Literature DB >> 23960484

Bi-axial flexural strength of dual-polymerizing agents cemented to human dentin after photo-activation with different light-curing systems.

Nadia Malek A Taher1.   

Abstract

OBJECTIVES: This study aimed to assess the bi-axial flexural strength of two dual-polymerizing resin luting agents cemented to human dentin when photo-activated with different light-curing units.
MATERIALS AND METHODS: Two dual-cured resin cements: choice (CH) and Variolink II (VL) were tested. Hybrid composite resin (Z-250) discs (12 × 1.5 mm) were fabricated. Three types of light-curing units were used halogen-curing unit (QTH), light-emitting diode (LED) and plasma arc (PAC). Sixty dentin discs of 0.5 mm thickness were prepared from extracted human teeth. A circular mold (2.5 mm in height and 12 mm diameter) was utilized to create supporting structure for dentin, resin cement complex. The resin luting cement (0.5 mm) was placed on the previously prepared dentin discs and covered with the prefabricated composite discs. Photo-activation of cements was performed for 40 s with QTH and LED units and for 3 s with PAC. The specimens were divided into 12 groups (20 specimens for each light source). Six groups were kept in distilled water for 24 h and the rest were stored for 6 weeks. Bi-axial flexural strength was determined using Instron machine. The data was analyzed using two-way ANOVA and Tukey test for comparison.
RESULTS: The findings indicated that the bi-axial flexural strength values for both cements CH and VL were higher for 24 h over 6 weeks but not statistically significant when cured with QTH. Meanwhile, when LED light was used for photo-activation the cements, the flexural strength values reported were statistically higher of 24 h over 6 weeks storage at P = 0.4(E-6) However, PAC light did not record any statistically significant difference between two duration for the CH cement although when used for polymerization of VL the reported value for 6 weeks were statistically significantly higher value than 24 h duration at P = 0.002.
CONCLUSION: When high immediate flexural strength is preferred in clinical situation photo-activation the cements with LED reported the greatest value.

Entities:  

Keywords:  Bi-axial flexural strength; Dual curing cement; Light-curing unit; Resin cement

Year:  2010        PMID: 23960484      PMCID: PMC3723075          DOI: 10.1016/j.sdentj.2010.04.002

Source DB:  PubMed          Journal:  Saudi Dent J        ISSN: 1013-9052


  25 in total

1.  Effect of resin matrix ratio, storage medium, and time upon the physical properties of a radiopaque dental composite.

Authors:  C S Deepa; V K Krishnan
Journal:  J Biomater Appl       Date:  2000-01       Impact factor: 2.646

2.  Optical power outputs, spectra and dental composite depths of cure, obtained with blue light emitting diode (LED) and halogen light curing units (LCUs).

Authors:  R W Mills; A Uhl; K D Jandt
Journal:  Br Dent J       Date:  2002-10-26       Impact factor: 1.626

3.  The reliability in flexural strength testing of a novel dental composite.

Authors:  William M Palin; Garry J P Fleming; F J Trevor Burke; Peter M Marquis; Ros C Randall
Journal:  J Dent       Date:  2003-11       Impact factor: 4.379

4.  Retention of posts with resin, glass ionomer and hybrid cements.

Authors:  R M Love; D G Purton
Journal:  J Dent       Date:  1998-09       Impact factor: 4.379

5.  Effect of light exposure on fracture toughness and flexural strength of light-cured composites.

Authors:  M Miyazaki; Y Oshida; B K Moore; H Onose
Journal:  Dent Mater       Date:  1996-11       Impact factor: 5.304

6.  Influence of light intensity on two restorative systems.

Authors:  G L Unterbrink; R Muessner
Journal:  J Dent       Date:  1995-06       Impact factor: 4.379

7.  Dual-cure luting composites: Part I: Filler particle distribution.

Authors:  S Inokoshi; G Willems; B Van Meerbeek; P Lambrechts; M Braem; G Vanherle
Journal:  J Oral Rehabil       Date:  1993-03       Impact factor: 3.837

8.  In vitro aging of dental composites in water--effect of degree of conversion, filler volume, and filler/matrix coupling.

Authors:  J L Ferracane; H X Berge; J R Condon
Journal:  J Biomed Mater Res       Date:  1998-12-05

9.  The effect of different light-curing methods on temperature changes of dual polymerizing agents cemented to human dentin.

Authors:  Nadia Malek Taher; Yousra Al-Khairallah; Sheikha Hamed Al-Aujan; Maha Ad'dahash
Journal:  J Contemp Dent Pract       Date:  2008-02-01

10.  Microtensile bond strength of dual-polymerizing cementing systems to dentin using different polymerizing modes.

Authors:  Cesar A G Arrais; Marcelo Giannini; Frederick A Rueggeberg; David H Pashley
Journal:  J Prosthet Dent       Date:  2007-02       Impact factor: 3.426

View more