Literature DB >> 23958234

Research synthesis of recommended acetabular cup orientations for total hip arthroplasty.

Claire L Harrison1, Avril I Thomson2, Steven Cutts3, Philip J Rowe1, Philip E Riches1.   

Abstract

Total hip arthroplasty (THA) is regarded as one of the most successful surgical procedures of modern times yet continues to be associated with a small but significant complication rate. Many early failures may be associated with poor component positioning with, in particular, acetabular component orientation dependent on the subjective judgement of the surgeon. In this paper, we compare the manufacturers' instructions on acetabular cup orientation with the literature-based recommended safety zones and surgical technique, by transforming them onto a single, clinically-relevant framework in which the different reference systems, safety guidelines and current instrumentation surgical techniques can be evaluated. The observed limited consensus between results reflects ongoing uncertainty regarding the optimum acetabular component positioning. As malpositioning of the acetabular cup increases the risk of revision surgery, any ambiguity over the correct position can have a causal effect. Our analysis highlights the need for a surgical reference system which can be used to describe the position of the acetabular cup intra-operatively.
© 2013 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  acetabular cup; correct orientation; malpositioning; total hip arthroplasty

Mesh:

Year:  2013        PMID: 23958234     DOI: 10.1016/j.arth.2013.06.026

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  14 in total

1.  What Safe Zone? The Vast Majority of Dislocated THAs Are Within the Lewinnek Safe Zone for Acetabular Component Position.

Authors:  Matthew P Abdel; Philipp von Roth; Matthew T Jennings; Arlen D Hanssen; Mark W Pagnano
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

2.  CORR Insights®: What Is the Survivorship of Revision Surgery Performed for the Chronically Dislocated THA?

Authors:  Denis Nam
Journal:  Clin Orthop Relat Res       Date:  2019-02       Impact factor: 4.176

3.  Accuracy of measuring acetabular cup position after total hip arthroplasty: comparison between a radiographic planning software and three-dimensional computed tomography.

Authors:  Vahdettin Bayraktar; Markus Weber; Frederik von Kunow; Florian Zeman; Benjamin Craiovan; Tobias Renkawitz; Joachim Grifka; Michael Woerner
Journal:  Int Orthop       Date:  2016-06-08       Impact factor: 3.075

4.  A retrospective study on the relationship between altered native acetabular angle and vertical implant malpositioning.

Authors:  Jorge Rojas; Maria Bautista; Guillermo Bonilla; Omar Amado; Elina Huerfano; Daniel Monsalvo; Adolfo Llinás; José Navas
Journal:  Int Orthop       Date:  2017-08-07       Impact factor: 3.075

5.  Low dislocation rates with the use of patient specific "Safe zones" in total hip arthroplasty.

Authors:  Abhinav K Sharma; Zlatan Cizmic; Douglas A Dennis; Stefan W Kreuzer; Michael A Miranda; Jonathan M Vigdorchik
Journal:  J Orthop       Date:  2021-08-21

6.  Compared learning curves of the direct anterior and anterolateral approach for minimally invasive hip replacement.

Authors:  Johannes C Reichert; Georgi I Wassilew; Eberhard von Rottkay; Ulrich Noeth
Journal:  Orthop Rev (Pavia)       Date:  2022-08-25

7.  Total Hip Arthroplasty with Robotic Arm Assistance for Precise Cup Positioning: A Case-Control Study.

Authors:  Dong-Hui Guo; Xiao-Ming Li; Shi-Qiang Ma; Yun-Chao Zhao; Chao Qi; Yuan Xue
Journal:  Orthop Surg       Date:  2022-06-14       Impact factor: 2.279

8.  Possible Vascular Injury Due to Screw Eccentricity in Minimally Invasive Total Hip Arthroplasty.

Authors:  Nishant Kumar Singh; Sanjay Kumar Rai; Amit Rastogi
Journal:  Indian J Orthop       Date:  2017 Jul-Aug       Impact factor: 1.251

9.  Well-Placed Acetabular Component Oriented Outside the Safe Zone During Weight-Bearing Daily Activities.

Authors:  Nan Zheng; Xiangjun Hu; Dimitris Dimitriou; Kerong Dai; Tao Guo; Tsung-Yuan Tsai
Journal:  Front Bioeng Biotechnol       Date:  2021-06-10

10.  Visual intraoperative estimation of cup and stem position is not reliable in minimally invasive hip arthroplasty.

Authors:  Michael Woerner; Ernst Sendtner; Robert Springorum; Benjamin Craiovan; Michael Worlicek; Tobias Renkawitz; Joachim Grifka; Markus Weber
Journal:  Acta Orthop       Date:  2016-02-05       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.