Literature DB >> 23996980

Immunologic and tissue biocompatibility of flexible/stretchable electronics and optoelectronics.

Gayoung Park1, Hyun-Joong Chung, Kwanghee Kim, Seon Ah Lim, Jiyoung Kim, Yun-Soung Kim, Yuhao Liu, Woon-Hong Yeo, Rak-Hwan Kim, Stanley S Kim, Jong-Seon Kim, Yei Hwan Jung, Tae-Il Kim, Cassian Yee, John A Rogers, Kyung-Mi Lee.   

Abstract

Recent development of flexible/stretchable integrated electronic sensors and stimulation systems has the potential to establish an important paradigm for implantable electronic devices, where shapes and mechanical properties are matched to those of biological tissues and organs. Demonstrations of tissue and immune biocompatibility are fundamental requirements for application of such kinds of electronics for long-term use in the body. Here, a comprehensive set of experiments studies biocompatibility on four representative flexible/stretchable device platforms, selected on the basis of their versatility and relevance in clinical usage. The devices include flexible silicon field effect transistors (FETs) on polyimide and stretchable silicon FETs, InGaN light-emitting diodes (LEDs), and AlInGaPAs LEDs, each on low modulus silicone substrates. Direct cytotoxicity measured by exposure of a surrogate fibroblast line and leachable toxicity by minimum essential medium extraction testing reveal that all of these devices are non-cytotoxic. In vivo immunologic and tissue biocompatibility testing in mice indicate no local inflammation or systemic immunologic responses after four weeks of subcutaneous implantation. The results show that these new classes of flexible implantable devices are suitable for introduction into clinical studies as long-term implantable electronics.
© 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  biocompatible electronics; implantation; sensors

Mesh:

Substances:

Year:  2013        PMID: 23996980     DOI: 10.1002/adhm.201300220

Source DB:  PubMed          Journal:  Adv Healthc Mater        ISSN: 2192-2640            Impact factor:   9.933


  16 in total

1.  Ultracompliant Carbon Nanotube Direct Bladder Device.

Authors:  Dongxiao Yan; Tim M Bruns; Yuting Wu; Lauren L Zimmerman; Chris Stephan; Anne P Cameron; Euisik Yoon; John P Seymour
Journal:  Adv Healthc Mater       Date:  2019-09-25       Impact factor: 9.933

2.  Wireless, intraoral hybrid electronics for real-time quantification of sodium intake toward hypertension management.

Authors:  Yongkuk Lee; Connor Howe; Saswat Mishra; Dong Sup Lee; Musa Mahmood; Matthew Piper; Youngbin Kim; Katie Tieu; Hun-Soo Byun; James P Coffey; Mahdis Shayan; Youngjae Chun; Richard M Costanzo; Woon-Hong Yeo
Journal:  Proc Natl Acad Sci U S A       Date:  2018-05-07       Impact factor: 11.205

3.  Implanted Battery-Free Direct-Current Micro-Power Supply from in Vivo Breath Energy Harvesting.

Authors:  Jun Li; Lei Kang; Yin Long; Hao Wei; Yanhao Yu; Yizhan Wang; Carolina A Ferreira; Guang Yao; Ziyi Zhang; Corey Carlos; Lazarus German; Xiaoli Lan; Weibo Cai; Xudong Wang
Journal:  ACS Appl Mater Interfaces       Date:  2018-11-29       Impact factor: 9.229

4.  Selective Equatorial Sclera Crosslinking in the Orbit Using a Metal-Coated Polymer Waveguide.

Authors:  Sheldon J J Kwok; Sarah Forward; Christian M Wertheimer; Andreas C Liapis; Harvey H Lin; Moonseok Kim; Theo G Seiler; Reginald Birngruber; Irene E Kochevar; Theo Seiler; Seok-Hyun Yun
Journal:  Invest Ophthalmol Vis Sci       Date:  2019-06-03       Impact factor: 4.799

5.  First Food and Drug Administration Cleared Thin-Film Electrode for Intracranial Stimulation, Recording, and Monitoring of Brain Activity-Part 1: Biocompatibility Testing.

Authors:  Aura Kullmann; Debra Kridner; Steve Mertens; Mark Christianson; Dave Rosa; Camilo A Diaz-Botia
Journal:  Front Neurosci       Date:  2022-04-29       Impact factor: 5.152

6.  Highly stretchable and shape-controllable three-dimensional antenna fabricated by "Cut-Transfer-Release" method.

Authors:  Zhuocheng Yan; Taisong Pan; Guang Yao; Feiyi Liao; Zhenlong Huang; Hulin Zhang; Min Gao; Yin Zhang; Yuan Lin
Journal:  Sci Rep       Date:  2017-02-13       Impact factor: 4.379

7.  CVD-grown monolayer MoS2 in bioabsorbable electronics and biosensors.

Authors:  Xiang Chen; Yong Ju Park; Minpyo Kang; Seung-Kyun Kang; Jahyun Koo; Sachin M Shinde; Jiho Shin; Seunghyun Jeon; Gayoung Park; Ying Yan; Matthew R MacEwan; Wilson Z Ray; Kyung-Mi Lee; John A Rogers; Jong-Hyun Ahn
Journal:  Nat Commun       Date:  2018-04-27       Impact factor: 14.919

8.  Study of the Carrier-Aided Thin Film Electrode Array Design for Cochlear Insertion.

Authors:  Yuchen Xu; Chuan Luo; Fan-Gang Zeng; John C Middlebrooks; Harrison W Lin; Zheng You
Journal:  Micromachines (Basel)       Date:  2018-04-27       Impact factor: 2.891

Review 9.  Challenges in Design and Fabrication of Flexible/Stretchable Carbon- and Textile-Based Wearable Sensors for Health Monitoring: A Critical Review.

Authors:  Jae Sang Heo; Md Faruk Hossain; Insoo Kim
Journal:  Sensors (Basel)       Date:  2020-07-15       Impact factor: 3.576

10.  A Batteryless, Wireless Strain Sensor Using Resonant Frequency Modulation.

Authors:  Kyeong Jae Lee; Namsun Chou; Sohee Kim
Journal:  Sensors (Basel)       Date:  2018-11-15       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.