CT angiography after carotid artery stenting: assessment of the utility of adaptive statistical iterative reconstruction and model-based iterative reconstruction.

Keita Kuya1, Yuki Shinohara, Makoto Sakamoto, Naoki Iwata, Junichi Kishimoto, Shinya Fujii, Toshio Kaminou, Takashi Watanabe, Toshihide Ogawa.   

Abstract

INTRODUCTION: Follow-up CT angiography (CTA) is routinely performed for post-procedure management after carotid artery stenting (CAS). However, the stent lumen tends to be underestimated because of stent artifacts on CTA reconstructed with the filtered back projection (FBP) technique. We assessed the utility of new iterative reconstruction techniques, such as adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR), for CTA after CAS in comparison with FBP.
METHODS: In a phantom study, we evaluated the differences among the three reconstruction techniques with regard to the relationship between the stent luminal diameter and the degree of underestimation of stent luminal diameter. In a clinical study, 34 patients who underwent follow-up CTA after CAS were included. We compared the stent luminal diameters among FBP, ASIR, and MBIR, and performed visual assessment of low attenuation area (LAA) in the stent lumen using a three-point scale.
RESULTS: In the phantom study, stent luminal diameter was increasingly underestimated as luminal diameter became smaller in all CTA images. Stent luminal diameter was larger with MBIR than with the other reconstruction techniques. Similarly, in the clinical study, stent luminal diameter was larger with MBIR than with the other reconstruction techniques. LAA detectability scores of MBIR were greater than or equal to those of FBP and ASIR in all cases.
CONCLUSION: MBIR improved the accuracy of assessment of stent luminal diameter and LAA detectability in the stent lumen when compared with FBP and ASIR. We conclude that MBIR is a useful reconstruction technique for CTA after CAS.

Entities:  

Mesh:

Year:  2014        PMID: 25117504     DOI: 10.1007/s00234-014-1415-2

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  24 in total

1.  Adaptive statistical iterative reconstruction technique for pulmonary CT: image quality of the cadaveric lung on standard- and reduced-dose CT.

Authors:  Masahiro Yanagawa; Osamu Honda; Shigeyuki Yoshida; Ayano Kikuyama; Atsuo Inoue; Hiromitsu Sumikawa; Mitsuhiro Koyama; Noriyuki Tomiyama
Journal:  Acad Radiol       Date:  2010-07-15       Impact factor: 3.173

2.  Diffuse lung disease: CT of the chest with adaptive statistical iterative reconstruction technique.

Authors:  Priyanka Prakash; Mannudeep K Kalra; Jeanne B Ackman; Subba R Digumarthy; Jiang Hsieh; Synho Do; Jo-Anne O Shepard; Matthew D Gilman
Journal:  Radiology       Date:  2010-07       Impact factor: 11.105

3.  Multi-detector row CT angiography in the assessment of carotid artery disease in symptomatic patients: comparison with rotational angiography and digital subtraction angiography.

Authors:  Marja Berg; Zishu Zhang; Aki Ikonen; Petri Sipola; Reetta Kälviäinen; Hannu Manninen; Ritva Vanninen
Journal:  AJNR Am J Neuroradiol       Date:  2005-05       Impact factor: 3.825

4.  Update to the AHA/ASA recommendations for the prevention of stroke in patients with stroke and transient ischemic attack.

Authors:  Robert J Adams; Greg Albers; Mark J Alberts; Oscar Benavente; Karen Furie; Larry B Goldstein; Philip Gorelick; Jonathan Halperin; Robert Harbaugh; S Claiborne Johnston; Irene Katzan; Margaret Kelly-Hayes; Edgar J Kenton; Michael Marks; Ralph L Sacco; Lee H Schwamm
Journal:  Stroke       Date:  2008-03-05       Impact factor: 7.914

5.  A three-dimensional statistical approach to improved image quality for multislice helical CT.

Authors:  Jean-Baptiste Thibault; Ken D Sauer; Charles A Bouman; Jiang Hsieh
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

6.  Comparison of carotid stents: an in-vitro experiment focusing on stent design.

Authors:  Stefan Müller-Hülsbeck; Philipp J Schäfer; Nikolas Charalambous; Silvio R Schaffner; Martin Heller; Thomas Jahnke
Journal:  J Endovasc Ther       Date:  2009-04       Impact factor: 3.487

7.  Vascular diameter measurement in CT angiography: comparison of model-based iterative reconstruction and standard filtered back projection algorithms in vitro.

Authors:  Shigeru Suzuki; Haruhiko Machida; Isao Tanaka; Eiko Ueno
Journal:  AJR Am J Roentgenol       Date:  2013-03       Impact factor: 3.959

8.  Stroke after carotid stenting and endarterectomy in the Carotid Revascularization Endarterectomy versus Stenting Trial (CREST).

Authors:  Michael D Hill; William Brooks; Ariane Mackey; Wayne M Clark; James F Meschia; William F Morrish; J P Mohr; J David Rhodes; Jeffrey J Popma; Brajesh K Lal; Mary E Longbottom; Jenifer H Voeks; George Howard; Thomas G Brott
Journal:  Circulation       Date:  2012-11-16       Impact factor: 29.690

9.  Risk of stroke in the distribution of an asymptomatic carotid artery. The European Carotid Surgery Trialists Collaborative Group.

Authors: 
Journal:  Lancet       Date:  1995-01-28       Impact factor: 79.321

10.  Restenosis after carotid artery stenting and endarterectomy: a secondary analysis of CREST, a randomised controlled trial.

Authors:  Brajesh K Lal; Kirk W Beach; Gary S Roubin; Helmi L Lutsep; Wesley S Moore; Mahmoud B Malas; David Chiu; Nicole R Gonzales; J Lee Burke; Michael Rinaldi; James R Elmore; Fred A Weaver; Craig R Narins; Malcolm Foster; Kim J Hodgson; Alexander D Shepard; James F Meschia; Robert O Bergelin; Jenifer H Voeks; George Howard; Thomas G Brott
Journal:  Lancet Neurol       Date:  2012-08-02       Impact factor: 44.182

View more
  1 in total

1.  Reduction of metal artifacts due to dental hardware in computed tomography angiography: assessment of the utility of model-based iterative reconstruction.

Authors:  Keita Kuya; Yuki Shinohara; Ayumi Kato; Makoto Sakamoto; Masamichi Kurosaki; Toshihide Ogawa
Journal:  Neuroradiology       Date:  2017-03-02       Impact factor: 2.804