Literature DB >> 2396314

Comparison of ultrafiltration devices for assessing theophylline protein binding.

J Blanchard1, S Harvey.   

Abstract

The ability of two commercially available ultrafiltration devices to assess the protein binding of theophylline was compared using human serum albumin in pH 7.4 buffer at 37 degrees C. The devices compared were the Millipore-MC filter units (Catalog number UFC3LGC00) and the Amicon Centrifree Micropartition System; both rely on centrifugal force to separate the unbound and bound molecules. The results from each device were essentially identical provided that the Millipore units were centrifuged using conditions that would not allow heat buildup to occur and thereby cause a decrease in the binding. This problem could be minimized if the Millipore units were available in a low-binding 30,000 dalton cutoff membrane instead of the 10,000 dalton membrane currently available. The use of the Millipore 30,000 dalton cutoff polysulfone membrane (UFC3TTK00) reduced the centrifugation time necessary to obtain a sufficient volume of ultrafiltrate for assay, thereby minimizing the possibility of heat generation. Furthermore, the binding of theophylline to this device was low and comparable to the binding to the Centrifree devices. Because this low degree of membrane binding may not hold for other drugs, we would suggest that a Millipore unit supplied with a low-binding, 30,000 dalton cutoff membrane could provide binding data with an efficacy comparable to that achieved with the Centrifree devices.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2396314     DOI: 10.1097/00007691-199007000-00017

Source DB:  PubMed          Journal:  Ther Drug Monit        ISSN: 0163-4356            Impact factor:   3.681


  3 in total

1.  Variability of the serum protein binding of theophylline in patients with asthma and cystic fibrosis.

Authors:  J Blanchard; S Harvey; W J Morgan
Journal:  Br J Clin Pharmacol       Date:  1992-06       Impact factor: 4.335

2.  Modulation of nonspecific binding in ultrafiltration protein binding studies.

Authors:  Kyoung-Jin Lee; Rachel Mower; Tom Hollenbeck; Jesus Castelo; Nikole Johnson; Perry Gordon; Patrick J Sinko; Kevin Holme; Yong-Hee Lee
Journal:  Pharm Res       Date:  2003-07       Impact factor: 4.200

3.  Human Serum Albumin Binding in a Vial: A Novel UV-pH Titration Method To Assist Drug Design.

Authors:  Gergő Dargó; Dávid Bajusz; Kristóf Simon; Judit Müller; György T Balogh
Journal:  J Med Chem       Date:  2020-02-11       Impact factor: 7.446

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.