Literature DB >> 23959743

Early results of a novel technique for ring-reinforced aortic valve and root restoration.

Domenico Mazzitelli1, Christian Nöbauer, J Scott Rankin, Catalin C Badiu, Magdalena Dorfmeister, Philip S Crooke, Anke Wagner, Christian Schreiber, Rüdiger Lange.   

Abstract

OBJECTIVES: Surgery for aortic root aneurysm without valve stenosis is increasingly being transformed from the Bentall procedure to valve-sparing aortic root remodelling or reimplantation. In this report, a new repair option is explored, with full functional 'restoration' of the aortic root complex using a geometric annuloplasty ring, leaflet repair, and sinus/ascending aortic replacement with a Valsalva graft.
METHODS: The geometric annuloplasty ring restores elliptical annular shape and size in patients with tri-leaflet aortic insufficiency (AI). The ring mounts the three valve commissures on 10° outwardly flaring posts, and facilitates required leaflet procedures. In clinical application, the device has been effective in achieving stable AI reduction with low valve gradients. In this report, 6 patients with aortic root aneurysms and moderate/severe AI were managed with valve repair using the annuloplasty device and leaflet reconstruction, and then concomitant sinus and ascending aortic graft replacement with coronary implantation.
RESULTS: In the 6 initial root aneurysm patients, there were no in-hospital mortalities, procedural conversions, or valve-related complications. Preoperative AI grade was 2-4 and fell to 0-1 postoperatively. Post-repair mean systolic gradients ranged from 7 to 12 mmHg, and all patients had stable intermediate-term valve function.
CONCLUSIONS: Aortic root restoration using a geometric annuloplasty ring and Valsalva graft may be the most physiological method of aortic valve repair and root replacement. Even with severe leaflet derangements, valve sparing can be achieved with good competence and potentially stable long-term results. This technique could assist in extending valve sparing into most categories of aortic root disease. CLINICAL TRIALS: Patients were managed as part of a Phase I (ClinicalTrials.gov Identifier: NCT01400841), supported by BioStable Science and Engineering (BSE), Austin, TX, USA; www.biostable-s-e.com.

Entities:  

Keywords:  Annuloplasty ring; Aortic aneurysm; Aortic root restoration; Aortic valve; Aortic valve repair; Ring annuloplasty; Valve repair; Valve sparing

Mesh:

Year:  2013        PMID: 23959743     DOI: 10.1093/ejcts/ezt407

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  4 in total

1.  Aortic valve repair with a newly approved geometric annuloplasty ring in patients undergoing proximal aortic repair: early results from a single-centre experience.

Authors:  Oliver K Jawitz; Vignesh Raman; Jatin Anand; Muath Bishawi; Soraya L Voigt; Julie Doberne; Andrew M Vekstein; E Hope Weissler; Joseph W Turek; G Chad Hughes
Journal:  Eur J Cardiothorac Surg       Date:  2020-06-01       Impact factor: 4.191

2.  Valve-sparing reimplantation technique for treatment of neoaortic root dilatation late after the arterial switch operation: raising the bar.

Authors:  Markus Liebrich; Michael Scheid; Frank Uhlemann; Wolfgang B Hemmer
Journal:  Thorac Cardiovasc Surg Rep       Date:  2014-09-04

3.  First uses of HAART 300 rings for aortic valve repair in Poland - 4 case studies.

Authors:  Jacek H Juściński; Andrzej Koprowski; Magdalena Kołaczkowska; Maciej M Kowalik; Jan A Rogowski; James S Rankin
Journal:  Kardiochir Torakochirurgia Pol       Date:  2018-03-28

4.  Bicuspid aortic valve repair using geometric ring annuloplasty: A first-in-humans pilot trial.

Authors:  J Scott Rankin; Domenico Mazzitelli; Theodor J M Fischlein; Yeong-Hoon Choi; Diana Aicher; Lawrence M Wei; Vinay Badhwar
Journal:  JTCVS Tech       Date:  2020-01-23
  4 in total