Dosimetric and radiobiological consequences of computed tomography-guided adaptive strategies for intensity modulated radiation therapy of the prostate.

Jerry J Battista1, Carol Johnson, David Turnbull, Jeff Kempe, Karl Bzdusek, Jacob Van Dyk, Glenn Bauman.   

Abstract

PURPOSE: To examine a range of scenarios for image-guided adaptive radiation therapy of prostate cancer, including different schedules for megavoltage CT imaging, patient repositioning, and dose replanning. METHODS AND MATERIALS: We simulated multifraction dose distributions with deformable registration using 35 sets of megavoltage CT scans of 13 patients. We computed cumulative dose-volume histograms, from which tumor control probabilities and normal tissue complication probabilities (NTCPs) for rectum were calculated. Five-field intensity modulated radiation therapy (IMRT) with 18-MV x-rays was planned to achieve an isocentric dose of 76 Gy to the clinical target volume (CTV). The differences between D95, tumor control probability, V70Gy, and NTCP for rectum, for accumulated versus planned dose distributions, were compared for different target volume sizes, margins, and adaptive strategies.
RESULTS: The CTV D95 for IMRT treatment plans, averaged over 13 patients, was 75.2 Gy. Using the largest CTV margins (10/7 mm), the D95 values accumulated over 35 fractions were within 2% of the planned value, regardless of the adaptive strategy used. For tighter margins (5 mm), the average D95 values dropped to approximately 73.0 Gy even with frequent repositioning, and daily replanning was necessary to correct this deficit. When personalized margins were applied to an adaptive CTV derived from the first 6 treatment fractions using the STAPLE (Simultaneous Truth and Performance Level Estimation) algorithm, target coverage could be maintained using a single replan 1 week into therapy. For all approaches, normal tissue parameters (rectum V(70Gy) and NTCP) remained within acceptable limits.
CONCLUSIONS: The frequency of adaptive interventions depends on the size of the CTV combined with target margins used during IMRT optimization. The application of adaptive target margins (<5 mm) to an adaptive CTV determined 1 week into therapy minimizes the need for subsequent dose replanning.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23978708     DOI: 10.1016/j.ijrobp.2013.07.006

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  4 in total

Review 1.  Target margins in radiotherapy of prostate cancer.

Authors:  Slav Yartsev; Glenn Bauman
Journal:  Br J Radiol       Date:  2016-07-20       Impact factor: 3.039

2.  A Simulated Dosimetric Study of Contribution to Radiotherapy Accuracy by Fractional Image Guidance Protocol of Halcyon System.

Authors:  Haiyang Wang; Yuliang Huang; Qiaoqiao Hu; Chenguang Li; Hongjia Liu; Xuejuan Wang; Weibo Li; Wenjun Ma; Yichen Pu; Yixiao Du; Hao Wu; Yibao Zhang
Journal:  Front Oncol       Date:  2021-01-25       Impact factor: 6.244

3.  Online daily assessment of dose change in head and neck radiotherapy without dose-recalculation.

Authors:  Jason R Vickress; Jerry Battista; Rob Barnett; Slav Yartsev
Journal:  J Appl Clin Med Phys       Date:  2018-08-07       Impact factor: 2.102

4.  Dosimetric benefits of daily treatment plan adaptation for prostate cancer stereotactic body radiotherapy.

Authors:  Miriam Eckl; Gustavo R Sarria; Sandra Springer; Marvin Willam; Arne M Ruder; Volker Steil; Michael Ehmann; Frederik Wenz; Jens Fleckenstein
Journal:  Radiat Oncol       Date:  2021-08-04       Impact factor: 3.481