Literature DB >> 23978267

Pharmacokinetics modeling of exogenous glucagon in type 1 diabetes mellitus patients.

Dayu Lv1, Marc D Breton, Leon S Farhy.   

Abstract

BACKGROUND: Insulin-induced hypoglycemia is as a critical barrier in the treatment of type 1 diabetes mellitus patients and may lead to unconsciousness, brain damage, or even death. Clinically, glucagon is used as a rescue drug to treat severe hypoglycemic episodes. More recently, in a bihormonal closed-loop glucose control, glucagon has been used subcutaneously along with insulin for protection against hypoglycemia. In this context, small doses of glucagon are frequently administered. The efficacy and safety of such systems, however, require precise information on the pharmacokinetics of the glucagon transport from the administrative site to the circulation, which is currently lacking. The goal of this work is to address this need by developing and validating a mathematical model of exogenous glucagon transport to the plasma.
MATERIALS AND METHODS: Eight pharmacokinetic models with various levels of complexity were fitted to nine clinical datasets. An optimal model was chosen in two consecutive steps. At Step 1, all models were screened for parameter identifiability (discarding the unidentifiable candidates). At Step 2, the remaining models are compared based on Bayesian information criterion.
RESULTS: At Step 1, two models were removed for higher parameter fractional SDs. Another three were discarded for location of their optimal parameters on the parameter search boundaries. At Step 2, an optimal model was selected based on the Bayesian information criterion. It has a simple linear structure, assuming that glucagon is injected into one compartment, from where it enters a pool for a slower release into a third, plasma compartment. In the first and third compartments, glucagon is cleared at a rate proportional to its concentration.
CONCLUSIONS: A linear kinetic model of glucagon intervention has been developed and validated. It is expected to provide guidance for glucagon delivery and the construction of preclinical simulation testing platforms.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23978267      PMCID: PMC3818836          DOI: 10.1089/dia.2013.0150

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  23 in total

1.  The conformation of glucagon: predictions and consequences.

Authors:  P Y Chou; G D Fasman
Journal:  Biochemistry       Date:  1975-06-03       Impact factor: 3.162

2.  Glucagon metabolism in man, studies on the metabolic clearance rate and the plasma acute disappearance time of glucagon in normal and diabetic subjects.

Authors:  F P Alford; S R Bloom; J D Nabarro
Journal:  J Clin Endocrinol Metab       Date:  1976-05       Impact factor: 5.958

Review 3.  Hypoglycemia risk reduction in type 1 diabetes.

Authors:  P E Cryer
Journal:  Exp Clin Endocrinol Diabetes       Date:  2001       Impact factor: 2.949

4.  A bihormonal closed-loop artificial pancreas for type 1 diabetes.

Authors:  Firas H El-Khatib; Steven J Russell; David M Nathan; Robert G Sutherlin; Edward R Damiano
Journal:  Sci Transl Med       Date:  2010-04-14       Impact factor: 17.956

Review 5.  Safe glycemic management during closed-loop treatment of type 1 diabetes: the role of glucagon, use of multiple sensors, and compensation for stress hyperglycemia.

Authors:  W Kenneth Ward; Jessica R Castle; Joseph El Youssef
Journal:  J Diabetes Sci Technol       Date:  2011-11-01

Review 6.  Hypoglycemia: still the limiting factor in the glycemic management of diabetes.

Authors:  Philip E Cryer
Journal:  Endocr Pract       Date:  2008-09       Impact factor: 3.443

7.  Glucose-responsive insulin and glucagon delivery (dual-hormone artificial pancreas) in adults with type 1 diabetes: a randomized crossover controlled trial.

Authors:  Ahmad Haidar; Laurent Legault; Maryse Dallaire; Ammar Alkhateeb; Adèle Coriati; Virginie Messier; Peiyao Cheng; Maude Millette; Benoit Boulet; Rémi Rabasa-Lhoret
Journal:  CMAJ       Date:  2013-01-28       Impact factor: 8.262

8.  Meal simulation model of the glucose-insulin system.

Authors:  Chiara Dalla Man; Robert A Rizza; Claudio Cobelli
Journal:  IEEE Trans Biomed Eng       Date:  2007-10       Impact factor: 4.538

9.  Kinetics of glucagon in man: effects of starvation.

Authors:  M Fisher; R S Sherwin; R Hendler; P Felig
Journal:  Proc Natl Acad Sci U S A       Date:  1976-05       Impact factor: 11.205

10.  Duration of type I diabetes affects glucagon and glucose responses to insulin-induced hypoglycemia.

Authors:  M Lorenzi; N Bohannon; E Tsalikian; J H Karam
Journal:  West J Med       Date:  1984-10
View more
  9 in total

1.  Incorporating an Exercise Detection, Grading, and Hormone Dosing Algorithm Into the Artificial Pancreas Using Accelerometry and Heart Rate.

Authors:  Peter G Jacobs; Navid Resalat; Joseph El Youssef; Ravi Reddy; Deborah Branigan; Nicholas Preiser; John Condon; Jessica Castle
Journal:  J Diabetes Sci Technol       Date:  2015-10-05

2.  Factors affecting the success of glucagon delivered during an automated closed-loop system in type 1 diabetes.

Authors:  P A Bakhtiani; J El Youssef; A K Duell; D L Branigan; P G Jacobs; M R Lasarev; J R Castle; W K Ward
Journal:  J Diabetes Complications       Date:  2014-09-16       Impact factor: 2.852

3.  Treating severe hypoglycemia: rapid mixing of lyophilized glucagon and diluent at point of care with the Enject GlucaPen.

Authors:  Dick Rylander
Journal:  J Diabetes Sci Technol       Date:  2014-09-02

4.  Quantification of the glycemic response to microdoses of subcutaneous glucagon at varying insulin levels.

Authors:  Joseph El Youssef; Jessica R Castle; Parkash A Bakhtiani; Ahmad Haidar; Deborah L Branigan; Matthew Breen; W Kenneth Ward
Journal:  Diabetes Care       Date:  2014-08-19       Impact factor: 19.112

5.  Design of a dual-hormone model predictive control for artificial pancreas with exercise model.

Authors:  Navid Resalat; Joseph El Youssef; Ravi Reddy; Peter G Jacobs
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2016-08

6.  Clinical Impact of Blood Glucose Monitoring Accuracy: An In-Silico Study.

Authors:  Enrique Campos-Náñez; Kurt Fortwaengler; Marc D Breton
Journal:  J Diabetes Sci Technol       Date:  2017-06-01

7.  The UVA/PADOVA Type 1 Diabetes Simulator: New Features.

Authors:  Chiara Dalla Man; Francesco Micheletto; Dayu Lv; Marc Breton; Boris Kovatchev; Claudio Cobelli
Journal:  J Diabetes Sci Technol       Date:  2014-01-01

8.  Mathematical Model of Glucagon Kinetics for the Assessment of Insulin-Mediated Glucagon Inhibition During an Oral Glucose Tolerance Test.

Authors:  Micaela Morettini; Laura Burattini; Christian Göbl; Giovanni Pacini; Bo Ahrén; Andrea Tura
Journal:  Front Endocrinol (Lausanne)       Date:  2021-03-22       Impact factor: 5.555

Review 9.  Integrating Multiple Inputs Into an Artificial Pancreas System: Narrative Literature Review.

Authors:  Chirath Hettiarachchi; Elena Daskalaki; Jane Desborough; Christopher J Nolan; David O'Neal; Hanna Suominen
Journal:  JMIR Diabetes       Date:  2022-02-24
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.