Literature DB >> 23966288

Enhanced wear and corrosion in modular tapers in total hip replacement is associated with the contact area and surface topography.

Anna Panagiotidou1, Jay Meswania, Jia Hua, Sarah Muirhead-Allwood, Alister Hart, Gordon Blunn.   

Abstract

Widespread concern exists about adverse tissue reactions after metal-on-metal (MoM) total hip replacement (THR). Concerns have also been expressed with wear and corrosion of taper junctions in THR. We report the effect of surface finish and contact area associated with a single combination of materials of modular tapers. In an in vitro test, we investigated the head/neck (CoCrMo/Ti) interface of modular THRs using commercially available heads. Wear and corrosion of taper surfaces was compared following a 10 million loading cycle. Surface parameters and profiles were measured before and after testing. Electrochemical static and dynamic corrosion tests were performed under loaded and non-loaded conditions. After the load test, the surface roughness parameters on the head taper were significantly increased where the head/neck contact area was reduced. Similarly, the surface roughness parameters on the head taper were significantly increased where rough neck tapers were used. Corrosion testing showed breaching of the passive film on the rough but not the smooth neck tapers. Thus, surface area and surface finish are important factors in wear and corrosion at modular interfaces.
© 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Entities:  

Keywords:  corrosion; metal on metal; modular taper; total hip replacement; wear

Mesh:

Substances:

Year:  2013        PMID: 23966288     DOI: 10.1002/jor.22461

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  24 in total

1.  Characterization of Femoral Head Taper Corrosion Features Using a 22-Year Retrieval Database.

Authors:  Jacob Cartner; Patrick Aldinger; Chenxi Li; David Collins
Journal:  HSS J       Date:  2016-08-12

2.  [Objectives and limits of test standards].

Authors:  C Kaddick; W Blömer
Journal:  Orthopade       Date:  2014-06       Impact factor: 1.087

3.  CORR Insights(®): Does Surface Topography Play a Role in Taper Damage in Head-neck Modular Junctions?

Authors:  Mariano Fernandez-Fairen
Journal:  Clin Orthop Relat Res       Date:  2016-07-14       Impact factor: 4.176

Review 4.  Metal-on-metal total hip arthroplasty: risk factors for pseudotumours and clinical systematic evaluation.

Authors:  Ming Han Lincoln Liow; Young-Min Kwon
Journal:  Int Orthop       Date:  2016-10-20       Impact factor: 3.075

Review 5.  Corrosion of the Head-Stem Taper Junction-Are We on the Verge of an Epidemic?: Review Article.

Authors:  Michael Morlock; Dennis Bünte; Julian Gührs; Nicholas Bishop
Journal:  HSS J       Date:  2016-09-20

6.  Do Stem Taper Microgrooves Influence Taper Corrosion in Total Hip Arthroplasty? A Matched Cohort Retrieval Study.

Authors:  Christina M Arnholt; Daniel W MacDonald; Richard J Underwood; Eric P Guyer; Clare M Rimnac; Steven M Kurtz; Michael A Mont; Gregg R Klein; Gwo-Chin Lee; Antonia F Chen; Brian R Hamlin; Harold E Cates; Arthur L Malkani; Matthew J Kraay
Journal:  J Arthroplasty       Date:  2016-11-17       Impact factor: 4.757

7.  Otto Aufranc Award: Large Heads Do Not Increase Damage at the Head-neck Taper of Metal-on-polyethylene Total Hip Arthroplasties.

Authors:  Georgios K Triantafyllopoulos; Marcella E Elpers; Jayme C Burket; Christina I Esposito; Douglas E Padgett; Timothy M Wright
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

Review 8.  Head-neck taper corrosion in hip arthroplasty.

Authors:  S Hussenbocus; D Kosuge; L B Solomon; D W Howie; R H Oskouei
Journal:  Biomed Res Int       Date:  2015-04-14       Impact factor: 3.411

9.  Femoral diameter and stem type are independent risk factors for ARMD in the large-headed ASR THR group.

Authors:  Aleksi Reito; Petra Elo; Timo Puolakka; Jorma Pajamäki; Antti Eskelinen
Journal:  BMC Musculoskelet Disord       Date:  2015-05-15       Impact factor: 2.362

10.  Quantification of the Contact Area at the Head-Stem Taper Interface of Modular Hip Prostheses.

Authors:  Florian Witt; Julian Gührs; Michael M Morlock; Nicholas E Bishop
Journal:  PLoS One       Date:  2015-08-17       Impact factor: 3.240

View more