Literature DB >> 23947655

Multi-institutional comparison of whole slide digital imaging and optical microscopy for interpretation of hematoxylin-eosin-stained breast tissue sections.

Savitri Krishnamurthy1, Kurt Mathews, Steven McClure, Melissa Murray, Michael Gilcrease, Constance Albarracin, John Spinosa, Bernard Chang, James Ho, John Holt, Arthur Cohen, Dilip Giri, Karuna Garg, Roland L Bassett, Kevin Liang.   

Abstract

CONTEXT: Whole slide imaging (WSI) is now used for educational purposes, for consultation, and for archiving and quantitation of immunostains. However, it is not routinely used for the primary diagnosis of hematoxylin-eosin-stained tissue sections.
OBJECTIVE: To compare WSI using the Aperio digital pathology system (Aperio Technologies, Inc, Vista, California) with optical microscopy (OM) for the interpretation of hematoxylin-eosin-stained tissue sections of breast lesions.
DESIGN: The study was conducted at 3 clinical sites; 3 breast pathologists interpreted 150 hematoxylin-eosin-stained slides at each site, 3 times each by WSI and 3 times each by OM. For WSI, slides were scanned using an Aperio ScanScope and interpreted on a computer monitor using Aperio ImageScope software and Aperio Spectrum data management software. Pathologic interpretations were recorded using the College of American Pathologists breast checklist. WSI diagnoses were compared with OM diagnoses for accuracy, precision (interpathologist variation), and reproducibility (intrapathologist variation). Results were considered accurate only if the interpretation matched exactly between WSI and OM. The proportion of accurate results reported by each pathologist was expressed as a percentage for the comparison of the 2 platforms.
RESULTS: The accuracy of WSI for classifying lesions as not carcinoma or as noninvasive (ductal or lobular) or invasive (ductal, lobular, or other) carcinoma was 90.5%. The accuracy of OM was 92.1%. The precision and reproducibility of WSI and OM were determined on the basis of pairwise comparisons (3 comparisons for each slide, resulting in 36 possible comparisons). The overall precision of WSI was 90.5% in comparison with 92.1% for OM; reproducibility of WSI was 91.6% in comparison with 94.5% for OM, respectively.
CONCLUSIONS: In this study, we demonstrated that WSI and OM have similar accuracy, precision, and reproducibility for interpreting hematoxylin-eosin-stained breast tissue sections. Further clinical studies using routine surgical pathology specimens would be useful to confirm these findings and facilitate the incorporation of WSI into diagnostic practice.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23947655     DOI: 10.5858/arpa.2012-0437-OA

Source DB:  PubMed          Journal:  Arch Pathol Lab Med        ISSN: 0003-9985            Impact factor:   5.534


  16 in total

1.  Multireader multicase reader studies with binary agreement data: simulation, analysis, validation, and sizing.

Authors:  Weijie Chen; Adam Wunderlich; Nicholas Petrick; Brandon D Gallas
Journal:  J Med Imaging (Bellingham)       Date:  2014-12-04

2.  Validation of digital microscopy in the histopathological diagnoses of oral diseases.

Authors:  Anna Luíza Damaceno Araújo; Gleyson Kleber Amaral-Silva; Felipe Paiva Fonseca; Natália Rangel Palmier; Marcio Ajudarte Lopes; Paul M Speight; Oslei Paes de Almeida; Pablo Agustin Vargas; Alan Roger Santos-Silva
Journal:  Virchows Arch       Date:  2018-06-01       Impact factor: 4.064

3.  The performance of digital microscopy for primary diagnosis in human pathology: a systematic review.

Authors:  Anna Luíza Damaceno Araújo; Lady Paola Aristizábal Arboleda; Natalia Rangel Palmier; Jéssica Montenegro Fonsêca; Mariana de Pauli Paglioni; Wagner Gomes-Silva; Ana Carolina Prado Ribeiro; Thaís Bianca Brandão; Luciana Estevam Simonato; Paul M Speight; Felipe Paiva Fonseca; Marcio Ajudarte Lopes; Oslei Paes de Almeida; Pablo Agustin Vargas; Cristhian Camilo Madrid Troconis; Alan Roger Santos-Silva
Journal:  Virchows Arch       Date:  2019-01-26       Impact factor: 4.064

Review 4.  Integrating digital pathology into clinical practice.

Authors:  Matthew G Hanna; Orly Ardon; Victor E Reuter; Sahussapont Joseph Sirintrapun; Christine England; David S Klimstra; Meera R Hameed
Journal:  Mod Pathol       Date:  2021-10-01       Impact factor: 7.842

5.  Evaluation of cytokeratin-19 in breast cancer tissue samples: a comparison of automatic and manual evaluations of scanned tissue microarray cylinders.

Authors:  Cristina Callau; Marylène Lejeune; Anna Korzynska; Marcial García; Gloria Bueno; Ramon Bosch; Joaquín Jaén; Guifré Orero; Teresa Salvadó; Carlos López
Journal:  Biomed Eng Online       Date:  2015-08-13       Impact factor: 2.819

6.  Digital slide viewing for primary reporting in gastrointestinal pathology: a validation study.

Authors:  Maurice B Loughrey; Paul J Kelly; Oisin P Houghton; Helen G Coleman; Joseph P Houghton; Anne Carson; Manuel Salto-Tellez; Peter W Hamilton
Journal:  Virchows Arch       Date:  2015-05-16       Impact factor: 4.064

7.  The relationship between histologic grades of invasive carcinoma of breast ducts and mast cell infiltration.

Authors:  Ashraf Fakhrjou; Mohammad Naghavi-Behzad; Vahid Montazeri; Farid Karkon-Shayan; Leila Norouzi-Panahi; Reza Piri
Journal:  South Asian J Cancer       Date:  2016 Jan-Mar

Review 8.  "Slide less pathology": Fairy tale or reality?

Authors:  M Indu; R Rathy; M P Binu
Journal:  J Oral Maxillofac Pathol       Date:  2016 May-Aug

9.  Overexpression of cofilin correlates with poor survival in breast cancer: A tissue microarray analysis.

Authors:  Yusufu Maimaiti; Jie Tan; Zeming Liu; Yawen Guo; Yu Yan; Xiu Nie; Bangxing Huang; Jing Zhou; Tao Huang
Journal:  Oncol Lett       Date:  2017-06-19       Impact factor: 2.967

10.  Whole Slide Imaging Versus Microscopy for Primary Diagnosis in Surgical Pathology: A Multicenter Blinded Randomized Noninferiority Study of 1992 Cases (Pivotal Study).

Authors:  Sanjay Mukhopadhyay; Michael D Feldman; Esther Abels; Raheela Ashfaq; Senda Beltaifa; Nicolas G Cacciabeve; Helen P Cathro; Liang Cheng; Kumarasen Cooper; Glenn E Dickey; Ryan M Gill; Robert P Heaton; René Kerstens; Guy M Lindberg; Reenu K Malhotra; James W Mandell; Ellen D Manlucu; Anne M Mills; Stacey E Mills; Christopher A Moskaluk; Mischa Nelis; Deepa T Patil; Christopher G Przybycin; Jordan P Reynolds; Brian P Rubin; Mohammad H Saboorian; Mauricio Salicru; Mark A Samols; Charles D Sturgis; Kevin O Turner; Mark R Wick; Ji Y Yoon; Po Zhao; Clive R Taylor
Journal:  Am J Surg Pathol       Date:  2018-01       Impact factor: 6.394

View more