Literature DB >> 23948123

What happens to serum metal ion levels after a metal-on-metal bearing is removed?

Scott T Ball1, Dustyn Severns, Michael Linn, R Scott Meyer, F Craig Swenson.   

Abstract

Serum cobalt (Co) and chromium (Cr) levels are commonly used to screen for excessive wear of metal-on-metal hip replacements. However, it is unknown how rapidly these should decline after revision. 25 patients with average Co and Cr ion levels of 56.3 μg/L and 20.5 μg/L were followed with serial ion level testing post-revision. Over the first 6 weeks post-revision, the rate of decline for Co and Cr was approximately 2% per day and this slowed to approximately 1% decline per day over the ensuing 6 weeks. This translated to a decline of approximately 80% from the starting value after 6 weeks and a decline of approximately 90% after 12 weeks post-revision. The rate of decline for both Co and Cr was significantly faster during the first 6 weeks (P<0.001). In patients with ultra-high Cr levels>20 μg/L, the rate of Cr decline is less predictable and may be protracted leading to persistent elevation above 5 μg/L for one year or more post-revision in some cases.
© 2013 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  chromium; cobalt; metal ions; metal-on-metal; revision total hip

Mesh:

Substances:

Year:  2013        PMID: 23948123     DOI: 10.1016/j.arth.2013.06.040

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  6 in total

Review 1.  The surgical options and clinical evidence for treatment of wear or corrosion occurring with THA or TKA.

Authors:  Charles A Engh; Henry Ho; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

Review 2.  Revision total hip arthroplasty for metal-on-metal failure.

Authors:  Justin S Chang; Fares S Haddad
Journal:  J Clin Orthop Trauma       Date:  2019-10-04

3.  Revision of Metal-on-metal Hip Prostheses Results in Marked Reduction of Blood Cobalt and Chromium Ion Concentrations.

Authors:  Olli Lainiala; Aleksi Reito; Petra Elo; Jorma Pajamäki; Timo Puolakka; Antti Eskelinen
Journal:  Clin Orthop Relat Res       Date:  2015-01-27       Impact factor: 4.176

4.  Outcomes after revision of metal on metal hip resurfacing to total arthroplasty using the direct anterior approach.

Authors:  Victoire Bouveau; Thomas-Xavier Haen; Joel Poupon; Christophe Nich
Journal:  Int Orthop       Date:  2018-03-08       Impact factor: 3.075

Review 5.  Management of metal-on-metal hip implant patients: Who, when and how to revise?

Authors:  Reshid Berber; John A Skinner; Alister J Hart
Journal:  World J Orthop       Date:  2016-05-18

6.  Nickel contamination after minimally-invasive repair of pectus excavatum persists after bar removal.

Authors:  Caroline Fortmann; Thomas Goeen; Norman Zinne; Soeren Wiesner; Benno M Ure; Claus Petersen; Joachim F Kuebler
Journal:  PLoS One       Date:  2022-10-10       Impact factor: 3.752

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.