Literature DB >> 23942975

Impact of soft contact lens edge design and midperipheral lens shape on the epithelium and its indentation with lens mobility.

James S Wolffsohn1, Thomas Drew, Sandeep Dhallu, Amy Sheppard, Greg J Hofmann, Mark Prince.   

Abstract

PURPOSE: To evaluate the influence of soft contact lens midperipheral shape profile and edge design on the apparent epithelial thickness and indentation of the ocular surface with lens movement.
METHODS: Four soft contact lens designs comprising of two different plano midperipheral shape profiles and two edge designs (chiseled and knife edge) of silicone-hydrogel material were examined in 26 subjects aged 24.7 ± 4.6 years, each worn bilaterally in randomized order. Lens movement was imaged enface on insertion, at 2 and 4 hours with a high-speed, high-resolution camera simultaneous to the cross-section of the edge of the contact lens interaction with the ocular surface captured using optical coherence tomography (OCT) nasally, temporally, and inferiorly. Optical imaging distortions were individually corrected for by imaging the apparent distortion of a glass slide surface by the removed lens.
RESULTS: Apparent epithelial thickness varied with edge position (P < 0.001). When distortion was corrected for, epithelial indentation decreased with time after insertion (P = 0.010), changed after a blink (P < 0.001), and varied with position on the lens edge (P < 0.001), with the latter being affected by midperipheral lens shape profile and edge design. Horizontal and vertical lens movement did not change with time postinsertion. Vertical motion was affected by midperipheral lens shape profile (P < 0.001) and edge design (P < 0.001). Lens movement was associated with physiologic epithelium thickness for lens midperipheral shape profile and edge designs.
CONCLUSIONS: Dynamic OCT coupled with high-resolution video demonstrated that soft contact lens movement and image-corrected ocular surface indentation were influenced by both lens edge design and midperipheral lens shape profiles.

Entities:  

Keywords:  contact lenses; edge design; epithelial indentation; epithelial thickness

Mesh:

Year:  2013        PMID: 23942975     DOI: 10.1167/iovs.13-12425

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  4 in total

1.  Optical Assessment of Soft Contact Lens Edge-Thickness.

Authors:  Patrice Tankam; Jungeun Won; Cristina Canavesi; Ian Cox; Jannick P Rolland
Journal:  Optom Vis Sci       Date:  2016-08       Impact factor: 1.973

2.  Optical coherence tomography to evaluate the interaction of different edge designs of four different silicone hydrogel lenses with the ocular surface.

Authors:  Semra Akkaya Turhan; Ebru Toker
Journal:  Clin Ophthalmol       Date:  2015-05-25

3.  Anterior segment optical coherence tomography angiography to evaluate the peripheral fitting of scleral contact lenses.

Authors:  Imma Gimenez-Sanchis; Beatriz Palacios-Carmen; Angel García-Garrigós; Javier Cantó-Vañó; Antonio J Pérez-Ortega; David P Piñero
Journal:  Clin Optom (Auckl)       Date:  2018-09-04

4.  Change in the geometry of positive- and negative-powered soft contact lenses during wear.

Authors:  Bartlomiej J Kaluzny; Joanna Stachura; Patryk Mlyniuk; Alfonso Jimenez-Villar; Magdalena Wietlicka-Piszcz; Ireneusz Grulkowski
Journal:  PLoS One       Date:  2020-11-09       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.