Literature DB >> 2395025

Scatter and attenuation correction in SPECT using density maps and Monte Carlo simulated scatter functions.

M Ljungberg1, S E Strand.   

Abstract

A new scatter and attenuation correction method is presented in which Monte Carlo simulated scatter line-spread functions for different depth and lateral positions are used. A reconstructed emission image is used as an estimate of the source distribution in order to calculate the scatter contribution in the projection data. The scatter contribution is then subtracted from the original projection prior to attenuation correction. The attenuation correction method uses density maps for the attenuation correction of projection data. Simulation studies have been done with a clinically realistic source distribution in cylindrical, homogeneous water phantoms of different sizes and with photon energies corresponding to 201T1, 99mTc, and 111In. The results show excellent quantitative results with an accuracy within +/- 10% for most of the source positions and phantom sizes. It has also been shown that the variation in the event distribution within the source region in the images has been significantly decreased and that an enhancement in the contrast has been achieved.

Entities:  

Mesh:

Year:  1990        PMID: 2395025

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  16 in total

Review 1.  Digital image processing for clinicians, part III: SPECT reconstruction.

Authors:  Christopher L Hansen
Journal:  J Nucl Cardiol       Date:  2002 Sep-Oct       Impact factor: 5.952

2.  Quantitative single photon emission tomography: verification for sources in an elliptical water phantom.

Authors:  M H Ljungberg; M A King; S E Strand
Journal:  Eur J Nucl Med       Date:  1992

Review 3.  Scatter modelling and compensation in emission tomography.

Authors:  Habib Zaidi; Kenneth F Koral
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-03-31       Impact factor: 9.236

Review 4.  Quantitative analysis in single photon emission tomography (SPET).

Authors:  K A Blokland; H H Reiber; E K Pauwels
Journal:  Eur J Nucl Med       Date:  1992

5.  Development of a practical image-based scatter correction method for brain perfusion SPECT: comparison with the TEW method.

Authors:  Miho Shidahara; Hiroshi Watabe; Kyeong Min Kim; Takashi Kato; Shoji Kawatsu; Rikio Kato; Kumiko Yoshimura; Hidehiro Iida; Kengo Ito
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-05-28       Impact factor: 9.236

Review 6.  Technological development and advances in single-photon emission computed tomography/computed tomography.

Authors:  Youngho Seo; Carina Mari; Bruce H Hasegawa
Journal:  Semin Nucl Med       Date:  2008-05       Impact factor: 4.446

Review 7.  Quantitative assessment of regional myocardial blood flow with thallium-201 and SPECT.

Authors:  H Iida; S Eberl
Journal:  J Nucl Cardiol       Date:  1998 May-Jun       Impact factor: 5.952

8.  Transmission-based scatter correction of 180 degrees myocardial single-photon emission tomographic studies.

Authors:  B F Hutton; A Osiecki; S R Meikle
Journal:  Eur J Nucl Med       Date:  1996-10

9.  Attenuation correction of (111)In planar images by use of dual energy, fundamental study by Monte Carlo simulation.

Authors:  Seiji Shirakawa; Masanori Tadokoro; Hiroshi Hashimoto; Tomoya Ushiroda; Hiroshi Toyama
Journal:  Radiol Phys Technol       Date:  2014-08-23

Review 10.  Three-dimensional imaging-based radiobiological dosimetry.

Authors:  George Sgouros; Eric Frey; Richard Wahl; Bin He; Andrew Prideaux; Robert Hobbs
Journal:  Semin Nucl Med       Date:  2008-09       Impact factor: 4.446

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.