Literature DB >> 23962418

Model-based iterative reconstruction for multi-detector row CT assessment of the Adamkiewicz artery.

Junko Nishida1, Kakuya Kitagawa, Motonori Nagata, Akio Yamazaki, Naoki Nagasawa, Hajime Sakuma.   

Abstract

PURPOSE: To determine if model-based iterative reconstruction (MBIR) can improve visualization of the Adamkiewicz artery on multi-detector row computed tomographic (CT) images compared with adaptive statistical iterative reconstruction (ASIR) and filtered back projection (FBP).
MATERIALS AND METHODS: This retrospective study was approved by the institutional review board, and written informed consent for the CT examination was obtained. Thirty-three patients underwent contrast material-enhanced 64-section multi-detector row CT for assessment of aortic aneurysm or dissection. Helical data were reconstructed by using FBP, ASIR, and MBIR. The signal-to-noise ratio of the aorta and contrast-to-noise ratio of the anterior spinal artery relative to the spinal cord were measured on multiplanar reformatted images. Visualization of the Adamkiewicz artery and its continuity with the intercostal or lumbar artery were evaluated by using a four-point scale. All image analyses were performed by two blinded, independent observers. The one-way analysis of variance and the Wilcoxon signed-rank test were used for statistical analysis.
RESULTS: MBIR showed significantly better signal-to-noise and contrast-to-noise ratios than did ASIR and FBP (P < .05 for all comparisons) with good interobserver agreement (intraclass correlation coefficient of 0.93 for signal-to-noise ratio and 0.75 for contrast-to-noise ratio). The visualization score of the Adamkiewicz artery was also significantly better when MBIR was used (3.4 ± 0.8 and 3.6 ± 0.7 for observers A and B, respectively) than when ASIR (2.7 ± 1.1 and 3.0 ± 1.0, respectively) or FBP (2.5 ± 1.2 and 3.1 ± 0.9, respectively) was used.
CONCLUSION: Use of the MBIR algorithm led to improved multi-detector row CT visualization of the Adamkiewicz artery when compared with the use of ASIR and FBP. © RSNA, 2013.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23962418     DOI: 10.1148/radiol.13122019

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  14 in total

1.  Identifying the Adamkiewicz artery using 3-T time-resolved magnetic resonance angiography: its role in addition to multidetector computed tomography angiography.

Authors:  Hidenobu Takagi; Hideki Ota; Yutaka Natsuaki; Yoshiaki Komori; Koki Ito; Yoshikatsu Saiki; Kei Takase
Journal:  Jpn J Radiol       Date:  2015-10-26       Impact factor: 2.374

2.  The usefulness of full-iterative reconstruction algorithm for the visualization of cystic artery on CT angiography.

Authors:  Toshihiko Hamamura; Yoshiko Hayashida; Yohei Takeshita; Koichiro Sugimoto; Issei Ueda; Koichiro Futatsuya; Shingo Kakeda; Takatoshi Aoki; Yukunori Korogi
Journal:  Jpn J Radiol       Date:  2019-04-30       Impact factor: 2.374

3.  Reduction of metal artifacts due to dental hardware in computed tomography angiography: assessment of the utility of model-based iterative reconstruction.

Authors:  Keita Kuya; Yuki Shinohara; Ayumi Kato; Makoto Sakamoto; Masamichi Kurosaki; Toshihide Ogawa
Journal:  Neuroradiology       Date:  2017-03-02       Impact factor: 2.804

4.  Filtered back projection revisited in low-kilovolt computed tomography angiography: sharp filter kernel enhances visualization of the artery of Adamkiewicz.

Authors:  Tatsuya Nishii; Akiyuki Kotoku; Yoshiro Hori; Yuji Matsuzaki; Yoshiaki Watanabe; Yoshiaki Morita; Atsushi K Kono; Hitoshi Matsuda; Tetsuya Fukuda
Journal:  Neuroradiology       Date:  2018-11-21       Impact factor: 2.804

5.  Restoration of Full Data from Sparse Data in Low-Dose Chest Digital Tomosynthesis Using Deep Convolutional Neural Networks.

Authors:  Donghoon Lee; Hee-Joung Kim
Journal:  J Digit Imaging       Date:  2019-06       Impact factor: 4.056

6.  CT angiography after carotid artery stenting: assessment of the utility of adaptive statistical iterative reconstruction and model-based iterative reconstruction.

Authors:  Keita Kuya; Yuki Shinohara; Makoto Sakamoto; Naoki Iwata; Junichi Kishimoto; Shinya Fujii; Toshio Kaminou; Takashi Watanabe; Toshihide Ogawa
Journal:  Neuroradiology       Date:  2014-08-13       Impact factor: 2.804

7.  Use of Model-Based Iterative Reconstruction (MBIR) in reduced-dose CT for routine follow-up of patients with malignant lymphoma: dose savings, image quality and phantom study.

Authors:  Edouard Hérin; François Gardavaud; Mélanie Chiaradia; Pauline Beaussart; Philippe Richard; Madeleine Cavet; Jean-François Deux; Corinne Haioun; Emmanuel Itti; Alain Rahmouni; Alain Luciani
Journal:  Eur Radiol       Date:  2015-03-08       Impact factor: 5.315

8.  Diagnostic accuracy of contemporary multidetector computed tomography (MDCT) for the detection of lumbar disc herniation.

Authors:  S Notohamiprodjo; R Stahl; M Braunagel; P M Kazmierczak; K M Thierfelder; K M Treitl; S Wirth; M Notohamiprodjo
Journal:  Eur Radiol       Date:  2016-12-17       Impact factor: 5.315

9.  Advantages of 70-kV CT Angiography for the Visualization of the Adamkiewicz Artery: Comparison with 120-kV Imaging.

Authors:  S Shimoyama; T Nishii; Y Watanabe; A K Kono; K Kagawa; S Takahashi; K Sugimura
Journal:  AJNR Am J Neuroradiol       Date:  2017-09-14       Impact factor: 3.825

10.  Ultra-high-resolution CT angiography of the artery of Adamkiewicz: a feasibility study.

Authors:  Kunihiro Yoshioka; Ryoichi Tanaka; Hidenobu Takagi; Yuta Ueyama; Kei Kikuchi; Takuya Chiba; Kazumasa Arakita; Joanne D Schuijf; Yasuo Saito
Journal:  Neuroradiology       Date:  2017-10-28       Impact factor: 2.804