Butz1, Greg Merrell, Eric A Nauman.   

Abstract

The goal of this study was to develop a three-dimensional finite element model of the metacarpophalangeal (MCP) joint to characterize joint contact stresses incurred during common daily activities. The metacarpal and proximal phalanx were modeled using a COMSOL-based finite element analysis. Muscle forces determined from a static force analysis of two common activities (pen grip and carrying a weight) were applied to the simulation to characterize the surface stress distributions at the MCP joint. The finite element analysis predicted that stresses as high as 1.9 MPa, similar in magnitude to stresses experienced at the hip, may be experienced by the subchondral bone in the MCP joint. The internal structure and material properties of the phalanges were found to play a significant role in both the magnitude and distribution of stresses, but the dependence on cancellous bone modulus was not as severe as predicted by previous two dimensional models.

Keywords:  FEA; Finite element analysis; Hand strength; Joint replacement; Osteoarthritis; Rheumatoid arthritis

Year:  2012        PMID: 23997746      PMCID: PMC3418372          DOI: 10.1007/s11552-012-9430-4

Source DB:  PubMed          Journal:  Hand (N Y)        ISSN: 1558-9447


  23 in total

1.  Nonlinear behavior of trabecular bone at small strains.

Authors:  E F Morgan; O C Yeh; W C Chang; T M Keaveny
Journal:  J Biomech Eng       Date:  2001-02       Impact factor: 2.097

2.  Experimental evaluation of an elastic foundation model to predict contact pressures in knee replacements.

Authors:  Benjamin J Fregly; Yanhong Bei; Mark E Sylvester
Journal:  J Biomech       Date:  2003-11       Impact factor: 2.712

3.  Contact stresses in the glenoid component in total shoulder arthroplasty.

Authors:  W Swieszkowski; P Bednarz; P J Prendergast
Journal:  Proc Inst Mech Eng H       Date:  2003       Impact factor: 1.617

4.  Finite element analysis of the temporomandibular joint during lateral excursions of the mandible.

Authors:  A Pérez Del Palomar; M Doblaré
Journal:  J Biomech       Date:  2005-08-25       Impact factor: 2.712

5.  Using EMG data to constrain optimization procedure improves finger tendon tension estimations during static fingertip force production.

Authors:  Laurent Vigouroux; Franck Quaine; Annick Labarre-Vila; David Amarantini; François Moutet
Journal:  J Biomech       Date:  2007-05-07       Impact factor: 2.712

6.  Radiographic joint space width in the fingers of patients with rheumatoid arthritis of less than one year's duration.

Authors:  Ewan C Goligher; Jeffrey Duryea; Matthew H Liang; Frederick Wolfe; Axel Finckh
Journal:  Arthritis Rheum       Date:  2006-05

7.  Interphalangeal joint and tendon forces: normal model and biomechanical consequences of surgical reconstruction.

Authors:  N K Fowler; A C Nicol
Journal:  J Biomech       Date:  2000-09       Impact factor: 2.712

8.  In situ deformation of cartilage in cyclically loaded tibiofemoral joints by displacement-encoded MRI.

Authors:  D D Chan; C P Neu; M L Hull
Journal:  Osteoarthritis Cartilage       Date:  2009-05-07       Impact factor: 6.576

9.  Long-term assessment of Swanson implant arthroplasty in the proximal interphalangeal joint of the hand.

Authors:  Souichirou Takigawa; Steve Meletiou; Michael Sauerbier; William P Cooney
Journal:  J Hand Surg Am       Date:  2004-09       Impact factor: 2.230

10.  Resurfacing arthroplasty versus silicone arthroplasty for proximal interphalangeal joint osteoarthritis.

Authors:  Barton R Branam; Harrison G Tuttle; Peter J Stern; Linda Levin
Journal:  J Hand Surg Am       Date:  2007 Jul-Aug       Impact factor: 2.230

View more
  2 in total

1.  Biomechanical analysis of the annular ligament in Monteggia fractures using finite element models.

Authors:  Jiangwei Tan; Mingzhang Mu; Guangjun Liao; Yong Zhao; Jianmin Li
Journal:  J Orthop Surg Res       Date:  2015-03-04       Impact factor: 2.359

2.  A novel experimental design for the measurement of metacarpal bone loading and deformation and fingertip force.

Authors:  Szu-Ching Lu; Evie E Vereecke; Alexander Synek; Dieter H Pahr; Tracy L Kivell
Journal:  PeerJ       Date:  2018-09-11       Impact factor: 2.984

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.