Literature DB >> 23993350

10-year follow-up wear analysis of first-generation highly crosslinked polyethylene in primary total hip arthroplasty.

Nimrod Snir1, Ian D Kaye1, Christopher S Klifto1, Mathew J Hamula1, Theodore S Wolfson1, Ran Schwarzkopf2, Fredrick F Jaffe1.   

Abstract

Our goal was to report a 10-year follow up of linear penetration rates for HCLPE, and to determine whether a difference exists between penetrations measured on pelvis or hip anterior-posterior radiographs. We reviewed 48 total hip arthroplasties where a first-generation HCLPE liner was used. Femoral head penetration was measured on both AP pelvis and hip radiographs. Total wear and wear rate at 10 years were 1.26 mm and 0.122 mm/y, respectively. The rate decreased significantly after the first 2-3 years, plateauing at a wear rate of 0.05 mm/y for the last 5 years. The AP hip total wear and wear rate were 1.38 mm and 0.133 mm/y respectively, while rates were 1.13 mm and 0.109 mm/y respectively for the pelvis radiographs (P<.05). We found a significant difference in measurements of linear penetration when comparing AP pelvis vs. hip radiographs with lower rates recorded using an AP pelvis.
© 2014.

Entities:  

Keywords:  10-year follow-up; first generation; highly cross linked polyethylene; total hip arthroplasty; wear analysis

Mesh:

Substances:

Year:  2013        PMID: 23993350     DOI: 10.1016/j.arth.2013.07.034

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  7 in total

1.  Is the use of thin, highly cross-linked polyethylene liners safe in total hip arthroplasty?

Authors:  Julio J Jauregui; Qais Naziri; Todd P Pierce; Randa K Elmallah; Jeffrey J Cherian; Ronald E Delanois; Michael A Mont
Journal:  Int Orthop       Date:  2015-07-02       Impact factor: 3.075

2.  Backside Wear Is Not Dependent on the Acetabular Socket Design in Crosslinked Polyethylene Liners.

Authors:  Kamal Bali; Richard W McCalden; Douglas D R Naudie; Steven J MacDonald; Matthew G Teeter
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

3.  Low failure rate at short term for 40 mm heads and second generation triple annealed HCLPE liners in hybrid hip replacements.

Authors:  Rajkumar Thangaraj; Jan Kuiper; Ralph D Perkins
Journal:  J Clin Orthop Trauma       Date:  2018-01-03

4.  Thirteen-year wear rate comparison of highly crosslinked and conventional polyethylene in total hip arthroplasty: long-term follow-up of a prospective randomized controlled trial.

Authors:  Matthew G Teeter; Xunhua Yuan; Lyndsay E Somerville; Steven J MacDonald; Richard W McCalden; Douglas D Naudie
Journal:  Can J Surg       Date:  2017-06       Impact factor: 2.089

5.  Lower prosthesis-specific 10-year revision rate with crosslinked than with non-crosslinked polyethylene in primary total knee arthroplasty.

Authors:  Richard N de Steiger; Orhun Muratoglu; Michelle Lorimer; Alana R Cuthbert; Stephen E Graves
Journal:  Acta Orthop       Date:  2015-06-28       Impact factor: 3.717

6.  High survivorship of highly cross-linked polyethylene in revision Total hip Arthroplasty: a minimum 10-year follow-up study.

Authors:  Seung-Jae Lim; Ingwon Yeo; Chan-Woo Park; Kyung-Jae Lee; Byung-Woo Min; Youn-Soo Park
Journal:  Arthroplasty       Date:  2019-12-17

7.  Long-term performance of oxidized zirconium on conventional and highly cross-linked polyethylene in total hip arthroplasty.

Authors:  Alberto V Carli; Anay R Patel; Michael B Cross; David J Mayman; Kaitlin M Carroll; Paul M Pellicci; Seth A Jerabek
Journal:  SICOT J       Date:  2020-05-07
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.