Marginal fit of implant-supported all-ceramic zirconia frameworks.

Hanaa Hassan Zaghloul1, Jihan Farouk Younis.   

Abstract

This study evaluated the effect of fabrication techniques and cyclic loading on the vertical marginal fit of implant-supported fixed partial denture (FPD) frameworks. Thirty implant-supported 3-unit FPD frameworks were fabricated on a model system, divided into 3 equal groups (n = 10). The first group (control) was constructed from base metal alloy; the other 2 test groups were constructed from all-ceramic zirconia using a computer-aided design/computer-aided manufacturing (CAD/CAM) Cerec 3 system and a copy milling (Zirkonzahn) system. A cyclic load of 200 N was applied to each framework for up to 50,000 cycles. Linear measurements were made in micrometers of the vertical gap between the framework and the implant-supported abutment at 16 predetermined points before and after cyclic loading. The frameworks were viewed using scanning electron microscopy to inspect any fractographic features. One-way analysis of variance was performed to compare the marginal discrepancy values of the control and the 2 test groups and for each group; a t test was applied to determine whether significant changes in the fit were observed after cyclic loading (α = 0.05). The CAD/CAM group showed significantly higher marginal gap mean values (80.58 μm) than the Zirkonzahn and control groups (50.33 μm and 42.27 μm, respectively) with no significant difference. After cyclic loading, the CAD/CAM group recorded the highest marginal gap mean value (91.50 ± 4.260 μm) followed by control group (72.00 ± 2.795 μm); the Zirkonzahn group recorded the lowest marginal gap (65.37 ± 6.138 μm). Cyclic loading significantly increased the marginal gap mean values in the control group only. A marginal chip was observed in one of the CAD/CAM ceramic frameworks. Within the limitations of this study, the fabrication technique influenced the marginal fit of the implant-supported 3-unit FPD frameworks. Cyclic loading failed to change the fit of all-ceramic zirconia frameworks, whereas significant changes were found in the metal frameworks.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23964776     DOI: 10.1563/AAID-JOI-D-11-00103

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  3 in total

1.  Marginal fit of 3-unit CAD-CAM zirconia frameworks fabricated using cone beam computed tomography scans: an experimental study.

Authors:  Hüseyin Berkay Belgin; Ediz Kale; Tuncer Burak Özçelik; Burak Yilmaz
Journal:  Odontology       Date:  2021-10-19       Impact factor: 2.634

2.  Clinical Advantages and Limitations of Monolithic Zirconia Restorations Full Arch Implant Supported Reconstruction: Case Series.

Authors:  Joao Carames; Loana Tovar Suinaga; Yung Cheng Paul Yu; Alejandro Pérez; Mary Kang
Journal:  Int J Dent       Date:  2015-06-01

3.  Marginal Adaptation of Implant Prostheses Fabricated by Different Materials in Excessive Crown Height Space before and after Veneering.

Authors:  Safoura Ghodsi; Marzieh Alikhasi; Majid Sahebi; Vahideh Nazari
Journal:  Front Dent       Date:  2021-07-25
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.